3
Air path for exhaust
and fresh air intake
must be unrestricted!
Recirculation between
fresh air intake and
exhaust air must be
prevented.
FIG. #1 Ventilation
IN
OUT
Model 85
IN
OUT
Model 84
MOUNTING
Required Cabinet Opening:
Model 84: 14 3/8" W x 18 1/2"H
Model 85: 14 3/8" W x 24 5/8"H
WARNING: If rubber feet are removed from the
bottom of 85 series units, the mounting screws
must be reinstalled into the bottom of the cabinet
to avoid damage to components mounted to the
base pan.
If unit is to be built-in, 3/4" (2cm) or more must be
allowed behind the unit for water line and plug
clearance for proper operation. Built-in units are
designed for zero clearance at the top and each side
of the unit. Fan-forced condenser cooling is used.
This requires air circulation through lower section of
unit (see Fig. #1). If Icer-ette is to be installed behind
closed doors, contact Raritan Technical Support.
CAUTION: Any restriction of airflow or
ventilation will disrupt normal operation of the
unit, resulting in damage to components and
voids warranty.
Unit must sit on a secure level surface. Mounting
flange must NOT be used to support the unit's
weight.
When installing the unit it should be noted that some
servicing requires access to the rear of the unit and
that
the unit must be readily removable
should
servicing be necessary.
When mounting unit within cabinetry, make sure
that the door has the desired range of motion. All
doors are hinged on the right (facing the unit) but
may be reversed in the field.
PLUMBING
A minimum of 22 P.S.I. (152kPa) is required for
proper operation of the water valve (see #26, page 4).
When plumbing Icer-ette, 18" (45cm) of water line
extends from the back with a 1/4" plastic female
compression fitting. Drains are not required; just a
water supply.
WIRING
WARNING: HAZARD OF ELECTRIC SHOCK
- Never use extension cords or plug adapters to
power unit. Never remove the ground prong
from the plug.
Power Requirements:
120 volts 60 HZ AC
(alternating current); a three-wire cord with grounded
plug is supplied,
OR:
240 volts 50 HZ AC
(alternating current), supplied with Euro-plug.
INSTALLATION
BOTTOM FLANGE INSTALALTION
MODEL 85/84B
1. Loosen top two grille
screws
2. Remove bottom two
grille screws
3. Place bottom trim
flange between grille
and cabinet.
4. Align holes and install
bottom grille screws
MODEL 85E
Once unit is installed in cabinet
1. Attach trim spacer to bottom flange
2. Slide bottom flange in place.
3. Secure with 2 screws.