9.  TROUBLESHOOTING 

 

PROBLEM 
 
1)  None of the electrics work. 
 
 

 

 
2)  All the electrics work except 
compressor 
 
 
 
 
3)  All the electrics work but the 
compressor “klixons” (cycles 
intermittently). 
 
 
 
 
 

 

 
 

 

 
 

 
4)  Everything appears to be running 
correctly but no ice made in the 
evaporator. 

 

 
5)  Ice cube form correctly but do not 
unstick. 
 

 

 

 

 

 

 

ICE TECH PS                                                                                                                                  Technical Service Manual

                                                                                                                                                                                                             

 

POSSIBLE CAUSES 

SOLUTION

 

 

A)  The machine is not plugged in. 

A)  Plug the machine.

B)  The line fuse has blown. 

B)  Replace fuse.

C)  The current line is wrongly 
connected in the junction box. 

C)  Check connections.

D)  The cut off micro-switch is faulty or 
wrongly adjusted. 

D)  

 

 

A)  Loose wire. 

A)  Check connections.

B)  Dirty condenser. 

B)  Clean condenser.

C)  Faulty klixon. 

C)  Replace Klixon.

D)  Faulty compressor.   

D)  Replace compressor.

 

 

A)  Voltage too low. 

A)  Check connections.
 

B)  Dirty condenser. 

B)  Clean condenser.

C)  Obstruction in air circulation 

C)  Move machine

D)  Broken Fan.  

D)  Replace com

E) Faulty electrolitic condenser of 
compressor. 

E)  Replace.

F)  Fan pressostat faulty or wrongly 
adjusted. 

F)  Adjust or replace pressostat.

G)  Broken security pressostat 

G)  Replace

H)  Water PRESSOSTAT Valve 
wrongly adjusted or faulty. 

H)  Adjust or replace.

I)   Water condenser pressostat wrongly 
adjusted or faulty. 

I)  Adjust or replace.

J)   Faulty water inlet valve. 

J)   Replace.

K)  No condensable gases in the 
system. 

K)  Purge system and charge 
refrigerant.

 

 

A)  Inefficient cooling system . (Dirty 
condenser, faulty pressostat or 
condensing water inlet valve or wrongly 
adjusted or lack of refrigerant) 

A)  Check system and 
components.

B)  Faulty hot gas valve (outlet pipe 
temperature could be an indication) 

B) Replace hot gas valve.

 

 

5)  Ice cube form correctly but do not 

A)  Hot gas valve does not open. 

A) Check valve.

B)  The lower cam micro-switch is faulty 
or wrongly connected.. 

B)  Replace micro or connect it 
correctly.

C)  Only in water condensed machines) 
Faulty pressostat or it opens too much 

C) Regulate water pressostat to 
40ºC

D)  Faulty pressostat.  

D)  

Technical Service Manual

 

 

                                                                                 

SOLUTION 

A)  Plug the machine. 
B)  Replace fuse. 
C)  Check connections. 

 Check and adjust or replace. 

A)  Check connections. 

B)  Clean condenser. 
C)  Replace Klixon. 
D)  Replace compressor. 

A)  Check connections. 

B)  Clean condenser. 
C)  Move machine 
D)  Replace compressor 
E)  Replace. 

F)  Adjust or replace pressostat. 

G)  Replace 
H)  Adjust or replace. 

I)  Adjust or replace. 

J)   Replace. 
K)  Purge system and charge 
refrigerant. 

A)  Check system and 
components. 

B) Replace hot gas valve. 

A) Check valve. 

B)  Replace micro or connect it 
correctly. 
C) Regulate water pressostat to 
40ºC-43ºC. 

 Check or adjust pressostat. 

Содержание PS 22

Страница 1: ...PROVIDE IMPORTANT INFORMATION RELATIVE TO SAFETY DURING INSTALLATION USE ICE TECH PS Technical Service Manual TECHNICAL SERVICE MANUAL 122 CAREFULLY READ THE INSTRUCTIONS CONTAINED IN THIS MANUAL SIN...

Страница 2: ...e pressostat 6 2 Fan pressostat air cooled models 6 3 Safety pressostat 7 MAINTENANCE AND CLEANING INSTRUCTIONS 8 MAINTENANCE AND CLEANING PROCEDURES 8 1 Special advise concerning R 9 TROUBLESHOOTING...

Страница 3: ...uld be accessible at all times To reduce the risk of electrical shock ALWAYS disconnect the machine BEFORE cleaning or the equipment Do not attempt to install service or modify this machine Improper u...

Страница 4: ...or motor for continuous service Tough cam motor 50 Kg cm Safety device and clutch for the water pan preventing its breakage during the upward cycle Machine stoppage and water pan protection during the...

Страница 5: ...ops and the agitator motor is connected The cam motor starts to move downwards making part of the surplus flow to the drain and dropping the ice cubes pushed by the eject plate into the storage bin Th...

Страница 6: ...as it touches the cubes so switch and switching off the machine Production will start again as soon as the cubes which detained it move or are removed Diagrams of connections and dimensions undercoun...

Страница 7: ...0 4 19 39 490x595x830 5 5 42 490x595x960 5 30 42 490x595x960 7 7 48 610x640x960 7 40 48 610x640x960 6 6 55 690x640x1080 6 41 55 690x640x1080 11 11 60 770x640x1080 11 68 60 770x640x1080 11 11 80 940x64...

Страница 8: ...9 5 19 18 27 28 29 30 22 20 19 5 19 25 27 28 29 24 22 20 19 5 24 25 27 28 25 24 22 20 22 23 25 27 26 25 24 22 20 22 23 25 28 26 25 24 19 20 22 23 30 28 26 25 18 19 20 22 31 30 28 26 15 20 25 ICE TECH...

Страница 9: ...5 26 28 29 37 35 33 32 24 25 26 28 38 37 35 33 22 24 25 26 40 38 37 35 21 22 24 25 42 40 38 37 20 21 22 24 44 42 40 38 19 20 21 22 45 44 42 40 15 20 25 ICE TECH PS 62 27 28 29 30 39 38 36 35 26 27 28...

Страница 10: ...9 30 31 32 49 47 45 44 28 29 30 31 52 49 47 45 26 28 29 30 59 52 49 47 24 26 28 29 62 59 52 49 22 24 26 28 65 62 59 52 21 22 24 26 68 65 62 59 15 20 25 ICE TECH PS 82 28 29 30 31 66 61 59 57 26 28 29...

Страница 11: ...PS Technical Service Manual ICE TECH PS 122 28 29 30 31 92 85 81 79 26 28 29 30 99 92 85 81 24 26 28 29 103 99 92 85 23 24 26 28 108 103 99 92 22 23 24 26 114 108 103 99 21 22 23 24 119 114 108 103 20...

Страница 12: ...presence of delivery personnel noting any damage on the waybill ICE TECH packing bears the Green Point on all models according to the European Directives Packaging and Waste Disposal Be sure to inclu...

Страница 13: ...has to be performed with the wooden base structure firmly placed on the ground All packaging elements plastic bags cartons etc must not be left at childr ial source of danger Place the machine where i...

Страница 14: ...a carbon filter Code NOTE You may encounter water with ALL aforementioned properties A 10 reduction in overall production may occur Connecting unit to water source water cooler units Use 1 3 m flexibl...

Страница 15: ...ve been There should be a 150 mm gap on sides and top of the machine so as to allow air to circulate This valve is factory set but may need to be adjusted if mains water pressure is very high or very...

Страница 16: ...hnical Service Manual voltage and frequency of mains supply the same as indicated on rating plate c Is drainage system working properly d Is air circulation and room temperature adequate Air cooled mo...

Страница 17: ...d closing the condenser water valve Differential is a fixed 1 kg cm2 14 Psi The valve closes at 16 Kg cm2 228 Psi which is equivalent to a water exit temperature of 38 C below this pressure it will be...

Страница 18: ...rvice Manual cooled models Pressure control operates on high pressure by starting and stopping fan Differential is fixed off pressure must be 16 kg cm2 228 Psi Low pressure values may cause gearbox ma...

Страница 19: ...iling to carry them out are not covered by the warranty Proper maintenance is essential to obtain favourable ice quality and optimum functioning of unit Frequency depends on water quality and characte...

Страница 20: ...screwdriver ICE TECH PS Technical Service Manual MAINTENANCE AND CLEANING PROCEDURES WARNING Unit should always be disconnected during maintenance cleaning water entry exit from condenser 4 Prepare a...

Страница 21: ...Once the water pan returns to its horizontal position again switch off the machine Pour 3 litres of water and one half of di caloid ICE TECH cleaner into water pan work for 20 or 30 minutes occasiona...

Страница 22: ...nd Check that the valve closes tightly on models with an automatic cleaning system Special advise concerning R 404 Refrigerant Refills and drains should be carried out at the liquid parts end of conde...

Страница 23: ...ater condenser pressostat wrongly adjusted or faulty I Adjust or replace J Faulty water inlet valve J Replace K No condensable gases in the system K Purge system and charge refrigerant A Inefficient c...

Страница 24: ...ng intermittently the capillar B Remove the dehydrator unblock capillary and replace with new dehydrator Proceed again with purge and refill 10 The tray remains in stop position A faulty connecting ro...

Отзывы: