Ice-O-Matic Gourmet UCG Series Скачать руководство пользователя страница 4

UCG GOURMET SERIES UNDERCOUNTER 

pg. 4 

b.

 

Minimum  water  inlet  temperature  of  40˚F  (5˚C)  and  maximum  water  inlet
temperature of 90˚F (35˚C).

c.

 

Well ventilated location.

d.

 

Service access: adequate space must be left for all service connections through the
rear of the ice maker.  A minimum clearance of 6” (15cm) must be left at the sides of
the unit for routing air drawn into and exhausted out of the compartment to maintain
proper condensing operation.

2. Level the unit in both the left to right and front to rear directions.

D. 

ELECTRICAL CONNECTIONS 

See data plate for current requirements to determine wire size to be used for electrical connections. 
All Ice‐O‐Matic ice makers require a solid earth wire.  They are supplied from the factory completely 
pre‐wired and require only electrical power connections to the rear of the unit.    Make  sure  the 
ice  maker  is  connected  to  its  own  circuit  and individually fused (see data plate  for fuse size).  
The maximum allowable voltage variation should  not  exceed  ‐10%  and  +10%  of  the  data plate 
rating.    Low  voltage  can  cause  faulty  functioning  and  may  be  responsible  for  serious  damage  to  the 
overload  switch  and  motor  windings.    Check  voltage  on  the  line  and  the  ice  maker’s  data  plate 
before connecting the unit. 

E. 

WATER SUPPLY AND DRAIN CONNECTIONS 

GENERAL 

When choosing the water supply for the ice maker consideration should be given to: 

a. Length of run
b. Water clarity and purity
c. Adequate water supply pressure

Since water is the most important single ingredient in producing ice, the three items listed above are 
extremely significant.  Low water pressure, below 14 psi (1 bar), may cause malfunction of the ice 
maker.  Water containing excessive minerals will tend to produce cloudy ice cubes, in addition to scale 
build‐up on parts of the water system. 

WATER SUPPLY 

Connect the ¾” male fitting of the solenoid water inlet valve, using the flexible tube supplied, to the 
cold‐water  supply  line  with  regular  plumbing  fitting  and  a  shut‐off  valve  installed  in  an  accessible 
position between the water supply line and the unit.  If water contains a high level of impurities, it is 
advisable to consider the use of an appropriate water filter. 

NOTE: All external wiring should conform to national, 
state, and local standards and regulations. 

Содержание Gourmet UCG Series

Страница 1: ...45 UCG 65 UCG 85 UCG 105 UCG 135 UCG 165 Installation and Service Manual Ice O Matic 11100 E 45th Ave Denver Colorado 80239 1 866 PURE ICE Part Number 9081522 02 Revision 03 21 UCG GOURMET SERIES UND...

Страница 2: ...UCG GOURMET SERIES UNDERCOUNTER pg 2...

Страница 3: ...damage Notify the carrier of any concealed damage 5 Check that refrigerant lines do not rub against or touch other lines or surfaces and the fan blade moves freely 6 Check that the compressor fits sn...

Страница 4: ...Low voltage can cause faulty functioning and may be responsible for serious damage to the overload switch and motor windings Check voltage on the line and the ice maker s data plate before connecting...

Страница 5: ...proper flow of the drained water as in case of poor drainage the water ranning out from the condenser may inopportunely flow through the unit drain tubing into the ice storage bin F FINAL CHECK LIST...

Страница 6: ...the electrical circuit to the water inlet valve and to the hot gas valve C Switch ON the power line disconnect switch Unit will start up in water filling phase mode During this phase the components e...

Страница 7: ...hermostat or cube size control changes its contacts the freezing cycle ends and starts the defrost or harvest cycle E On models UCG 135 165 freezing cycle is completed through an electronic timer ener...

Страница 8: ...45 65 85 105 the length of the freezing cycle can be modified by turning the knob of the cube size control or evaporator thermostat located in frontofthe machineuntilthedesiredsizeisachieved if the t...

Страница 9: ...defrost or harvest cycle hold a handful of ice cubes against the bulb of the storage bin thermostat the icemaker switch OFF in about one two minutes Take out the ice from the storage bin thermostat Th...

Страница 10: ...UCG GOURMET SERIES UNDERCOUNTER pg 10...

Страница 11: ...compressor and through the suction line In both the accumulator and the suction line it exchanges heat with the refrigerant flowing into the capillary tube warmer before it is sucked in the compressor...

Страница 12: ...sig on the models UCG45 65 85 and 0 85 and 0 2 0 3 bar 3 4 psig on models UCG105 135 165 with the cubes fully formed in the cup molds The total length of the freezing cycle ranges from 23 to 25 minute...

Страница 13: ...and the second water cooled condenser by a specific hi pressure control HOT GAS SOLENOID VALVE The hot gas solenoid valve consists basically in two parts the valve body and the valve coil During the...

Страница 14: ...arallel to the water pump and it operates continuously only during the freezing cycle keeping the proper head press circulating air through the condenser fins On UCG135 165 the operation of fan motor...

Страница 15: ...the entire defrost harvest cycle with a factory pre set times The first key 1 replaces the Compressor Switch used on the previous electro mechanical version factory setting is ON position to energize...

Страница 16: ...er cooled version only This valve controls the head pressure in the refrigerant system by regulating the flow of water going to the condenser As pressure increases the water regulating val ve opens to...

Страница 17: ...ure Move the unit in a more suitable place Cubes too small Freezing cycle too short Review setting of DIP SWITCH keys Capillary tube partially restricted Blow charge add new gas drier after evacuating...

Страница 18: ...cuu pump Hot gas solenoid valve leaking Replace valve Undercharge of refrigerant Charge to data plate indication Discharge head pressure too high See incorrect discharge pressure Poor harvest Restrict...

Страница 19: ...not perform any adjustment until the ice making system has progressed through several complete freeze and harvest cycles in order to observe the size and quality of ice cubes and whether or not the cu...

Страница 20: ...UCG 45 65 85 105 WIRING DIAGRAM AIR WATER COOLED 230 50 60 1 pg 20 UCG GOURMET SERIES UNDERCOUNTER...

Страница 21: ...UCG 135 165 WIRING DIAGRAM ELECTRONIC TIMER VERSION 230 50 60 1 pg 21 UCG GOURMET SERIES UNDERCOUNTER...

Страница 22: ...Page 22...

Страница 23: ...and to get current warranty information Refer to it for applicable coverage In general warranty covers defects in material or workmanship It does not cover maintenance corrections to installations or...

Отзывы: