Industrial Bolting Technologies IBT-115 Single-Port Power Pack
4
IBT-115 Single-Port Power Pack:
•
This hydraulic electric pump has a maximum operating pressure of 21,750 PSI/1500 Bar.
•
Pressures in excess of 21,750 PSI/1500 Bar can damage the pump.
•
Do not tamper with the internal high pressure relief valve.
•
Creating pressure beyond rated capacities can result in serious personal injury.
•
Before replenishing the hydraulic oil, retract the system to prevent overfilling the pump
reservoir.
•
Overfilling can cause personal injury due to excess reservoir pressure created
when the tensioners are retracted.
•
Shut off power before servicing equipment.
•
Ensure pump is properly grounded to avoid electric shock.
•
Do not modify this pump.
•
Any modification will result in a voided warranty and may result in personal
injury.
•
Fill the hydraulic fluid reservoir to the recommended level. Do not overfill.
•
Oil temperature exceeding 140 F can cause the pump to fail.
•
Keep the hydraulic pump clean.
•
Dirt in the oil can lead to pump failure.
•
Change oil and filter assembly annually.
Power Supply:
•
Disconnect the hydraulic power pack from the power supply when performing
maintenance or repairs.
•
If the power supply is damaged or the inner wiring is exposed in any way, replace
immediately.
•
If the power cord is damaged or wiring is exposed, replace or repair immediately.
•
Check the total amperage draw for the electrical circuit you will be using.
•
Low amperage can trip electric breakers and cause the power pack to heat
excessively.
•
If using an extension cord to power the hydraulic pump, make sure it is 12 gauge or
better.
Use a stable electric source. If power supply is unsteady, it may affect the performance and
damage the hydraulic power pack..