in operation to circulate the water in order to rinse
the entire water system.
10. Do it twice so to be sure no more traces of
descaling solution remains into the sump.
11. Pour on the upper side of the evaporator
platen fresh water with a capfull of disinfectant
solution then turn again the machine in cleaning
mode so to sanitize all the water system for
approx. 10 minutes.
NOTE.
Do not mix descaling with disinfectant
solution to avoid the generation of a very
aggressive acid.
12. Flush out the sump reservoir then turn the
program selector on RESET/HI TEMPERATU-
RE position and immediately afterward to
FREEZING OPERATION.
NOTE.
By setting the selector on RE-SET
first and then to FREEZING OPERATION
the ice maker will perform the 5 minutes
WATER FILLING phase i.e. the water inlet
solenoid valve opens to allow the incoming
water to rinse again the water system and to
properly fill-up the sump reservoir for the
next freezing cycle.
13. Place again the evaporator cover and the
unit service panels.
14. At completion of the freezing and harvest
cycle make sure of proper texture and clearness
of the ice cubes and that, they do not have any
acid taste.
ATTENTION. In case the ice cubes are
cloudy-white and have an acid taste, melt
them immediately by pouring on them
some warm water. This to prevent that
somebody could use them.
15. Wipe clean and rinse the inner surfaces of
the storage bin.
REMEMBER.
To prevent the accumulation
of undesirable bacteria it is necessary to
sanitize the interior of the storage bin
with an anti-algae disinfectant solution
every week.
WARNING. The Ice Machine Cleaner
contains Phosphoric and Hydroxyacetic
acids.
These compounds are corrosive and may
cause burns if swallowed, DO NOT indu-
ce vomiting. Give large amounts of water
or milk. Call Physician immediately.
In case of external contact flush with
water. KEEP OUT OF THE REACH OF
CHILDREN
4.
Take out all the ice cubes stored into the bin
in order to prevent them from being contaminated
with the cleaning solution then flush out the water
from the sump reservoir by removing the plastic
plug.
5.
Remove the evaporator cover then slowly
pour onto the evaporator platen the cleaning
solution. With the help of a brush dissolve the
most resistant and remote scale deposits in the
platen.
6.
Set the program selector head on
CLEANING/RINSING (Fig. 8).
NOTE.
With the system in CLEANING/
RINSING mode the water pump is the only
component in operation to circulate the
cleaning solution in the entire water system.
7.
Let the unit to remain in the CLEANING/
RINSING mode for about 20 minutes then turn
the program selector on STAND BY again.
8.
Flush out the cleaning solution from the
sump reservoir then pour onto the evaporator
cavity two or three liters of clean potable water to
rinse the mold cups and the platen.
If necessary remove the water spray platen to
clean it separately as per step 3 of paragraph B.
9.
Turn again the program selector on
CLEANING/RINSING. The water pump is again
FIG. 8