INSTALLATION GUIDELINES

3

All  drain  lines  must  be  installed  per  local  codes.

The purge drain should be a minimum of 3/4 inch

O.D. tubing. The condenser drain on water cooled

units should be 1/2 inch O.D. minimum. The drain

line fittings on Ice-O-Matic bins are 3/4 FPT. The

bin  drain should  be a minimum  of 3/4 inch O.D.

Cold  water  drains  should  be  insulated  to  prevent

condensation from forming.

Condensate Drain Installation

A condensate drain connection is available in the 

base of 22” and 30” ice makers. It may be 

necessary to use this connection if operating in 

high humidity.

1. Silicone around the outside of a 1/2” – 9/

16” OD flexible or rigid tube.

2. Insert the tube approximately 1” between 

the condensate drain hole and ice maker 

frame located on the back of the ice maker, 

below the primary purge water connection. 

3.

Tip: 

If the tubing is a challenge to insert, 

the screws holding the metal frame to the 

plastic base can be loosened. Re-tighten 

the screws once the tubing is fully inserted.

4. Run the tubing to drain, ensuring it is 

supported to prevent kinks or the drain line 

coming loose.

Silicone around the outer edge of the connection as

needed to ensure a proper seal.

Clearance Requirements

Self-contained air cooled ice machines should have

a minimum of 6 inches (15cm) of clearance at the

rear,  top,  and  sides  for  proper  air  circulation  and

adequate space for serviceability. 

Self-contained air-cooled ice machines exhaust air

out of the top and right side of the unit. By use of

SMART  HARNESS™  technology,  there  are  two

alternative  air  exhaust  options.  Option  A  (top

exhaust  bias):  minimum  of  6  inches  (15cm)  of

clearance at the rear and top of the ice machine for

proper function at maximum operating conditions.

Option B (side exhaust bias): minimum of 6 inches

(15cm) of clearance at the rear and right side of the

ice machine with a minimum of 3 inches (7.5cm)

of  clearance  at  the  top  for  proper  function  at

maximum operating conditions.

Appropriate  space  should  be  allowed  for  proper

serviceability of the machine. Excess time to gain

access  for  serviceability  is  not  covered  under

warranty. 

Stacking

Ice-O-Matic does not endorse stacking ice 

machines.

Dispenser Application

A thermostatic bin control kit should be installed if

the  CIM  Cube  ice  machine  is  placed  on  a

dispenser. A bin top may or may not be required

and should be secured to the dispenser.

Содержание ELEVATION Series

Страница 1: ...Ice O Matic 11100 East 45th Avenue Denver Colorado 80239 1 800 423 3367 9081484 01 REV R 4 2021 ELEVATION SERIES CUBE ICE MAKER CIM 300 lb through 2000 lb Cubers Installation Guide and Owner s Manual ...

Страница 2: ...vides this manual as an aid to the service technician in installation and maintenance of the CIM Series cube ice machines Do not attempt to perform installation start up or maintenance unless you have read and fully understand this manual Ice O Matic ice makers and dispensers are not approved for outdoor installation Air and water cooled ice machines are hermetically sealed and contain fluorinated...

Страница 3: ...xceeds 80 psi 5 5 bar a water pressure regulator must be installed All water supply lines must be installed per local codes Use 3 8 inch O D minimum on air cooled machines On water cooled machines 3 8 inch O D minimum tubing must be run to the condenser The water supply for the machine can T off from the condenser line using 3 8 inch O D minimum tubing Make 2 coils of extra tubing so that the mach...

Страница 4: ...rain line coming loose Silicone around the outer edge of the connection as needed to ensure a proper seal Clearance Requirements Self contained air cooled ice machines should have a minimum of 6 inches 15cm of clearance at the rear top and sides for proper air circulation and adequate space for serviceability Self contained air cooled ice machines exhaust air out of the top and right side of the u...

Страница 5: ... inch in all directions Check the water in the Water Sump for proper level Check the ice bridge for proper thickness Check the Water Regulating Valve adjustment if water cooled Secure the machine on top of the bin or dispenser Attach the ice machine to the bin with the mounting straps provided with the bin or dispenser Insure that the back of the ice machine is flush with the back of the bin Prope...

Страница 6: ...40 or 75 foot length to connect the ice machine to the remote condenser Select the best available location protecting the remote condenser from extremes of dirt dust and sun Meet all applicable building codes The services of a licensed electrician may be required Roof Attachment Install and attach the remote condenser to the roof of the building using the methods and practices of construction that...

Страница 7: ... makers incorporate the Mixing Valve in the condenser This configuration allows up to a 100 foot calculated remote line set run Reference the diagram on the next page to calculate the maximum 100 ft line set run Maximum actual line set run is limited to 100 ft The 75 foot line set will require 28 ounces of additional refrigerant Verify the CIM machine is compatible with the remote condenser For mo...

Страница 8: ...s Formula for maximum equivalent run RISE x 1 7 DROP x 6 6 HORIZONTAL RUN EQUIVALENT RUN NOT TO EXCEED 100 CALCULATED FEET Rise 35 ft x 1 7 40 ft 99 5 equivalent feet line run Drop 10 ft x 6 6 34 ft 100 equivalent feet line run 40 ft horizontal 35 ft rise 34 ft horizontal 10 ft drop ...

Страница 9: ... Hole for electrical connections 7 8 D Electrical junction box 7 8 CIM 2 W R Water Remote Cooled A Ice maker potable water in 3 8 FPT B Ice maker water out 3 4 FPT C Hole for electrical connections 7 8 D Electrical junction box 7 8 remote E Condenser water in 3 8 FPT water only Discharge line 1 2 male quick connect coupling for pre charged line set remote only F Condenser water out 1 2 FPT water o...

Страница 10: ... Hole for electrical connections 7 8 D Electrical junction box 7 8 CIM 3 W R Water Remote Cooled A Ice maker potable water in 3 8 FPT B Ice maker water out 3 4 FPT C Hole for electrical connections 7 8 D Electrical junction box 7 8 remote E Condenser water in 3 8 FPT water only Discharge line 1 2 male quick connect coupling for pre charged line set remote only F Condenser water out 1 2 FPT water o...

Страница 11: ...B Ice maker water out 3 4 FPT C Hole for electrical connections 7 8 D Electrical junction box 7 8 A Ice maker potable water in 3 8 FPT B Ice maker water out 3 4 FPT C Hole for electrical connections 7 8 D Electrical junction box 7 8 remote E Condenser water out 3 4 FPT water only Discharge line 1 2 male quick connect coupling for pre charged line set remote only F Condenser water in 3 8 FPT water ...

Страница 12: ...lusion of Anti Slush the unit will continue in freeze mode until the Low Water Float is satisfied closes indicating the formation of a full slab of Ice on the Evaporator and will start the harvest Cycle Harvest Cycle The Fan Motor shuts down as the Hot Gas Valve Purge Valve and Water Inlet Valve are energized The Water Inlet Valve will stay energized for additional time after the Purge Valve close...

Страница 13: ... above across the middle of the ice slab on the second batch produced The ice thickness can be changed on the Float Housing by turning the adjustment arm clockwise to decrease the bridge thickness and counter clockwise to increase the bridge thickness You will hear a click with each adjustment It is recommended adjustments be made one or two clicks at a time When a more substantial adjustment is n...

Страница 14: ...ss and adjustment procedure 3 Check water level in Sump See page 11 for proper water level and adjustment procedure 4 Clean the condenser air cooled machines to ensure unobstructed air flow 5 Check for leaks of any kind water refrigerant oil etc 6 Check the bin control switch if applicable for proper adjustment 7 Check the Water Regulating Valve water cooled machine for proper adjustment by measur...

Страница 15: ...ent diluted per manufacturer s instructions In addition for CIM models revision 4 and higher KAY 5 Sanitizer may also be used Please refer to www iceomatic com for approved chemical formulations and proper pH balance CAUTION Do not mix cleaner descaler and sanitizer together Eye protection is recommended when handling descaler or sanitizer Wear protective rubber gloves when handling descaler or sa...

Страница 16: ...ter spillway water distributor upper evaporator cover lower evaporator curtain and all splash surfaces Verify that all residue and residual minerals have been removed 16 If a full clean of water components is required this can be done by referring to the service manual for water system component breakdown This is recommended to be done by a qualified service agent 17 Re assemble all ice machine wa...

Страница 17: ...r machine looking like new 1 Clean the stainless steel and aluminum thoroughly once a week Clean frequently to avoid build up of hard stubborn stains Hard water stains left to sit can weaken the metals corrosion resistance and lead to rust or corrosion Use a nonabrasive cloth or sponge working with not across the grain 2 Do not use abrasive tools to clean the metal surface Do not use steel wool ab...

Страница 18: ...he frame let the back of sump fall downward 3 Similar to step 1 lift the front of the sump and push backward to allow the retaining features on the sump to clear the frame Push down towards the back until the sump is free from the frame Turn the sump sideways and remove it through the ice drop zone 4 To re install reverse steps 1 through 3 and tuck the water pump tube into the sump after the sump ...

Страница 19: ... evaporator s If ice is being made initiate harvest by pressing the Power Button for approximately 3 seconds The unit will shut off automatically following the harvest 3 Disconnect the tubing between the water pump discharge and water distribution tube and drain any water 4 On water cooled machines hold the water regulating valve open by prying upward on the water valve spring with a screwdriver w...

Страница 20: ...ing the plastic lampholder body and pulling away from the bulb Do not grip the lampholder by the connecting wires under any cir cumstances as this is a high voltage hazard The 4 pins on the pin end of the bulb will be exposed after disconnecting the lampholder 4 Push the bulb through the flat end of the end cap until approximately one inch of the bulb has moved through the pin end of the end cap 5...

Страница 21: ...bulb by inserting the flat end into the appropriate end cap 2 Reconnect the lampholder to the pin end of the bulb 3 Replace any access panels removed from the ice machine 4 Reconnect the power supply to the ice machine 5 Dispose of any old bulbs in accordance with all regulations pertaining to hazardous waste dis posal these bulbs contain small traces of mercury Visit lamprecycle org for informati...

Отзывы: