UWI-IQ manual (rev. 5.07.2019) 

Page 4/12   

 

 
 
 
 
 
 
OUTPUT terminal line

 

 

1    Loop + 

    

 optional output for control panel loop 

 

2     Loop - 

    

 optional output for control panel loop 

 

ALARM / NO   

 relay contact

 

4    ALARM / NC    

 relay contact

 

5    ALARM / COM 

 relay contact

 

FAULT/ NO 

 

 relay contact

 

7    FAULT / NC    

 relay contact

 

8    FAULT / COM  

 relay contact

 

 
 

   

 

Installation

 

 
1.  Configure wireless communication system with control panel  or peer 

to  peer  loop  (UWI-IQ  to  UWI-IQ  link)  before  units  placing  (see 
Appendix 2 or 3 for details)

 

2.  Connect the power supply (9-12V DC) to the terminals POWER

 

3.  Do  it  for both  UWI-IQ  which  should  be  configured  in  wireless  link. 

In case of  configuration UWI-IQ into uCU-IQ system  connect  also 
batteries  to  all wireless detectors in the system. During the start up 
time, the detector and UWI-IQ will give 2 short yellow blink every 4. 
sec.  in  30  sec.  (Do  not  forgot  to  Delete  previously  UWI-IQ 
configuration if any )

 

4.  Follow  the  instruction  from  the  manual    for  RF  monitor  - 

configuration    software  and  configure    wireless  system  or  wireless 
link (UWI-IQ to UWI-IQ -  peer to peer). (Wireless link is possible to 
configure the same way as  peer to peer CHOR-IQ detector loop.) 

 

5.  Select  the  UWI-IQ  for  user  configuration  by  RF  -monitor,  open  the 

UWI-IQ configuration page and set the required  UWI-IQ parameters  
like  input  delay,  output  delay,  local  relays  response,  response  to  Q 
message,  Hush  enable/disable.  Choose  the  parameters  in  accordance 
to  your  intended  UWI-IQ  application.  Set/check  the  configurable 
parameters of all UWI-IQ in installation /system.

 

6.  Choose the best place to fix the UWI-IQ unit with regards to an easy 

connection with the source of the input signal and/or  the  receiver of 
relay / Loop output signals  and power supply source. Find an optimal 
position especially with regards to the antenna. The antennas has to be 
oriented  so  that  the  same  polarisation  of  all  wireless  components  in 
system is secured.  The UWI-IQ unit  is possible to fix to a wall uCU-
IQ  alike.  UWI-IQ  is  intended  to  be  installed  into  an  instrument 
distribution  box.  Install  the  UWI-IQ  unit at  least 0.5m  from  fuse  box 
or  other  electrical  appliances.  Be  aware  that  EM  disturbances    can 
harm the universal interface

 

7.  Connect power supply wires  and the input(s), outputs on the UWI-IQ 

terminal board according to the intended UWI-IQ application. Fix the 

UWI-IQ  electronics  into  the  plastic  box  and  install  the  top  panel. 
(Remove  the  top  cover  of  the  UWI-IQ  carefully.  Put  a  flat 
screwdriver to the  left side of cover  groove and slightly lever to  left 
side and remove the top cover. Place the UWI-IQ  in vertical position 
into  instrument distribution box.  Use  2  screws  to  connect both  sides 
of the UWI-IQ to the box. Put the top cover of UWI-IQ backpanel.)  

 

8.  If  external  antenna  is  used,  check  carefully  the  antenna  connection 

(correct  coax  connection  of  the  pigtail  on  RM  module  and  
connection of the antenna to the  pigtail by SMA connector.)

 

9.  Check  the  Test  broadcasting  in  the  system.  Test  can  be  stopped  by 

press  of  any  UWI-IQ  or  detector    test  button  or  from  the  control 
panel.  The  test  mode  will  stops  automatically  in  about  3  minutes.

Содержание UWI-IQ

Страница 1: ...UWI IQ manual rev 5 07 2019 Page 1 12...

Страница 2: ...UWI IQ manual rev 5 07 2019 Page 2 12 UWI IQ Universal wireless interface in the band 868 MHz Universal wireless link UWI IQ to UWI IQ D R A F T...

Страница 3: ...not sent immediately but after a pre alarm time The alarm fault is tested repeatedly with period about 4 s and only after the specified number of positive tests is reached the corresponded message is...

Страница 4: ...Set check the configurable parameters of all UWI IQ in installation system 6 Choose the best place to fix the UWI IQ unit with regards to an easy connection with the source of the input signal and or...

Страница 5: ...ble flashes each delay step since the message has been received When the button is pressed during the running output delay or RESET message or possibly Q message if enabled is received no change of ou...

Страница 6: ...is indicated only if all samples in queue are tested as active If any sample in this pre alarm period is tested as normal the number of tested samples in queue is reset Default set is 2 samples The op...

Страница 7: ...pressed shortly or T message received Press the pushbutton shortly to TEST stop the detector gets into NORMAL and R message will be sent The TEST will be stopped after receiving of r message If no but...

Страница 8: ...The UWI IQ is trying to estimate the user intention and if the UWI IQ is in other status than normal a simple short press and release of the detector button can be the first easy solution of the most...

Страница 9: ...Test Leds is lighting test message T is sent by SPI and forwarded by the radio module The radio communication range can be tested this way By long press of the TEST RESET push button till lit of both...

Страница 10: ...output in fire condition increased current of the loop to alarm value until receiving of stop alarm s reset r quit q _ if enabled or hush h _if enabled message or quit by a short TEST RESET button pre...

Страница 11: ...ion byte CFG with following meanings of single bits CFG Configuration byte structure FIN ALARM INPUT CONFIGURATION 0 NO input active if closed 1 NC input active when open EIN FAULT INPUT CONFIGURATION...

Страница 12: ...OL is not necessary more The switch at the position J3 on the terminal board allows to choose between IFC and IMC control panels and the loop current is switched to a correspondent standby level autom...

Отзывы: