12
3.
2nd Stage Temperature Differential
(1°F to 5°F) (0.5°C to 2.5°C)
Note:
Not for 1010
Set the number of degrees between when stage 1 turns on and when stage 2 turns on.
Press the
or
to set differential value. Press
to advance to the next screen.
CONFIG
4.
Staged Off Outputs
Select whether the outputs for heating and cooling are staged off independently or are
satisfied simultaneously.
= Outputs off simultaneously. = Outputs staged off independently.
Press the
or
to set. Press
to advance to the next screen.
CONFIG
2.
1st Stage Temperature Differential
(1°F to 5°F) (0.5°C to 2.5°C)
Set the number of degrees between your “setpoint” temperature and your “turn on” temperature.
Press the
or
to set differential value. Press
to advance to the next screen.
CONFIG
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
1.
Temperature Scale
(F or C)
Choose Fahrenheit or Celsius.
Press the
or
to select.
Press
to advance to the next screen.
CONFIG