INSTALLATION OF D200 (S1FD) DOOR STATION
The door station is normally mounted at a height from the floor of approximately 1400 to 1500mm.
If a surface mount back box is being used, feed the cable through the back box and secure the back
box to the wall using screws and appropriate wall plugs.
If a recess mount back box is being used, a brick is usually removed and a metal wall box fitted.
(Part Number: 100976)
Pull the cable through the metal wall box and the door station back box and secure the back box to
the metal wall box using screws.
Fit the terminal block(s) to the PCB and terminate wires from the cable as per the DOOR
STATION TERMINATION section below.
Secure the metal plate to the back box using only one screw initially as programming and volume
level adjustments will most likely need to be made to the PCB before the unit is finally sealed.
After the unit has been programmed and the volume levels adjusted, the installation can then be
completed.
Secure the metal plate to the back box using the PT screws provided.
Fit the optional weather shield if required (see part numbers below)
Fit the optional trim plate in position if required.
Finally clip the plastic front onto the back box.
Note: Fitting of a weather shield is recommended where the station may be exposed to weather.
Recommended weather shield is: P/N 100962
10WAY BLOCK
POS
Connects to Corresponding terminal at Master
NEG
Connects to Corresponding terminal at Master
TC
Connects to Corresponding terminal at Master
VLC
Connects to corresponding VLC terminal at the Master depending on Door Station number
*
See Note 1
SHLD
Not Connected (except where shielded cable used)
COM1
Connects to Corresponding terminal at Master
COM2
Connects to Corresponding terminal at Master
CH –
Switched negative for Chime Relay
+
Positive 12V for Lock Relay and Chime Relay
LK –
Switched negative for Lock Relay
2WAY BLOCK
V SIG
Connects to corresponding VID terminal at the Master depending on Door Station number
*
See Note 1
SHLD
Connects to corresponding GND terminal at the Master depending on Door Station number
*
See Note 1
Note 1: Each door station becomes Door 1, 2, or 3 depending on which VLC terminal it is connected to at the master
Depending on the number of Door stations fitted, they should be connected to the master
starting at VLC1, then VLC2 etc
V SIG and SHLD from each door station connects to the corresponding camera input at the master
i.e. CAM1 for Door 1, CAM2 for Door 2 and CAM3 for Door 3
Note 2: Relays used for Lock Output and Chime output should have a coil Resistance of 240 ohm or greater
Relays to control lock outputs can be fitted at master or at door stations
The Lock and Chime Controlled outputs are for optional applications
Note 3: For Room Station Only systems, VLC of all door stations connects to VLC of the room station to which the
power supply is connected
Содержание System One M200
Страница 14: ...10 10 BLOCK DIAGRAMS ...
Страница 26: ...22 22 Powering Electric Lock from Door Station Powering Electric Lock from Separate Supply ...
Страница 43: ...39 NOTES ...
Страница 44: ......