IBOS REVI250 USB Скачать руководство пользователя страница 16

 

 

page   

15

 

 

Advanced OSD functions 

For recalling fix text pages and lines silently (without writing a dialogue or edit window on screen) we 
added new keyboard commands in version 2,08 of the firmware. 

The range of memory locations of fix text pages is from 1 to 10. The memory number is always a two 
digit number to be entered in the range 01 to 10. To recall a page of fix text press and hold the [Alt] 
key and then press the first decimal digit number key [0] or [1]. Then enter the next number 1 to 9 
complete the two digit number. You do not need to hold the [Alt] key for the second digit number. 
The fix text page will be loaded immediately whenever you entered a valid two digit number. If you 
press a non digit key the process of recalling a fix text page is aborted. 

The range of memory locations of fix text lines is from 1 to 100. The memory number is always a two 
three number to be entered in the range 001 to 100. To recall a line of fix text press and hold the 
[Ctrl]  key  and  then  press  the  first  decimal  digit  number  key  [0]  or  [1].  Then  enter  the  next  two 
numbers 0 to 9 to complete the  three  digit number.  You do not  need to hold the  [Alt] key for the 
second and third digit number. The fix text line will be loaded immediately whenever you entered a 
valid three digit number. If you press a non digit key the process of recalling a fix text page is aborted. 

Screen Configuration 

 

 

 

 

 

 

 

 

 

Screen configuration with title line at the top, date, time and distance at bottom and the edit area between 

Shows the standard screen configuration with 2 status lines – one title line for user text on the upper 
edge of the screen and a line with the values date, time and distance at the bottom (blue background 
on  the  left).  The  user  edit  area  is  located  in  between  these  two  lines  (example  with  purple 
background on the right). The status lines can be toggled on and off individually by F2 key. It is also 
possible  to  switch  on/off  displaying  of  individual  fields:  date  (F3),  time  (F4)  and  distance  (F5).  The 
display of text in the edit area or the complete overlay can be switched on and off as well by F6. The 
overlay  hardware  allows  a  maximum  of  16  lines  each  with  a  maximum  of  30  characters.  In  the 
screenshots above you can see a resolution of 15 lines and 28 characters. 

 

User page name 

User defined text 

Date,Time,Distance 

Содержание REVI250 USB

Страница 1: ... User s manual v1 4 07 2017 Manual for safe operation of the monitoring system and its maintenance to ensure trouble free operation All registered marks and trademarks mentioned in the guide are owned by the corresponding owners ...

Страница 2: ...nly if it is correctly maintained and operated Guide purpose This guide serves as a manual for commissioning using and maintaining the monitoring system produced by IBOS a s and includes also important safety instructions Read this guide before start working with this system Pay attention to articles on safety that protect your health and prevent hazards connected with operation of the whole syste...

Страница 3: ...g Different usage or usage beyond this scope is not considered the corresponding application Never use this inspection system for different purposes The system must not be used in piping with media subject to explosion For this purpose special equipment marked is specially produced and approved Type labels You can find type labels with the corresponding serial number on the individual components Y...

Страница 4: ...l sheets for maintenance and care regular checking of the personnel for conscious work as regards safety and hazards Personal safety The person responsible for operation maintenance and additional modifications of the equipment must be specialists or trained by a specialist The specialists must have adequate knowledge in inspection systems through special training and experience They are acquainte...

Страница 5: ...ipment beyond operations described in this manual can only be performed by a specialized trained person Larger maintenance or repairs can only be performed by the IBOS a s customer service or persons authorized by the IBOS a s Company Before cleaning maintenance and repair unplug apparatus from wall socket or power supply and follow the User s manual Danger of serious injuries caused by a touch of...

Страница 6: ... inspection system alternatively for inspections in waste water and pure water Even thorough cleaning of the system cannot guarantee adequate protection against contamination Use a special system for inspections in waste water and pure water When assembling components containing thread use the grease and the corresponding sealing elements for maximum tightness When tightening the threads do not us...

Страница 7: ...d connectors Axial camera head Camera head is connected to reel by special connector and can be equiped with Front Skids Conpatability of Control units and camera heads REVI100 push camera The camera has an image stabilization circuit integrated LED light and operates in diameters from 40 to 100mm Cable length is usually from 10 to 20m The light is provided by 4 LEDs It is possible to center the c...

Страница 8: ...page 7 Parts of the system Axial camera centering part assembly ...

Страница 9: ...en LED POWER off the device is completely switched off on the green switch is turned on or the power cable is connected Yellow LED CHARGING off the power cable is not connected flashing battery is charged on the battery is fully charged and the power cable is still connected Red LED LOW BATTERY off from 100 to 20 of charge on less than 20 of charge flashing less than 10 of charge Do not expose the...

Страница 10: ...s and REVI250 or REVI350 push rod reels Control panel REVI250 USB Monitoring The fibreglass cable pushes the camera head forward throught the pipes The exact lenght of the extended cable is shown on the monitor in meters During the monitoring of wider pipes and sewers use the front skids USB 2 0 Light control On Off power On Off Sonde or REVI100 On Off USB recorder The flashing of the LED indicate...

Страница 11: ...case of the recording video from monitoring to USB SD it is needed to have the USB SD recorder turned on by Camera DVR button Modes USB recorder firmware v2 1 Live video Back press to switch between the USB disc and interna SD card only when the both are present Stop if we press and hold 2 seconds to enter setup Play Pause switch to thumbnail recorded videos Forward Snapshot snapshot live video Re...

Страница 12: ... and the free space falls below 10 capacity of the media it will start to delete the oldest files Auto delete only deletes the files created by the recorder other files will remain intact Playback Back does nothing Stop stop stops recording and returns to display thumbnail images Play Pause pause Forward Snapshot saves a sreenshot Record pause in browsing viewing When playing the green LED lights ...

Страница 13: ...rd does nothing Copying of all files from the internal memory to a flash disk If any file is selected highlighted by the red line press consecutively the keys Back and Forward After dialog appears press the Play key to start the copying of all files The SD card must have a write rate of min Flash disk must be formatted to FAT32 USB recorder supports Flash in size max 2TB FAT32 limit For recording ...

Страница 14: ...page 13 USB recorder Menu structure ...

Страница 15: ...Ctrl F3 Set DATE Ctrl F4 Set TIME Ctrl F6 Set title line text Ctrl F7 Store Save the entire editor area text to the memory Pages 1 10 Ctrl F8 Store Save the text from start of actual line to cursor position to the memory Lines 1 100 Ctrl F9 Recall Paste the entire page from memory Ctrl F10 Recall Paste text from saved lines 1 100 to cursor position Alt F1 DATE on off Alt F2 TIME on off Alt F3 DIST...

Страница 16: ...ext two numbers 0 to 9 to complete the three digit number You do not need to hold the Alt key for the second and third digit number The fix text line will be loaded immediately whenever you entered a valid three digit number If you press a non digit key the process of recalling a fix text page is aborted Screen Configuration Screen configuration with title line at the top date time and distance at...

Страница 17: ...aintenance common wear or inevitable accidents lightning fire frost are exempt from the guarantee The warranty does not cover quickly worn out components such as the front glass shaft sealing rings light bulbs cables etc or damages that have no negative effect on usability of the equipment If you wish to claim a warranty contact IBOS a s Company our business representatives or the nearest customer...

Страница 18: ... control panel main switch junction boxes transformer DC source LCD display 4 The reel for the cable Disclaimer We declare that this product complies with the technical requirements that apply to it and the product follows the guidelines of the European Union and the Government of the Czech Republic List of technical regulations Czech Republic Goverment Regulation No 17 2003 Czech Republic Goverme...

Отзывы: