background image

22. IR Sensor einstellen

      Adjust IR sensor

For the first adjustment of the IR sensor 

it is necessary to set the Nozzle height 

to 0,50mm from the print bed.

The simplest method is to let the ma-

chine drive into the print bed with the 

„Home“ button and then turn it off qui-

ckly. (Only with cold Nozzle!)

When done, turn the machine back on 

and move up by „Move“ in 0.1mm steps 

until the calibration strip slides under the 

nozzle. Now your Nozzle is about 0.50 - 

0.60mm away from the bed and you can 

now adjust the IR sensor.

To do this, turn the adjusting screw to the right until the red LED lights up. Now your IR sensor is 

set to a height of approx. 0.50mm.

(One turn of the set screw corresponds to 0.5mm height!)

Now repeat homing and the nozzle should now be about 0.5mm from the bed.

If this is not the case, use the calibration strip by moving the nozzle up or down 0.1 mm with 

„Move“ until the strip fits exactly. Now set the IR sensor exactly so that the LED starts to glow in 

this position.

If you can not move the nozzle down far enough, turn the set screw to the left and re-homing.

Fine adjustment of the IR sensor:

After printing starts, you can go to the „Baby Stepping“ via the „More“ button. Use „UP“ and 

„Down“ to set the height in 0.025 increments during the first layer. If you press „Save“ these set-

tings will be saved for the next print!

www.inventbox.com

JOIN OUR Community !

www.inventbox.com/de/produkte/jg-aurora-upgrades/jg-titan-mkii-kit/support

Facebook Group: „JG Aurora A5 / A3S MKII Upgrades“

For what do I need the enclosed 100ohm resistor?

We designed the cooler for printing at temperatures up to 300c 

in combination with a Full Metal Heatbreak. If you do not need 

this and only print up to max. 260c, so you can solder the en-

closed resistor in front of the fan in order to reduce its volume.

Содержание JG Titan MKII

Страница 1: ... the Z axis limit switch and replace it with the 40cm 3 pin female female cable see Fig Führen Sie das Kabel durch die rechte Gehäuseöffnung siehe Abb Feed the cable through the right housing opening see picture Schließen Sie das Gehäuse und montie ren Sie den Z Rahmen Führen Sie das Kabel während der Montage wie abge bildet zur Oberseite Close the housing and mount the frame Guide the cable to th...

Страница 2: ...rough the notch on the heat sink and insert them up The cable of the temperature sensor must be inserted first www inventbox com 3 Nozzle Abstand einstellen Set Nozzle distance 4 Kühler montieren Mount radiator 2 Druckkopf demontieren Dismantle the printhead Demontieren Sie vorsichtig sämtliche Teile am Druckkopf und entfernen Sie alle Stecker bis nur noch Endschal ter Heizer und Temperaturfühler ...

Страница 3: ...embly details at www inventbox com Wichtige Infos zum Extruder Information about the extruder Die Spannmutter A muss korrekt in die Führung eingelegt sein Die Materialzu führung B muss bis ganz knapp an das Kugellager führen Die Schraube E ist extrem problematisch fest zu ziehen Sie müssen diese ganz langsam gegen den Uhrzeigersinn drehen bis Sie das 1ste von 2 klicken des überspringen Gewin des h...

Страница 4: ...TFE tube Make sure that the PTFE tube really goes all the way to the heat break Put the guide on and measure the distance Cut exactly the measured length so that the guide sits flush on the aluminum head Do not use pliers or scissors www inventbox com 6 PTFE Schlauch anpassen Adjust PTFE tube 5 Extruder vorbereiten Prepare extruder Lösen Sie die 3 schwarzen Kreuzschlitz Schrauben und die silberne ...

Страница 5: ...lers zuletzt eingelegt wird Setzen Sie danach den Extruder Deckel auf Lay all cables through the side cover Make sure that the cable of the tempera ture sensor is inserted last Then put the extruder lid on 9 Seitendeckel fixieren Mount side cover Schrauben Sie mit der M2x10mm Schraube den Seitendeckel am Kühlkör per fest Hierzu benötigen Sie evtl einen hochwertigen 1 5mm Inbus Schlüssel da billige...

Страница 6: ...ontieren Mount Extruder flush Please note the information under Extruder regarding the problematic Allen screw Demontieren Sie die Frontplatte des Druckkopfes und setzen Sie die beiden schwarzen ABS Distanzhülsen in die Bohrungen ein Disassemble the front panel of the printhead and insert the two black ABS spacers into the holes Schieben Sie dann den IR Sensor vor sichtig von oben nach unten auf T...

Страница 7: ... Sie den PTFE Schlauch auf die korrekte Länge Benutzen Sie keine Zange oder Schere Das Ende sollte bis knapp an das Kugellager des Extruders reichen Cut the PTFE tube to the correct length Do not use pliers or scissors The end should reach almost to the ball bearing of the extruder PTFE Schlauch evtl etwas anspit zen und in den Extruder schieben Es sollte zwischen Kugellager und PTFE Schlauch ca 1...

Страница 8: ... können Sie die Kabel nach unten schieben Pass the IR sensor cable through the cable channel and connect it to the output of the controller Then you can push the cables down Benutzen Sie ein Stück 1 78mm Fila ment um den alten Extruder in geöffne ter Stellung zu fixieren Schieben Sie es nicht zu weit hinein da es sonst die Zufuhr blockiert Use a piece of 1 78mm filament to fix the old extruder in ...

Страница 9: ... the next step it is important that you align the bed as well as possible parallel to the top of the housing Set all 4 cor ners to the same height Benutzen Sie eine Schieblehre oder etwas ähnliches um die X Achse auf beiden Seiten auf die gleiche Höhe zu schrauben Drehen Sie hierzu langsam an den Spindelkupplungen Use a caliper or something similar to screw the x axis to the same height on both si...

Страница 10: ...t 0 5mm Höhe Jetzt wiederholen Sie dass Homing und die Nozzle sollte nun ca 0 5mm Von der Oberseite ent fernt sein Sollte dies nicht der Fall sein benutzen Sie den kalibrierungsstreifen indem Sie die Nozzle mit Move 0 1mm so lange nach unten oder oben fahren bis der Streifen exakt passt Jetzt stellen Sie den IR Sensor genau so ein dass die LED exakt in dieser Position beginnt zu leuchten Sollten S...

Страница 11: ...case use the calibration strip by moving the nozzle up or down 0 1 mm with Move until the strip fits exactly Now set the IR sensor exactly so that the LED starts to glow in this position If you can not move the nozzle down far enough turn the set screw to the left and re homing Fine adjustment of the IR sensor After printing starts you can go to the Baby Stepping via the More button Use UP and Dow...