Electrical requirements
Before you move your
ICER-ETTE
TM
into its final location, it is important to make sure you
have the
proper electrical connection:
•
A standard electrical supply, properly grounded in accordance with the National Electrical Code
and local codes and ordinances, is required. The
ICER-ETTE
TM
should always be plugged into
its
own
individual electrical outlet.
•
It is recommended that a separate circuit, serving only your
ICER-ETTE
TM
be provided. Use a
recep
tacle that cannot be turned off by a switch or pull chain.
•
The fuse (or circuit breaker) size should be 15 amperes for 115V and 10 amperes for 230V.
A
GFCI (ground fault circuit interrupter) is not recommended because it could be prone to nuisance
tripping.
Recommended grounding method:
For your personal safety, this
ICER-ETTE
TM
must be grounded. This
ICER-ETTE
TM
is equipped with
a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord
must be plugged into a mating 3-pronged and grounding-type wall receptacle, grounded in accordance
with
the National Electrical Code and local codes and ordinances. If a mating wall receptacle is not
avail
able, it is the personal responsibility of the customer to have a properly grounded, 3-prong wall
receptacle installed by a qualified electrician.
Electrical Shock Hazard
Plug into a grounded 3- prong outlet.
Never remove the ground prong from the plug.
Never use an adapter.
Never use an extension cord.
Failure to follow these instructions can result in fire, electrical shock
or death
INSTALLATION
L588 1222 jlc
PN:186656620
5
•
The ICER-ETTE
TM
must be installed with all electrical and water connections in accordance with all state and local
codes.
•
A standard electrical supply, properly grounded in accordance with the National Electrical Code and local codes and
ordinances, is required.
Water Connection Requirement
s
•
Always use the clip to lock the water line after insert
to the quick fitting adapter.
(see FIG 5)
•
Connect to potable water supply only
.
•
Installation of the ICER-ETTE
TM
requires a
pressurized
cold water
supply inlet of ¼
in. (6.35mm)
tubing with a shut-off
valve.
•
When plumbing the unit, 18”(45cm) of water line
extends from the back with a 1/4” (6.35mm) plastic
female compression ftting.
•
A minimum of 20 psig(0.14MPa) is required for
proper operation of the water valve.
•
Drains are not required; just a water supply.
FIG 5