Ice-O-Matic GEMD270A2 Скачать руководство пользователя страница 11

E.

Check for the correct CUT-OUT and

CUT-IN  of the float reservoir water level sen-
sors
 by shutoff the valve on the water supply
line.
This will cause a gradual decrease of the water
level in the float reservoir and as soon as the
level gets below the sensors, the flaker stops to
operate and the 5thYELLOW warning LED will
glow to signal the shortage of water (Fig.5).

NOTE. The water level sensor detects the
presence of sufficient water in the float
reservoir and confirms it to the micro
processor by maintaining a low voltage
current flow between the two sensors using
the water as conductor.

WARNING. The use of de-mineralized
water (water with no salt content) having
an electrical conductivity lower than 30

µ

S, will cause the ability of the water

sensors to vanish with the consequent
CUT-OUT of the flaker operations and the
glowing of the YELLOW LED of shortage
of water, even though that water is indeed
in the reservoir.

After this, open the water supply line shutoff
valve to fill up again the float reservoir, the 5th
YELLOW LED
 goes off while the 2nd RED LED
starts blinking
.
After 3 minutes the unit resumes its total operation
with the immediate start-up of the gear motor
and, 2 seconds later, of the compressor.

F.

 

Check for the correct operation of the

 

electronic eye for the ice bin level control, by

 

placing one hand between the sensing “eyes”

 

located in the ice spout, to interrupt the light

 

beam.
This interruption will cause an immediate blink of

 

the 

6th

 YELLOW LED and after about 6 seconds

 

causes the shutoff of the unit with the simulta-
neous lighting of the same YELLOW LED

 

signalling the full bin situation (Fig.6).
Allow the resumption of the light beam previously

 

interrupted and after about 6 seconds with

 

YELLOW LED blinking fast, the flaker will resume

 

-

 

through the 3 minutes STAND-BY period - the

 

ice making process with the extinguishing of the

 

YELLOW LED.

NOTE. The ICE LEVEL CONTROL (INFRA-
RED SYSTEM) 
is independent of the tempe-
rature however, the reliability of its detection
can be affected by dirt and scale sediment
which may deposit directly on the light source
and on the receiver.
To prevent any possible ice maker
malfunction, due to negative affection of the
light detector, it is advisable to follow the
instructions for the periodical cleaning of
the light sensor
 elements as detailed in the
MAINTENANCE AND CLEANING PRO-
CEDURES.

FIG. 4

STEADY

TOO HI CONDENSING TEMPERATURE

FIG. 5

NO WATER

FIG. 6

BLINKING - FLASHING SLOW

INFRARED BEAM CUTTED WITH MACHINE IN OPERATION

STEADY

MACHINE OFF AT BIN FULL

BLINKING - FLASHING FAST

INFRARED BEAM ON AFTER THE TRIPPING OFF AT BIN FULL

GEMD270A

Page

 

9

OPERATING INSTRUCTIONS

Содержание GEMD270A2

Страница 1: ...GEMD270A2 PEARL ICE ICE WATER DISPENSER MODELS GEMD270A2 Installation and Service Manual Ice O Matic 11100 E 45 th Ave Part Number 9081407 01 Revision 03 23 21 Denver Colorado 80239 1 866 PURE ICE...

Страница 2: ...SERVICE PARTS MANUAL 22 INCH WIDE ICE SERIES CUBERS MODEL ICE0320 ICE0520 Includes 50Hz Units ICE O Matic 11100 East 45th Ave Denver Colorado 80239 Part Number 9081297 01 PD04 02 Rev1 05...

Страница 3: ...ONNECTIONS Page 5 WATER SUPPLY AND DRAIN CONNECTIONS Page 6 FINAL CHECK LIST Page 7 OPERATING INSTRUCTIONS Page 8 INITIAL START UP CONTINUED Page 9 SETTING THE DISPENSING SELECTOR Page 11 PRINCIPLE OF...

Страница 4: ...S GEMD270A Page 2 Model Cond unit Cabinet Size Finish Comp HP Ice bin cap GEMD270A Air 34 13 32 high x 15 9 32 wide x 26 7 64 deep S Steel 3 8 12 lb Basic electrical Amps Watts Amps fuse 115 60 1 6 55...

Страница 5: ...CABINET DIAGRAMS GEMD270A Page 3...

Страница 6: ...including Model and Serial Number taken from the data plate Forward the completed self addressed registration card to Ice O Matic factory LOCATION AND LEVELING WARNING This Ice Dispenser is designed...

Страница 7: ...e machine is connected to its own circuit and individually fused see data plate for fuse size Not Connected to a G F I outlet The maximum allowable voltage variation should not exceed 10 and 10 of the...

Страница 8: ...ar WATER SUPPLY Connect to the male water inlet fitting using the supplied fitting to the cold water supply line A shut off valve should be installed in an accessible position between the water supply...

Страница 9: ...en checked to ensure a flowing water pressure of at least 20 psi 7 Check all refrigerant lines and conduit lines to guard against vibrations and possible failure 8 Has the unit been sealed to the coun...

Страница 10: ...the system or inoperativecompressororevaporatorsensor itis necessarytopushtheRE SETBUTTON or De engerizeandre engerizeunit Theunit before resumingthetotaloperation willgothroughthe usual3minutesSTAND...

Страница 11: ...compressor F Check for the correct operation of the electronic eye for the ice bin level control by placing one hand between the sensing eyes located in the ice spout to interrupt the light beam This...

Страница 12: ...eneous glowing of the YELLOW LED signalling the Full Bin situation NOTE The interruption of the light beam between the two light sensors is immediately signalled by the blinking of the 6th YELLOW LED...

Страница 13: ...d coupling a worn shaft or auger placed on its vertical axis within the freezing cylinder The gear motor is made of a single phase electric motor with a permanent capacitor This motor is directly fitt...

Страница 14: ...40 psig Suction pressure 1 bar 14 psig REFRIGERANT CHARGE R 134 A 370 gr NOTE Beforechargingtherefrigerantsystem always check the type of refrigerant and quantity as specified on the individual ice ma...

Страница 15: ...MANUAL RESET see NOTE The condenser temperature sensor probe located within the condenser fins detects the condenser temperature variations and signals them by supplying current at low voltage to the...

Страница 16: ...e towards a rectangular opening located in the bottom of the storage bin Elapsed the dispensing time 5 10 or 15 seconds according to the setting or after removing the glass carafe the infrared resume...

Страница 17: ...owing instructions Switch OFF the machine Push and hold the PC Board push button Switch ON the machine keepiung pushed the PC Board push button till all LEDs are ON Release the push button ALL STEADY...

Страница 18: ...earings permanently lubricated The gear case contains a train of three spur gears the first one of which is in fiber to limit the noise level All the three gears are encased in case bearings and are c...

Страница 19: ...ing the proper membrane button b Place a glass or a carafe in front of the two Optical Dispensing Devices c The dispensing drive motor and or the water solenoid valve starts Ice and or water is discha...

Страница 20: ...ps Check for correct operation of drive after a while motor magnetic sensor Check for correct magnetic capacity of magnetic cylinder Compressor cycles intermittently Low voltage Check circuit for over...

Страница 21: ...st float valve setting screw Excessive noise or chattering Mineral or scale deposit on auger Remove and manually polish auger and inner freezer walls and inner walls of freezer barrel using emery pape...

Страница 22: ...p of a bit of ice machine cleaner plain 7 With the ice machine and fan motor OFF clean condenser using vacuum cleaner whiskbroom or non metallic brush taking care to do not damage the condenser temper...

Страница 23: ...ored It may also loose fluidity creating some resistance in being elevated and extruded this situation can be heard by the creaking noise made by the ice If this should occur it is recommended that yo...

Страница 24: ...n 11 Remove nut holding bin to chassis 12 Pull bin out of machine 13 Remove screws holding air deflector to chassis and pull deflector out of the unit 14 Remove screws holding reservoir to bulkhead pa...

Страница 25: ...ace large washers over coupling and small washer under bottom of bearing Insert bolt through large washers coupling and bearing Run one nut into bearing to center the bolt Add small washer and nuit Ti...

Страница 26: ...e thrust bearing and place it on top of the roller bearing The inner race of the roller bearing must project through the center of the flat thrust bearing 9 Install the flat washer provided with the n...

Страница 27: ...ring and bottom seal Rotating Half 1 Remove old rotating half from the auger Clean the mounting area 2 Place a bead of food grade sealant onto the shoulder of the auger where the rotating half of the...

Отзывы: