Troubleshooting errors on Pelletizer PR750H and PR350H.
TAG NAME ID : 18
Max oil temperature exceeded.
www.icetechworld.com
| IceTech Dry Ice Technology |
Rev 2
Tag name ID 18
Max oil temperature exceeded.
1. The temperature of the hydraulic oil is to
high above 70°C (158°F).
The error cannot be reset until the
temperature has fallen below 50°C (122°F).
Check oil level.
Yes, the oil level is low.
Refill with the necesarry amount of
oil.
Reset and restart
the Pelletizer.
No, there is no problems.
Go to point 2
2. The temperature of the hydraulic oil is
to high above 70°C (158°F).
The error cannot be reset until the
temperature has fallen below 50°C
(122°F).
Check oil quality.
Yes, the oil quality is not
satisfiying. It is contaminated.
Change the hydraulic oil according to
procedure no. 14
Reset and restart
the Pelletizer.
No, there is no problem.
Go to point 3
3. The temperature of the hydraulic oil is
to high above 70°C (158°F).
The error cannot be reset until the
temperature has fallen below 50°C
(122°F).
Check oil temperature transmitter and
wire connections.
Yes, the oil temperature
transmitter is not working.
Replace the transmitter
or repair the wire
connections.
Reset and restart
the Pelletizer.
No, there is no problems.
? Contact IceTech technical support.
Содержание PR350H
Страница 1: ...User s Manual Technical file 1 2 User s manual PR350H...
Страница 2: ...User s Manual 1 User s manual PR350H...
Страница 24: ...Technical file 2 User s manual PR350H...
Страница 26: ...Table for mechanical maintenance 1 Technical file PR350H...
Страница 29: ...Procedures for maintenance and repair 2 Technical file PR350H...
Страница 31: ...Procedures for maintenance and repair www icetechworld com IceTech Dry Ice Technology Rev 1 Page 2...
Страница 35: ...Procedures for maintenance and repair www icetechworld com IceTech Dry Ice Technology Rev 1 Page 6...
Страница 89: ...Alarm list 3 Technical file PR350H...
Страница 93: ......
Страница 113: ...P I Diagram 4 Technical file PR350H...
Страница 117: ...Assembly drawings 5 Technical file PR350H...
Страница 130: ...Installation layout drawings 6 Technical file PR350H...
Страница 134: ...Page 4 of 5 16 10 2012 Rev 2 PJ BN...
Страница 138: ...Wiring diagram 7 Technical file PR350H...
Страница 140: ...Holtec Automatic A S Index...
Страница 147: ...Holtec Automatic A S EC Declaration of Conformity...
Страница 149: ...Holtec Automatic A S Maintenance...
Страница 152: ...Holtec Automatic A S Project Info...
Страница 158: ...Holtec Automatic A S Power Circuit Diagrams...
Страница 160: ...Holtec Automatic A S Control Voltage...
Страница 162: ...Holtec Automatic A S Motor Circuits...
Страница 164: ...Holtec Automatic A S Safety Circuit Diagrams...
Страница 166: ...Holtec Automatic A S PLC Reference...
Страница 172: ...Holtec Automatic A S Touchpanel Modem...
Страница 174: ...Holtec Automatic A S PLC I O...
Страница 177: ...Holtec Automatic A S PLC Digital Output...
Страница 180: ...Holtec Automatic A S PLC Output 24VDC Solenoids...
Страница 184: ...Holtec Automatic A S PLC Output 230VAC Solenoids...
Страница 187: ...Holtec Automatic A S PLC RTD Input...
Страница 189: ...Holtec Automatic A S PLC Analog Input...
Страница 193: ...Holtec Automatic A S Cableplan...
Страница 206: ...Holtec Automatic A S Bill of Components...
Страница 212: ...Datasheets 8 Technical file PR350H...
Страница 221: ...Accessories 9 Technical file PR350H...
Страница 222: ......
Страница 223: ......