background image

 

switch..it   Installation Guide 

 

 

 

 

 

 

 

 

 

 

Subject to change 

date: 09.12.2016 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 1 

IBT Interfaces, Schwalbenstr. 6, 63322 Rödermark 
Tel.      +49 (0) 6074 / 69 64 16-0 
Fax.     +49 (0) 6074 / 69 64 16-1 
E-Mail: 

[email protected]

 

Web:  

www.ibt-interfaces.de

 

 

 
 
 
 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
 

switch...it 

Installation Guide 

V1.11 

 

 

Содержание SWITCH..IT

Страница 1: ... Subject to change date 09 12 2016 Page 1 IBT Interfaces Schwalbenstr 6 63322 Rödermark Tel 49 0 6074 69 64 16 0 Fax 49 0 6074 69 64 16 1 E Mail sales ibt interfaces de Web www ibt interfaces de switch it Installation Guide V1 11 ...

Страница 2: ...P IP Protokolle 8 switch it Systemkabel 8 Serial RS 422 cable for IBT panel matrixes Snell Miranda Nevion Multicon 8 Serial RS 422 cable for switcher Kahuna MVS 3000 65xx XtendD DD30 KAYAK 9 Serial RS 422 cable for switcher Sony MVS 6000 8000 Mischer 9 Serial RS 422 cable for Stagetec Nexus 10 Serial RS 422 cable for first IBT UMD of daisy chain bus 10 Serial RS 422 cable for IBT UMD daisy chain b...

Страница 3: ...the product safety requirements of the country in which they are used For this device a power cord with a protective conductor is required The power cord must be rated for a nominal voltage of 240V AC To ensure safety and permanent fire protection all fuses may be replaced only by identical fuses with identical electrical data for the corresponding fuse location Mechanical Installation instruction...

Страница 4: ...ges appear and press the wheel knob once again to confirm and exit the edit mode If you like to discard the changes turn the wheel knob to the left until discard changes will appear and confirm by pressing wheel knob Set up Client Netmask Turn the LCD wheel knob on the front panel to the right until you reach the menu entry Client Netmask Follow the instruction of Set up Client IP Address point 1 ...

Страница 5: ... 69 64 16 0 Fax 49 0 6074 69 64 16 1 E Mail sales ibt interfaces de Web www ibt interfaces de Frame connections 1 Power connector with fuses 2 x 1 6AT 3 RS 232 upper connector debug port 4 RS 422 serial communication ports optional 5 GPIO Interface outputs optional 2 Ethernet port lower connector 6 GPIO Interface inputs optional ...

Страница 6: ... B8 female Pin Nr Signal 1 n c 2 n c 3 n c 4 Rx 5 Tx 6 n c 7 n c 8 GND For future use LAN Interface RJ 45 B8 female Pin Nr Signal 1 Tx 2 Tx 3 Rx 4 n c 5 n c 6 Rx 7 n c 8 n c Frame 1 0 serial number XX 00242 selling date before 06 05 2015 Forced to 10Mbit half duplex Intelligent switches need to be set either to 10 Mbit half duplex to avoid duplex mismatch errors Frame 2 0 serial number XX 00242 se...

Страница 7: ...out 4 4 Opto In 4 5 out 5 5 Opto In 5 6 out 6 6 Opto In 6 7 out 7 7 Opto In 7 8 out 8 8 Opto In 8 9 out 9 9 Opto In 9 10 out 10 10 Opto In 10 11 out 11 11 Opto In 11 12 out 12 12 Opto In 12 13 out 13 13 Opto In 13 14 out 14 14 Opto In 14 15 out 15 15 Opto In 15 16 out 16 16 Opto In 16 17 n c 17 n c 18 n c 18 n c 19 n c 19 n c 20 n c 20 n c 21 n c 21 n c 22 Volt 22 Volt 23 Volt 23 Volt 24 Comm cont...

Страница 8: ...2 Probel SWP 08 TSL 5 0 VTS IMD Monitore Kahuna 360 serial Tally Sony ROT16 LAWO Remote MNOPL Nevion MRP RT Soft Remote Desk Grass Valley GVS Tally Miranda Kaleido Remote switch it Systemkabel Serial RS 422 cable for IBT panel matrixes Snell Miranda Nevion Multicon SER 2 to switch it Panel RS 422 SER 2 to Nevion matrix with Multicon Probel Protocol SER 2 to Miranda Nvision SER 2 to Probel Sirius m...

Страница 9: ...witcher Kahuna MVS 3000 65xx XtendD DD30 KAYAK SER 2 to Switcher DD30 MPK ACOS Protokoll SER 2 to Switcher MVS 3000 MVS 65xx SER 2 to Switcher XtendD MPK ACOS Protokoll SER 2 to Switcher KAYAK MPK ACOS Protokoll SER 2 to Switcher Kahuna D Sub S9 male to D Sub S9 male 1 2 Drawing Serial RS 422 cable for switcher Sony MVS 6000 8000 Mischer SER 2 to System Control Unit MKS 8010B Editor Panel Port D S...

Страница 10: ...Tel 49 0 6074 69 64 16 0 Fax 49 0 6074 69 64 16 1 E Mail sales ibt interfaces de Web www ibt interfaces de Serial RS 422 cable for Stagetec Nexus SER 2 to IBT UMD D Sub S9 male to PS 2 male 1 2 Drawing Serial RS 422 cable for first IBT UMD of daisy chain bus SER 2 to IBT UMD D Sub S9 male to D Sub S9 male 1 2 Drawing ...

Страница 11: ...074 69 64 16 0 Fax 49 0 6074 69 64 16 1 E Mail sales ibt interfaces de Web www ibt interfaces de Serial RS 422 cable for IBT UMD daisy chain bus IBT UMD to IBT UMD D Sub S9 male to D Sub S9 male 1 2 Drawing Serial RS 422 cable for Multiviewer Miranda KX Serie SER 2 to Multiviewer KX 16 D Sub S9 male to RJ 45 S8 male 1 2 Drawing ...

Страница 12: ...Fax 49 0 6074 69 64 16 1 E Mail sales ibt interfaces de Web www ibt interfaces de Serial RS 422 cable for Multiviewer Evertz MVW VIP A8 Duo SER 2 to Multiviewer VIP A8 DUO D Sub S9 male to HD D Sub S15 male 1 2 Drawing Serial RS 422 cablel for Multiviewer Evertz Quad VIP 4 SER 2 to Quadsplit VIP 4 D Sub S9 male to Screw connection 1 2 Drawing ...

Страница 13: ...4 69 64 16 1 E Mail sales ibt interfaces de Web www ibt interfaces de GPIO input output connections GPIO card IN OUT to GPI IN OUT HD D Sub S26 male on cable to GPI Outputs HD D Sub B26 female on cable to GPI Inputs The drawing shows a manufactured cable GPIO OUT Male on cable and female on unit card GPIO IN Female on cable and male on unit card Drawing ...

Страница 14: ...tallation guide 4 Check that the Unit IP Address in the GUI Menu System Set up page is entered as expected without leading zeros Example Right 192 44 32 10 Wrong 192 044 032 010 Webpanel can not connect 1 Check that the GUI IP Address in the GUI Menu System Setup page is entered as expected without leading zeros Expected is here the IP Address of the configuration PC itself Example Right 192 44 32...

Страница 15: ...16 Page 15 IBT Interfaces Schwalbenstr 6 63322 Rödermark Tel 49 0 6074 69 64 16 0 Fax 49 0 6074 69 64 16 1 E Mail sales ibt interfaces de Web www ibt interfaces de Nevion MRP Protocol Firmware must be grater or equal version 2 6 2 TCP IP MRP Protokoll Port 4381 ...

Страница 16: ...date after 06 05 2015 Power supply AC 100 240V max 1A Wight approx 7 0Kg Changeindex Version Date Done by Change v1 00 18 05 2010 NK Neu erstellt v1 01 31 05 2010 NK Korrektur Multiviewerkabel Seite 11 v1 02 04 06 2010 NK Textkorrekturen v1 03 01 02 2011 NK Spezifikationen hinzugefügt und Korrektur GPI Stromaufnahme v1 04 15 03 2012 NK Miranda Nvision Kabel v1 05 25 09 2012 NK Sonderkabel für Sony...

Страница 17: ...nstallation Guide Subject to change date 09 12 2016 Page 17 IBT Interfaces Schwalbenstr 6 63322 Rödermark Tel 49 0 6074 69 64 16 0 Fax 49 0 6074 69 64 16 1 E Mail sales ibt interfaces de Web www ibt interfaces de ...