Standard Warranty Policy 

 
 
Ice Qube, Inc. ("

Ice Qube

") warrants that the products manufactured by Ice Qube (the "

Products

") are free of defects in material and workmanship which impair the 

operation  of  the  Products,  under  normal  and proper  use and  service,  for a period  of  one  (1)  year  from the  date  of  shipment  FCA  from  Ice  Qube’s  facility  located  in 
Greensburg, Pennsylvania (the "

Standard Warranty

").   

 
In order for this Standard Warranty to apply, the Product(s) must be installed and operated according to and consistent with the following conditions: 
 

 

Operation within the rated voltage on the label of the Product; 
 

 

Frequency variation no greater than +/- 3 HZ from rated frequency on the label of the Product; 
 

 

Ambient temperature must not exceed operating temperature range on the label of the Product; 
 

 

Maximum cooling capacity not to exceed rating (BTU/HR) as rated on the label of the Product; and 
 

 

The Product must be installed, maintained and operated consistent with the terms and conditions set forth in the operation manual. 

 

THIS STANDARD WARRANTY DOES NOT COVER THE FOLLOWING

 

 

Ice Qube assumes no liability beyond the repair or replacement of its own Products.  In no event shall Ice Qube be liable for any incidental, special, indirect, 
consequential or similar damages incurred by any purchaser, owner, possessor, assignee or successor in interest or any other third party having any interest in 
any Product as the result of any breach of this Standard Warranty, including but not limited to loss of profit or revenues, damages for loss of use of the Products, 
damage to property, both real and personal, claims of third parties, including personal injury or death on account of use of the Products or failure of Ice Qube 
to warn against or instruct on or adequately warn against or instruct on, the dangers of the Products or the safe and proper use of the Products, whether or not 
customer has been advised of the potential for such damages. 
 

 

Ice Qube's total liability for customer's claims from any cause whatsoever, whether arising under contract, warranty, tort (including negligence), strict liability, 
products liability or any other theory of liability, will be limited to the lesser of customer's actual damages or the price paid by customer to Ice Qube for the 
Products (not including applicable taxes, duties and freight charges) that are the subject of customer's claim. 
 

THE WARRANTY SET FORTH HEREIN IS STRICTLY LIMITED TO ITS TERMS AND IS IN LIEU OF ALL OTHER WARRANTIES, GUARANTEES, EXPRESS 
OR IMPLIED, ARISING BY OPERATION OF LAW, COURSE OF DEALING, CUSTOM, USAGE OF TRADE OR OTHERWISE, SPECIFICALLY EXCLUDING 
ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE. 

 

1.

 

The warranty and remedies for breach of warranty provided for in this Standard Warranty extend only to the original installation and do not cover, and Ice Qube 
will neither assume responsibility, nor be liable, for the following:  

 

 

misapplication of its Products or the erroneous selection of an inappropriate Product by a non-authorized Ice Qube representative;    
 

 

use of the Product for other than its designed purpose or operating conditions; 
 

 

operation  or  storage  in  harsh,  oily,  corrosive  or  other  abnormal  environments  without  the  proper  filtration,  sealing,  protective  coatings  and/or  weather 
protection; 
  

 

damage to the hermetic system resulting from continuous operation with dirty or clogged air filters or improper or negligent maintenance; 
 

 

use of refrigerant other than designated on the label of the Product; 
 

 

customer modification or abuse; 
 

 

shipping damage or other accidental damage (It is Ice Qube’s standard policy that freight claims are the responsibility of the customer if the Product is not 
refused at delivery); 
 

 

repair, damage or service of the Product caused by anyone except personnel authorized by Ice Qube; 
 

 

cracked or broken hermetic tubing, brazed joints or other internal damage caused by shipping or mishandling; 
 

 

damage caused by shipping units attached to an enclosure; 
 

 

any and all damage, breakage, malfunction or other like conditions or defects resulting from noncompliance with the standard  operation, care, installation, 
maintenance and use of the Product as set forth in the operation manual for such Product; 
 

 

any cause beyond the control of Ice Qube, including without limitation conditions caused by movement, settlement or structural defects of the environment in 
which the Products are installed; 

Содержание IQ700HE

Страница 1: ...r Nonhazardous Locations OPERATION AND INSTALLATION MANUAL IMPORTANT PLEASE READ this manual and follow the instructions for safe and satisfactory installation and operation of this system Keep this manual for future reference Some information may not apply to all systems ...

Страница 2: ... 9 Fan Speed Controller Ord Loc Only 9 Maintenance 11 Trouble Shooting 11 Schematic Wiring Diagram 13 Specification Drawings 14 IQ700HE 14 IQ800HE 15 IQ900HE 16 IQ2200HE 17 IQ6100HE 18 IQ7400HE 19 IQ10000HE 20 Gasket and Cutouts 21 IQ700 800HE Gasket and Cutout 21 IQ900HE Gasket and Cutout 22 IQ2200HE Gasket and Cutout 23 IQ6100HE Gasket and Cutout 24 IQ7400HE Gasket and Cutout 25 IQ10000HE Gasket...

Страница 3: ...everal systems that function simultaneously to maintain environmentally friendly conditions for your equipment within the enclosure The three main thermal related systems that we employ are the closed loop cold air supply stream the heat rejection air stream and our MSCCT Multi Surface Cold Core Technology heat exchanger Within this system are only two moving parts They are maintenance free fans b...

Страница 4: ...xchanger will be 1 Operation manual 2 Mounting hardware 3 Standard master warranty 4 Enclosure gasket Storage The storage space temperature should be in the range of 40 to 85 C 40 to 185 F in a non condensing environment CONDITIONS OF ACCEPTABILITY When installed in the end use equipment the following considerations are to be examined 1 The maximum operating temperature of the devices while subjec...

Страница 5: ... point Factory set points Enclosure 70 F Ambient 90 F Fan speed controller option available for Ord Loc Only 4 After completing the above check point the Ice Qube TMS is ready to be mounted to your enclosure Preparing the Enclosure Please read entire section before beginning installation The Ice Qube TMS has been designed to be light in weight for easy installation These units have been designed w...

Страница 6: ...ounting studs through the 3 8 9 5mm or 1 2 12 7mm depending on model holes in your enclosure and check to see that all openings are aligned 3 After checking that all openings and bolt holes are in alignment assemble and tighten the 2 or 4 20 nuts and 2 4 6 or 8 depending on model 20 x 1 bolts supplied with you Ice Qube TMS by hand Check to ensure gasket will properly seal the Ice Qube TMS to your ...

Страница 7: ...Check that wire routing to the terminal box will not interfere with or become damaged by other components Electrical Installation 1 Check that the heat exchanger designated power supply is de energized and locked out 2 Locate terminal box on enclosure side of heat exchanger Depending on option ordered terminal box cover will either have a power cord exiting or a terminal block beneath the cover a ...

Страница 8: ...8 Rev 6 Figure 3 Terminal Cover Figure 4 Terminal Block optional ...

Страница 9: ...ve or hot and is negative or neutral the power connection is polarity sensitive Be careful when handling or adjusting the controller as all components and circuitry are at line voltage except for the alarm outputs which are dry contacts When power is applied to the heat exchanger the fan speed controller will automatically sequence through a diagnostic procedure that will check the operation of th...

Страница 10: ...is set at 10 F from the factory Differential 1 2 3 5 5 Off Off Off Off 10 Off On Off On 15 On Off On Off 20 On On On On Each fan has an LED that will indicate the status of the fans Normally with power supplied to the controller and the fans not operating the LED s will blink at a rate of 1 pulse every 2 seconds When the fans begin to operate the LED s will blink 1 pulse per second As the fan spee...

Страница 11: ...excess water from the filter before returning it to the system Replace the filter if it shows signs of deterioration See website for air filter cleaning demonstration at http www iceqube com ice qube tv 2 Cooling System Cabinet The heat exchanger cabinet may also need to be cleaned occasionally To clean the heat exchanger cabinet simply wipe it with a damp lint free cloth A mild soap solution may ...

Страница 12: ...erating Yes No Is the enclosure door closed tightly Yes No Are all of the gaskets in place Yes No Has the ambient warm air stream filter been cleaned or changed recently If applicable Yes No Is the system mounted level on the enclosure Yes No Is there adequate space within the enclosure for airflow Yes No Is there adequate space around the heat exchanger for airflow Yes No Has the enclosure popula...

Страница 13: ...13 Schematic Wiring Diagram Figure 6 ...

Страница 14: ...14 Rev 6 Specification Drawings IQ700HE Figure 7 ...

Страница 15: ...15 Rev 6 IQ800HE Figure 8 ...

Страница 16: ...16 Rev 6 IQ900HE Figure 9 ...

Страница 17: ...17 Rev 6 IQ2200HE Figure 10 ...

Страница 18: ...18 Rev 6 IQ6100HE Figure 11 ...

Страница 19: ...19 Rev 6 IQ7400HE Figure 12 ...

Страница 20: ...20 Rev 6 IQ10000HE Figure 13 ...

Страница 21: ...21 Rev 6 Gasket and Cutouts IQ700 800HE Gasket and Cutout Same Gasket and Cutout for IQ700HE and IQ800HE Figure 14 ...

Страница 22: ...22 Rev 6 IQ900HE Gasket and Cutout Figure 15 ...

Страница 23: ...23 Rev 6 IQ2200HE Gasket and Cutout Figure 16 ...

Страница 24: ...24 Rev 6 IQ6100HE Gasket and Cutout Figure 17 ...

Страница 25: ...25 Rev 6 IQ7400HE Gasket and Cutout Figure 18 ...

Страница 26: ...26 Rev 6 IQ10000HE Gasket and Cutout Figure 19 ...

Страница 27: ...bility or any other theory of liability will be limited to the lesser of customer s actual damages or the price paid by customer to Ice Qube for the Products not including applicable taxes duties and freight charges that are the subject of customer s claim THE WARRANTY SET FORTH HEREIN IS STRICTLY LIMITED TO ITS TERMS AND IS IN LIEU OF ALL OTHER WARRANTIES GUARANTEES EXPRESS OR IMPLIED ARISING BY ...

Страница 28: ...mes be deemed to be non binding Such advice does not relieve customer from the obligation and customer accepts full responsibility to confirm for itself the suitability of the Products for their intended purpose s Remedies Customer s sole and exclusive remedy and Ice Qube s only obligation for breach of warranty hereunder shall be at Ice Qube s option in its sole discretion to i repair or replace ...

Страница 29: ...29 Rev 6 Notes ...

Отзывы: