Thanks to large accessories and additional extensions, the REVI250 USB  monitoring system 
can  be  used  in  sewers  and  pipes  with  diameters  from  DN50  to  cca  DN150.  For  DN50  to 
DN150 use the push camera with the laminated cable rod attached on the push rod reel up 
to 80 m length, designed especially for home sewerages or water supplies. 

 

Power supply and connectors 

The system is powered by AC voltage from 110 to 240V 50 or 60 Hz or supplied by internal 
chargeable accumulator. An electric generator can be used if necessary. 
In this case, only a generator designed for the electronics and computers can be used. This 
type of generator has a converter on the output, which ensures supply with filtered voltage 
and  is  protected  against  overvoltage.  If  you  have  doubts  about  your  source,  contact  the 
customer  service  or  the  IBOS  a.s.  technician  who  will  assist  you  with  finding  a  suitable 
source. If you use an unsuitable source the system could be damaged.

 

Version AKU – LED function

 

Green LED 

- POWER

 

    off - the device is completely switched off

 

    on - the green switch is turned on or the power cable is connected

 

Yellow LED 

- CHARGING

 

    off - the power cable is not connected

 

    flashing - battery is charged

 

    on - the battery is fully charged and the power cable is still connected

 

Red LED 

– LOW BATTERY

 

    off -  from 100% to 20% of charge

 

    on – less than 20% of charge 
    flashing - less than 10% of charge 
 

Do  not  expose  the  batteries  to  the  temperature  below  0°C,  it  may  cause 
unrepairable dammage! If the batteries are discharged, charge them as soon 
as possible! If the batteries are stored for a longer time, regulary check their 
conditions  and  eventualy  recharge  them.  The  long  term  storage  of 
discharged batteries shortens their lifetime and may cause their dammage. 
  

 

Control unit connectors 

 
 

 
 

 

 

 

 
Without recording to USB storage 

It is not necesary to turn on the USB recorder (black button „on/off“) if the recorded images 
are not required. Only press the „Power“ button on the top panel. 
For the control of camera use another control element such as the potenciometr “LIGHT” for 
regulation of LED diods, red button “PROBE/R100” to turn on the sonde or REVI100 camery 
REVI100. 

Fuse F 3.15A 

AC supply 

connector 

Cable drum 

Содержание REVI250 USB

Страница 1: ... User s manual v1 4 07 2017 Manual for safe operation of the monitoring system and its maintenance to ensure trouble free operation All registered marks and trademarks mentioned in the guide are owned by the corresponding owners ...

Страница 2: ...nly if it is correctly maintained and operated Guide purpose This guide serves as a manual for commissioning using and maintaining the monitoring system produced by IBOS a s and includes also important safety instructions Read this guide before start working with this system Pay attention to articles on safety that protect your health and prevent hazards connected with operation of the whole syste...

Страница 3: ...g Different usage or usage beyond this scope is not considered the corresponding application Never use this inspection system for different purposes The system must not be used in piping with media subject to explosion For this purpose special equipment marked is specially produced and approved Type labels You can find type labels with the corresponding serial number on the individual components Y...

Страница 4: ...l sheets for maintenance and care regular checking of the personnel for conscious work as regards safety and hazards Personal safety The person responsible for operation maintenance and additional modifications of the equipment must be specialists or trained by a specialist The specialists must have adequate knowledge in inspection systems through special training and experience They are acquainte...

Страница 5: ...ipment beyond operations described in this manual can only be performed by a specialized trained person Larger maintenance or repairs can only be performed by the IBOS a s customer service or persons authorized by the IBOS a s Company Before cleaning maintenance and repair unplug apparatus from wall socket or power supply and follow the User s manual Danger of serious injuries caused by a touch of...

Страница 6: ... inspection system alternatively for inspections in waste water and pure water Even thorough cleaning of the system cannot guarantee adequate protection against contamination Use a special system for inspections in waste water and pure water When assembling components containing thread use the grease and the corresponding sealing elements for maximum tightness When tightening the threads do not us...

Страница 7: ...d connectors Axial camera head Camera head is connected to reel by special connector and can be equiped with Front Skids Conpatability of Control units and camera heads REVI100 push camera The camera has an image stabilization circuit integrated LED light and operates in diameters from 40 to 100mm Cable length is usually from 10 to 20m The light is provided by 4 LEDs It is possible to center the c...

Страница 8: ...page 7 Parts of the system Axial camera centering part assembly ...

Страница 9: ...en LED POWER off the device is completely switched off on the green switch is turned on or the power cable is connected Yellow LED CHARGING off the power cable is not connected flashing battery is charged on the battery is fully charged and the power cable is still connected Red LED LOW BATTERY off from 100 to 20 of charge on less than 20 of charge flashing less than 10 of charge Do not expose the...

Страница 10: ...s and REVI250 or REVI350 push rod reels Control panel REVI250 USB Monitoring The fibreglass cable pushes the camera head forward throught the pipes The exact lenght of the extended cable is shown on the monitor in meters During the monitoring of wider pipes and sewers use the front skids USB 2 0 Light control On Off power On Off Sonde or REVI100 On Off USB recorder The flashing of the LED indicate...

Страница 11: ...case of the recording video from monitoring to USB SD it is needed to have the USB SD recorder turned on by Camera DVR button Modes USB recorder firmware v2 1 Live video Back press to switch between the USB disc and interna SD card only when the both are present Stop if we press and hold 2 seconds to enter setup Play Pause switch to thumbnail recorded videos Forward Snapshot snapshot live video Re...

Страница 12: ... and the free space falls below 10 capacity of the media it will start to delete the oldest files Auto delete only deletes the files created by the recorder other files will remain intact Playback Back does nothing Stop stop stops recording and returns to display thumbnail images Play Pause pause Forward Snapshot saves a sreenshot Record pause in browsing viewing When playing the green LED lights ...

Страница 13: ...rd does nothing Copying of all files from the internal memory to a flash disk If any file is selected highlighted by the red line press consecutively the keys Back and Forward After dialog appears press the Play key to start the copying of all files The SD card must have a write rate of min Flash disk must be formatted to FAT32 USB recorder supports Flash in size max 2TB FAT32 limit For recording ...

Страница 14: ...page 13 USB recorder Menu structure ...

Страница 15: ...Ctrl F3 Set DATE Ctrl F4 Set TIME Ctrl F6 Set title line text Ctrl F7 Store Save the entire editor area text to the memory Pages 1 10 Ctrl F8 Store Save the text from start of actual line to cursor position to the memory Lines 1 100 Ctrl F9 Recall Paste the entire page from memory Ctrl F10 Recall Paste text from saved lines 1 100 to cursor position Alt F1 DATE on off Alt F2 TIME on off Alt F3 DIST...

Страница 16: ...ext two numbers 0 to 9 to complete the three digit number You do not need to hold the Alt key for the second and third digit number The fix text line will be loaded immediately whenever you entered a valid three digit number If you press a non digit key the process of recalling a fix text page is aborted Screen Configuration Screen configuration with title line at the top date time and distance at...

Страница 17: ...aintenance common wear or inevitable accidents lightning fire frost are exempt from the guarantee The warranty does not cover quickly worn out components such as the front glass shaft sealing rings light bulbs cables etc or damages that have no negative effect on usability of the equipment If you wish to claim a warranty contact IBOS a s Company our business representatives or the nearest customer...

Страница 18: ... control panel main switch junction boxes transformer DC source LCD display 4 The reel for the cable Disclaimer We declare that this product complies with the technical requirements that apply to it and the product follows the guidelines of the European Union and the Government of the Czech Republic List of technical regulations Czech Republic Goverment Regulation No 17 2003 Czech Republic Goverme...

Отзывы: