Adjustments
CD40030/CD40022
Page
15
The dispenser is preset at the factory. Adjustments are rarely needed.
Agitation Time Recommandations:
The standard time is 3 seconds on every
6 hours. Adjust to agitate more frequently
if the unit is installed in a low
temperature environment. However, if
the ice being dispensed is in small
crushed pieces, adjust to agitate less
frequently.
Water Filler
The water faucet can be adjusted for
flow. There is a screw adjustment in the
top of the valve body. Loosen the
locknut and rotate the screw CW for less
water flow. Be sure to re-tighten the
lock-nut or a water leak may develop.
Coin or Token Operation
The standard time for vending is pre set at
20 seconds on the Vend Ready Timer.
This includes time allowed for vending and
customer activation. If necessary, adjust
this timer to a higher number to deliver
more ice, or a smaller number for less ice.