background image

14

Figure 4-1 - Storage tanks minimum distances to respect

4.1 - Dimensions and minimum 

distances to respect

Free space must be left around the appliance both for 

installation and maintenance, as illustrated in figure 4-1.

4 - INSTALLATION

Figure 4-2 - AGUATANK 150 tank sizes (numeric references in chapter 2.1)

Содержание COSMOGAS AGUATANK 150

Страница 1: ...UATANK 200 AGUATANK 300 AGUATANK 500 AGUATANK 750 AGUATANK 1000 INSTALLATION USE AND MAINTENANCE MANUAL FOR STORAGE TANKS READ THE MANUAL CAREFULLY AS IT CONTAINS IMPORTANT INFORMATION ON THE SAFETY I...

Страница 2: ......

Страница 3: ...e temperature probes 21 4 4 Tank drain cock installer s responsibility 23 4 5 Auxiliary exchanger on request 23 4 6 Safety valve installer s responsibility 23 4 7 Expansion tank installer s responsibi...

Страница 4: ...erson having specific technical expertise in the components of heating systems production of domestic hot water for residential use fuel gas systems and electrical system Such personnel must have the...

Страница 5: ...est products on the market Every single part is proudly built tested and assembled at the COSMOGAS plants thereby ensuring the best quality control AGUATANK XXX 150 150 litre capacity floor standing t...

Страница 6: ...AGUATANK 150 Tank main components 1 Magnesium anode 1 1 2 from 2 to 9 Fitting input output 1 1 2 from 11 to 15 Probe well 1 2 16 300 mm Inspection flange 17 Supply fitting from solar circuit 1 18 Retu...

Страница 7: ...e a cock to help drain the tank 1 Magnesium anode 1 1 2 from 2 to 9 Fitting input output 2 10 Thermometer well 1 2 from 11 to 15 Probe well 1 2 16 300 mm Inspection flange 17 Supply fitting from solar...

Страница 8: ...nents 2 MAIN COMPONENTS 1 Magnesium anode 1 1 2 from 2 to 9 Fitting input output 2 10 Thermometer well 1 2 from 11 to 15 Probe well 1 2 16 300 mm Inspection flange 17 Supply fitting from solar circuit...

Страница 9: ...COMPONENTS 1 Plug 1 1 2 from 2 to 9 Fitting input output 2 10 Thermometer well 1 2 from 11 to 15 Probe well 1 2 14 Electronic protection anode 16 300 mm Inspection flange 17 Supply fitting from solar...

Страница 10: ...ater heater hot water outlet 4 Gas inlet 5 Water heater cold water inlet 6 AGUATANK model tank 7 Tank loading pump installer s responsibility 8 Tank temperature probe in the absence of auxiliary excha...

Страница 11: ...of auxiliary exchanger place instead of part 24 9 Domestic utilities 10 EN 1487 Hydraulic safety unit to be provided by the installer 11 Domestic cold water inlet 12 13 14 15 16 17 18 19 20 Possible...

Страница 12: ...instead of part 24 9 Domestic utilities 10 EN 1487 Hydraulic safety unit to be provided by the installer 11 Domestic cold water inlet 12 Fuel shut off valve on request 13 INAIL well on request 14 INA...

Страница 13: ...temperature probe in the absence of auxiliary exchanger place instead of part 24 9 Domestic utilities 10 EN 1487 Hydraulic safety unit to be provided by the installer 11 Domestic cold water inlet 12...

Страница 14: ...espect 4 1 Dimensions and minimum distances to respect Free space must be left around the appliance both for installation and maintenance as illustrated in figure 4 1 4 INSTALLATION Figure 4 2 AGUATAN...

Страница 15: ...15 4 INSTALLATION Figure 4 3 AGUATANK 200 tank sizes numeric references in chapter 2 2...

Страница 16: ...16 4 INSTALLATION Figure 4 4 AGUATANK 300 tank sizes numeric references in chapter 2 2...

Страница 17: ...17 4 INSTALLATION Figure 4 5 AGUATANK 500 tank sizes numeric references in chapter 2 3...

Страница 18: ...18 4 INSTALLATION Figure 4 6 AGUATANK 750 tank sizes numeric references in chapter 2 4...

Страница 19: ...19 4 INSTALLATION Figure 4 7 AGUATANK 1000 tank sizes numeric references in chapter 2 4...

Страница 20: ...lation manual for its references Establish the appropriate room and position for installation keeping the following factors in mind weight and dimensions of the appliance water supply connection domes...

Страница 21: ...B C Boiler Probe D Boiler Probe E F Solar or D H W Producer or Water Heater Probe G Solar or D H W Producer or Water Heater Probe 4 INSTALLATION Figure 4 8 Probes 150 positions Figure 4 9 Probes 200 a...

Страница 22: ...H W Producer or Water Heater or Boiler Probe E F Solar or D H W Producer or Water Heater Probe G Solar or D H W Producer or Water Heater Probe AGUATANK 750 and 1000 Tank without auxiliary exchanger A...

Страница 23: ...m persons animals or objects should it intervene The appliance manufacturer cannot be held liable for this ATTENTION For the safety valve in the water heater please refer to the relevant chapter in it...

Страница 24: ...s to the correct reading of the LEDs ATTENTION There are two LEDs on the device that indicate in real time the state of protection or any malfunctions See the following table for the visual signals L1...

Страница 25: ...panel The tank is not equipped with control panel for any adjustments follow the instructions in the installation use and maintenance manual of the coupled water heater 6 5 Ignition procedure Refer to...

Страница 26: ...thickness mm 3 3 Vitrification treatment temperature C 800 800 Outer cover material PVC PVC Cover material ABS ABS Colour of the outer cover White White Colour of the cover Black Black Insulation mat...

Страница 27: ...1 1 53 1 53 1 53 1 53 Fe 360 Steel Fe 360 Steel Fe 360 Steel Fe 360 Steel 3 3 4 4 800 800 800 800 PVC PVC PVC PVC ABS ABS ABS ABS White White White White Black Black Black Black PUR PUR VLIES VLIES 5...

Страница 28: ...his declaration is compliant with the requirements of Directives Low Voltage 2006 95 EC and Electromagnetic Compatibility 2004 108 EEC The warranty number is the same as the serial number This declara...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...COSMOGAS s r l Via L da Vinci 16 47014 MELDOLA FC ITALY info cosmogas com www cosmogas com...

Отзывы: