EMF 2306 Series Flake ICE Maker - Modular
I
S
O
9 0
0
1
C
E
R
T
I
F
I
E
D
fi
We reserve the right to make changes in design and construction at any time
without obligation.
2003© ICE-O-Matic Rev Code: 2007A-07/03-SS
ICE-O-Matic 11100 E. 45th Avenue, Denver, CO 80239
Tel. 303 371-3737 Fax. 303 371-6296 www.iceomatic.com
®
Air Out -
Both Sides
of ICE Maker
Air in -
Back of
of ICE Maker
Dimensions and Air Flow
Air Out -
Both Sides
of ICE Maker
24"
(610 mm)
76"
(1930 mm)
26"
(660 mm)
48"
(1219 mm)
31"
(787 mm)
EMF 2306
Conds.
Air Temp.
Water Temp. °F (°C)
Unit
°F (°C)
80°(27°)
70°(21°)
50°(10°)
90° (32°)
1681 (764)
1808 (822)
1986 (903)
90° (32°)
1730 (786)
1860 (845)
2066 (939)
80° (27°)
1791 (814)
1926 (875)
2119 (963)
80° (27°)
1878 (854)
2019 (918)
2221 (1010)
70° (21°)
1904 (865)
2047 (930)
2252 (1024)
70° (21°)
2009 (913)
2160 (982)
2376 (1080)
90° (32°)
2068 (940)
2224 (1011)
2384 (1084)
90° (32°)
1968 (894)
2116 (962)
2254 (1024)
80° (27°)
2117 (962)
2276 (1035) 2504 (1138)
80° (27°)
1992 (906)
2142 (974)
2357 (1071)
70° (21°) 2218 (1008) 2385 (1084)
2624 (1193)
70° (21°)
2080 (945)
2236 (1016)
2460 (1118)
90° (32°)
1700 (773)
1828 (831)
2047 (931)
80° (27°)
1870 (850)
2010 (914) 2212 (1005)
70° (21°)
2009 (913)
2160 (982)
2376 (1080)
50° (10°)
2424 (1102)
30° (-1°)
2472 (1124)
0° (-18°)
2521 (1146
)
All specifications and performance data are subject
to normal manufacturing variances.
Air
Cooled
Water
Cooled
Remote
Cooled
OPERATING LIMITS
Ambient Temp. Range
Air & Water
50° - 104°F (10° - 40°C) 60Hz
50° - 110°F (10° - 43°C) 50Hz
Remote
-20° - 120°F (-29° - 49°C) 60Hz
-20° - 110°F (-29° - 43°C) 50 Hz
Water Temp. Range
40° - 80°F (4.5° - 27°C)
Water Pressure Ice Maker
Min. 20 psi (1.4 bar)
Water in
Max. 60 psi (6.9 bar)
Condenser Inlet Water
Min. 20 psi (1.4 bar)
(Water cooled only)
Max. 60 psi (6.9 bar)
EMF2306AS
Air
2252 (1024)
1808 (822)
12.0 (45)
n/a
3.0
18978
208-230/60/1
3
14.9
15
370 (168)
EMF2306WS
Water
2624 (1193)
2224 (1011)
12.0 (45)
182.8 (692)
2.2
21600
208-230/60/1
3
12.8
15
370 (168)
EMF2306RS
Remote
2376 (1080)
1828 (831)
12.0 (45)
n/a
3.1
19194
208-230/60/1
3
15.5
15
370 (168)
ERC -2062
Remote Condenser for 1 model EMF 2306RS (208-230/50-60/1 voltage)
125 (57)
RT-325-404
25 ft. (7.6m) Precharged Tubing Kit for R-404A models
13 (6)
RT-340-404
40 ft. (12m) Precharged Tubing Kit for R-404A models
18 (8)
RT-345-404
45 ft. (13.7m) Precharged Tubing Kit for R-404A models
19 (9)
RT-360-404
60 ft. (18.2m) Precharged Tubing Kit for R-404A models
26 (12)
See Bin specification sheet for information on ICE storage bins
Please note: air-cooled units require 6” (152 mm) clearance for air intake and exhaust.
Water Used-Gals. (Lits.)
Kilowatts
ICEProduction
ICE Production
per 100 lbs. of Ice
Used per
per 24 hrs. at
per 24 hrs. at
90° Air/70° Water
100 lbs. of ICES
Min.
Max.
Shipping
Model
Cond.
70° Air/50° Water
90° Air/70° Water
90° Air
Voltage
No. of
Circuit
Fuse
Weight
No.
Unit
lbs. (Kgs.)
lbs. (Kgs.)
70° Water
Btuh
Characteristics
Wires
Amp.
Size
lbs. (Kgs.)
ICE Prod.
Cond.
Use
Use
60 Hz
ORDERING AND SPECIFICATION INFORMATION
ICE PRODUCTION CHART POUNDS
(KILOGRAMS) PER 24 HOURS
20.95"
(532mm)
TYP.
0.75" (19mm) TYP.
0.75" (19mm) TYP.
23.50"
(597mm)
0.75"
(19mm)
TYP.
9.00"
(229mm)
Hole for Strap
Mounting to Bin
ICE Maker - Water In
1/4" (6mm) Male Flare
ICE Machine - Water Out
9/16" (14mm) ID Plastic Tubing
0.50"
(13mm)
TYP.
9.00"
(229mm)
19.45"
(494mm)
TYP.
7/8" (22mm) DIA Hole
for Electrical Connections
to Control Box
7/8" (22mm) DIA Hole
for Electrical Connections
to Control Box for Remote
Condenser Fan Leads
Rear View
(Air Cooled)
48.00" (1219mm)
4.00" (102mm) TYP.
Minimum Wall
Clearance
ICE Dispense Area "To Bin"
in Bottom of Machine
- 5.50" (140mm)
11.41"
(290mm)
5.50"
(140mm)
TYP.
6.00"
(152mm)
Minimum Wall
Clearance
for Utility
Connections
Top View
26.00"
(660mm)
23.64"
(600mm)
Air Flow "Out"
R.H. Side View
20.95"
(532mm)
TYP.
0.75" (19mm) TYP.
0.75" (19mm) TYP.
23.50"
(597mm)
0.75"
(19mm)
TYP.
9.00"
(229mm)
Hole for Strap
Mounting to Bin
ICE Maker - Water In
1/4" (6mm) Male Flare
ICE Machine - Water Out
9/16" (14mm) ID Plastic Tubing
0.50"
(13mm)
TYP.
9.00"
(229mm)
19.45"
(494mm)
TYP.
7/8" (22mm) DIA Hole
for Electrical Connections
to Control Box
7/8" (22mm) DIA Hole
for Electrical Connections
to Control Box for Remote
Condenser Fan Leads
Rear View
(Air Cooled)