background image

ICI IR 640 P 

Thermal Camera 

 

                      

User’s Manual 

 

 
 
 
 
                 

 

 
 
 
 

  

 

 

Содержание IR 640 P

Страница 1: ...ICI IR 640 P Thermal Camera User s Manual...

Страница 2: ...ower off as damage may result to the thermal detector used inside Permanent damage may result CAUTION The original shipping carton should be kept for use for future transportation Do not drop shake or...

Страница 3: ...actory calibrated It is recommended that calibration be performed every 12 months CAUTION Do not open case Unit does not contain any user serviceable parts Repair should be performed by factory author...

Страница 4: ...not defined 3 3 2 Temperature measurement 18 3 3 3 Freeze and save image Error Bookmark not defined 3 3 4 Viewing stored Images 20 3 3 5 Export saved images Error Bookmark not defined 3 3 6 LCD setti...

Страница 5: ...6 7 Video capture Error Bookmark not defined 4 6 8 System settings Error Bookmark not defined 4 7 File management Error Bookmark not defined 4 7 1 Plackback Error Bookmark not defined 4 7 2 Delete Err...

Страница 6: ...palettes 11 user selectable languages 1 8 X digital zoom 10 removable spot measurements 5 areas measurements 2 lines measurements Shortcut key custom Auto focus Manual focus Bluetooth WIFI Power save...

Страница 7: ...le or Telephoto Lenses Applications Preventive maintenance Power industry Power line and power facility thermal state checking problem and defect diagnosis Electrical system Identify potential circuit...

Страница 8: ...Forest fire prevention and detection of latent ignition source Preventive detection on specific materials of auto ignition Detection of potential spark ignition sources Medical Human body surface tem...

Страница 9: ...n batteries 2 Charging dock Lithium battery charger Lens cap User manual Infrared report and analysis software system CD SD card SD card reader Network cable Mini USB to RJ45 1 2 Optional accessories...

Страница 10: ...10 2 Camera overview 2 1 Function keys 4 5 2 3 1 9 8 10 6 7...

Страница 11: ...ter adding a spot or by selecting via the A key press the Menu key to pop up the attribute box Press four navigation keys to move the spot location In line temperature measurement editing mode activat...

Страница 12: ...ss the key twice to save the image In file management press the key to choose whether delete the chosen image or video 5 Select Auto key Marked A The A or attribute button performs 3 functions a The f...

Страница 13: ...ed Key The standard configuration is to switch temperature range F1 F3 is user defined key except standard configuration it can define below functions Image playback record short press to enter image...

Страница 14: ...twork cable Mini USB to RJ45 to connect Internet 13 SD card slot Accepting standard size SD card such as supplied 8GB capacity card for device upgrade or image storage 14 Power interface External powe...

Страница 15: ...amera below the view finder Insert the battery the battery contacts must face into the battery compartment press battery in until the battery is locked in place When inserting the battery note the tri...

Страница 16: ...se of incorrect battery may result in physical or electrical damage to the instrument due to incorrect voltage or physical size difference 3 1 2 Replacing battery When battery has approximately 5 char...

Страница 17: ...ended that the battery should be charged in a set time as below Ambient temperature of 4 F 20 C to 67 9 F 20 C once every 6 months 67 9 F 20 C to 113 F 45 C once every 3 months 113 F 45 C to 149 F 60...

Страница 18: ...ears please press button A for a long time to compulsion in force 3 3 2 Temperature measurement If no measurement cursors are on screen add a measurement spot area or line by pressing MENU and selecti...

Страница 19: ...log box Spot attributes can amend emissivity distance and reference temperature When Set Ref is set as Yes the displayed values of other measurements will be their delta from this measurement Line att...

Страница 20: ...lect one reference temperature object 3 3 3 Freeze and save image There are three ways to save the image 1 Press S key to freeze the image and then select Save to save the image or select Cancel to ex...

Страница 21: ...to adjust LED screen brightness 2 Set shortcut key to LCD brightness adjustment to adjust LED screen brightness 3 3 7 Menu operating instructions Keyboard operation press the OK button to pop up the f...

Страница 22: ...interface description 4 1 1 Screen graphic interface Screen graphic interface 1 Company logo 2 Emissivity the current emissivity setting 3 Reference Temperature Fixed reference temperature 4 Result I...

Страница 23: ...ette palette bar User can choose different palettes 11 Calibration freeze indicates the calibration status or freeze status 12 Wi Fi Wi Fi is open will change along with Wi Fi signal 13 Bluetooth sele...

Страница 24: ...is adding spot adding line adding area delete taking photo record playback and main menu 4 1 3 Main menu Main Manu The main menu items display the main menu item document management temperature setti...

Страница 25: ...t each item corresponds to the content of a project the left and right keys to make changes indicates the lower menu 4 Parameter options press the left button to select a different parameter 4 2 Measu...

Страница 26: ...ave the video save format to MP4 Pressing the Enter key floating menu pops up select video and press the Enter key as shown below Recording Figure Press stop key to end the recording and return to the...

Страница 27: ...5 Preview This item is for the preview files of backup Press confirming key Pop up the floating items select preview and press confirm key and it will appear as followed Preview OSD Switch to files by...

Страница 28: ...alibration definition of shortcut key Bluetooth pattern of power saving brightness adjustment of LCD unit of temperature unit of distance external video output switch in total 8 items Switch between i...

Страница 29: ...h image playback record LED light OLED light brightness adjustment transparency adjustment and adding deleting a spot or deleting an area of choice When select shortcut key of light It will open the l...

Страница 30: ...key thermal imaging camera will screen on This function is not valid when time is set to 0 minute Time of power off If without any operation thermal imaging camera will power off to save power This f...

Страница 31: ...31 Auto off time OSD LCD brightness adjustment It is valid when changing the brightness LCD brightness adjust OSD...

Страница 32: ...stment object temperature can be set Use UP Down button to select means there is sub menu press Right Button to enter the sub menu Level Setting the Measuring Level of the thermal camera Magnification...

Страница 33: ...asuring Setting In this menu Emissivity TCorrect Distance Humidity TReflect can be set Use UP Down button to select use LEFT Right to set the value means there is sub menu press Right Button to enter...

Страница 34: ...ce temperature 4 6 4 Image settings Image Setting Menu Press OK button to call out the Image setting menu under Setting In this menu Manual Auto Enhance Mode IR transparency Alarm setting Isotherm IR...

Страница 35: ...e the camera will automatic adjust the to the range of temperature sensed in the image If select Auto Enhancement both High temp target and low temp target can be viewed in the image If Manual mode is...

Страница 36: ...Temperature Only functioned when it is enabled Alarmlink It will automatic saved when there is alarm including snapshots and video record Time Interval Set the alarmlink time interval Alarm video time...

Страница 37: ...ions IR Fusion High Temp IR fusion Low Temp and OFF Set IR Fusion High Temp when the actual temperature is higher than the temperature of IR fusion set up CCD image will be shown Vice versa 4 6 5 Netw...

Страница 38: ...ealize the communication among different segment 4 6 6 SD card management SD Card Management Figure SD Card Format Figure Press the Enter key to pop up floating panel then select Settings option to ac...

Страница 39: ...Settings option to activate the main menu selected the camera settings option Associated Pictures This function is to associate the infrared images with digital image to save the picture together Ima...

Страница 40: ...pop up Settings option to activate the main menu select System Settings item in the setup menu Users can customize the set system language time date formats time date restore the factory value items P...

Страница 41: ...l be saved Users can customize to set the year month day hour minute entries Press the left and right key to do the settings Note When left unused for a long time due to the limited internal battery p...

Страница 42: ...ameter table Recover Factory Setting Note Recover factory setting will cancel all user defined parameters System Version Info System Version Figure Display thermal imaging device model device number s...

Страница 43: ...playback File Management Figure 1 File management mode press the Enter key to pop up floating panel select Settings option to activate the main menu select the file management menu in the setup menu p...

Страница 44: ...key to exit open image and return to the measurement state Video Playback Interface Video playback interface Via the left and right key to select the play button on the status bar press the confirm k...

Страница 45: ...n buttons from left to right is as follows the former one above the next paragraph sound recording voice playback text playback 4 7 2 Delete This function is used to delete data stored in files on the...

Страница 46: ...46 File Delete Figure Note Before deletion make sure that the file is no longer needed or have backup the deleted image cannot be recovered...

Страница 47: ...of reading Whichever is greater Measurement correction Automatic manual Measurement mode Up to 10 movable spots Up to 5 movable areas maximum minimum and average temperature Movable lines Line profile...

Страница 48: ...able Battery operating time 3 hours continuous operation Battery charging mode Intelligent charger or power adaptor 12V optional to random charge Power saving Auto sleep and auto shut down External po...

Страница 49: ...led Wait for 5 seconds and reboot The camera powers off automatically Battery is out of power Change battery AutoOffTime option is enabled Set as None Battery depletion is too fast Environmental tempe...

Страница 50: ...0 21 Wrought iron Quarry faced 25 0 94 Polished 38 0 28 Nickel Oxidized 200 0 37 Stainless steel Oxidized 60 0 85 Steel Oxidized 200 0 79 Common brick Surface 20 0 93 Concrete Surface 20 0 92 Glass Po...

Страница 51: ...mperature correction table Parameter Value Emissivity 0 96 TCorrect 0 C TAmbient Temp Off Table 3 Analysis setting table Parameter Value Temp Alarm Off Alarming Temp 50 0 C Alarming Color None Isother...

Отзывы: