9.
Minimum Deadband
(2°F to 9°F) (1.0°C to 4.5°C)
Set the minimum separation between heat setpoint and
cool setpoint in
Auto Changeover
Mode.
FILTER
DIFF
ROOM
SET
REMOTE
FILTER
DIFF
ROOM
SET
REMOTE
11.
Minimum Cool Setpoint
(45°F to 75°F) (7°C to 24.0°C)
Adjust to control the minimum Cool set temperature allowed.
Press the or button to select.
Press the
SW6
button to advance to the next screen.
FILTER
DIFF
ROOM
SET
REMOTE
FILTER
DIFF
ROOM
SET
REMOTE
12.
Maximum Heat Setpoint
(55°F to 90°F) (13°C to 32°C)
Adjust to control the maximum Heat set temperature allowed.
Press the or button to select.
Press the
SW6
button to advance to the next screen.
FILTER
DIFF
ROOM
SET
REMOTE
FILTER
DIFF
ROOM
SET
REMOTE
8.
3
rd
Stage
Temperature Differential
(1°F to 6°F) (0.5°C to 3.0°C)
Set the number of degrees between when stage 2 turns on and
when stage 3 turns on.
Press the or button to set differential value.
Press the
SW6
button to advance to the next screen.
FILTER
DIFF
ROOM
SET
REMOTE
FILTER
DIFF
ROOM
SET
REMOTE
10.
Staged Off Outputs
Select whether the outputs for heating and cooling are staged
off independently or are satisfied simultaneously.
1 = outputs staged off independently
0 = outputs off simultaneously
Note:
For 2 compressor heat pumps and multi-stage gas/oil systems,
stage 3 is staged off independently when
SO
is set to
O
.
FILTER
DIFF
ROOM
SET
REMOTE