Icel Manaus MG-3010 Скачать руководство пользователя страница 2

1. Summary

The newly style of Digital Insulation Resistance Tester is MG-

3010. It has fashionable design and improved electronic circuit, so
that has more fully function, higher precision, easier operation.

The output testing voltage can be selected in 250V/500V/1000V

for deferent measurement. Resistance range can touch

.

2000M

Ω

Alternating voltage also can be tested.

This tester apply for all kinds of electric equipment and

insulation materials such as transformer, electromotor, cable,
switch appliance, etc.It is a perfect electrical testing meter.

2 Safety notice

.

(1)Read this Operation Manual carefully before use it.
(2)This meter is designed in accordance with ICE publication
1010, pollution degree

and installation category (over voltage

category)

.

(3)Shouldn't use it before close the back lid cause of the danger of
electroshock.
(4)Check the insulation skin of the test lead.
(5)Don't rotate switch when testing.
(6)When seeing “

” on the LCD, means battery is low. Please

replace battery to ensure accurately testing.

Содержание MG-3010

Страница 1: ...Contents 1 Summary 2 Safety notice 3 Feature 4 Technique speci cation 5 Panel map 6 Operating 7 Maintenance 8 Accessories MG 3010 Digital Insulation Resistance Tester Operating Manual...

Страница 2: ...tric equipment and insulation materials such as transformer electromotor cable switch appliance etc It is a perfect electrical testing meter 2 Safety notice 1 Read this Operation Manual carefully befo...

Страница 3: ...t current is over 1 5mA 8 Range 0 20 auto range 00M 9 Perfect circuit protect 10 Size of LCD 67 28mm Height of character is 20mm 11 Power R6P AA 1 5V 6 12 Size 150 100 70mm 13 Weight 680g Including ba...

Страница 4: ...MG 3010 200M 2000M 5 readings 5 digits...

Страница 5: ...OP 3 Data holding button Hold 4 Rotary switch 5 E EARTH socket 6 G socket leakage current for insulation input for ACV 7 ACV input 8 L LINE socket 2000M MAX 2000M MAX Test V Sel Test V Sel G MAX 700V...

Страница 6: ...e destroyed d Be sure to con rm the position of rotary switch and the connection of measuring lead with the tester before starting the measurement e When start the high voltage button There is a high...

Страница 7: ...s the button once again to turn the power o When the power is turned on measuring high voltage is generated measurement is started and LED on the panel will light the value will be showed on the LCD T...

Страница 8: ...turn o the power before replace battery Please open the lid and t the new battery c Take out battery and put it in the place where dry and airiness if the meter will be unused for long term d Don t ch...