NOTE: Model 84 Icemakers must have back enclosure #30 reinstalled before operating or testing unit. Unit will not
operate or test satisfactorily without enclosure in place.
POSSIBLE CAUSE
CORRECTION
1A. No AC power - check breaker.
1B. AC power switch.
1C. Compressor Relay.
1D. Module.
1E. Cold control.
2A. Compressor.
2B. Refrigerant leak in system.
2C. Fan motor.
2D. Dust clogged in condenser.
2E. Jammed fan.
2F. Refer to 1 above.
2G. Module
3A. Nonfunctioning water valve
assembly.
3B. Mold heater assembly.
3C. Water supply turned off.
3D. Icemaker module.
3E. Cold control.
3F. Bad wiring harness plug contacts.
4A. Ice mold thermostat.
4B. Icemaker module.
4C. Ejector relay.
4D. Mold and heater assembly.
4E. Bad wiring harness plug contacts.
5A. Limit switch in wire harness.
5B. Icemaker module.
5C. Power supply.
5D. Mold and heater assembly.
5E. Bad wiring harness plug contacts.
6A. Ice mold thermostat.
6B. Fan motor.
6C. Ventilation poor.
6D. Dust clogged in condenser.
6E. Too much water in mold.
6F. Ejector relay.
7A. Broken door gasket.
7B. Door left open.
8A. Solenoid valve assembly.
8B. Icemaker module.
8C. Filler tube alignment.
8D. Icemold thermostat.
1. Compressor and fan not run-
ning.
2. Icer-ette will not get cold
enough to freeze cubes in
the mold.
3. Icer-ette freezes but water
does not come into mold; no
ice production.
4. Icer-ette will freeze cubes
but will not eject them.
5. Icer-ette stops in mid-ejec-
tion cycle; compressor will
not come back on.
6. Icer-ette makes and ejects
cubes but at a very slow
rate.
7. Icer-ette frosts up inside and
has to be defrosted often.
8. Excessive accumulation of
ice; water overflows the ice
mold and runs into storage
bucket; solid block of ice.
PROBLEM
BE SURE TO READ THE FOLLOWING PARAGRAPH BEFORE ATTEMPTING ANY TROUBLESHOOTING
OR REPAIR OF ICER-ETTE UNITS.
WARNING:
It is recommended that only a qualified refrigeration technician perform service on Icer-ettes. Because of
high voltage, high pressure refrigeration, and presence of water in the unit, a person who is not technically
qualified may be subject to electric shock hazard. If the Icer-ette is wired to a junction box or otherwise direct
to the AC power supply, the appropriate circuit breaker must be turned off to cut the power to the machine.
TURNING THE ON-OFF SWITCH TO THE “OFF” POSITION DOES NOT DISCONNECT THE UNIT
FROM THE POWER SOURCE AND THE DANGER OF ELECTRIC SHOCK WILL REMAIN.
This Troubleshooting Section is to be used only as a guideline to assist in determining any problem. Raritan does not
guarantee that the recommendations or corrections listed below will correct the problem.
1A. Turn on breaker to restore power.
1B. Check for loose connections. Replace switch if
needed.
1C. Replace Compressor Relay.
1D. Replace icemaker module.*
1E. Replace cold control.*
2A. Return to Raritan for compressor replacement.
2B. Contact Raritan Technical Support.
2C. Replace fan motor.*
2D. Clean Condenser (see maintenance section).
2E. Straighten fan brackets.
2F. Refer to 1A, B and C.
2G. Replace icemaker module.*
3A. Clean or replace solenoid valve assembly.
3B. Contact Raritan Technical Support.
3C. Provide pressurized water.
3D. Replace icemaker module.
3E. Replace cold control.
3F. Contact Raritan Technical Support.*
4A. Replace ice mold thermostat.*
4B. Replace icemaker module.*
4C. Replace ejector relay.
4D. Replace icemaker module.*
4E. Contact Raritan Technical Support.*
5A Contact Raritan Technical Support.*
5B. Replace icemaker module.*
5C. Check connections.
5D. Replace icemaker module.
5E. Contact Raritan Technical Support.*
6A. Replace ice mold thermostat.*
6B. Replace fan motor.*
6C. Check installation section.
6D. Clean condenser (see maintenance section).
6E. Contact Raritan Technical Support.
6F. Replace ejector relay.
7A. Replace door gasket.
7B. Defrost as needed.
8A. Replace solenoid valve assembly.
8B. Replace icemaker module.*
8C. Adjust to prevent splash over.
8D. Replace icemold thermostat.*
TROUBLESHOOTING