13
PUMP INSTALLATION:
It should be remembered that all connections coming out of the
device and entering the device are tight because any leakage on the
installation: pipes, connections, basin faucet, cistern can cause
continuous activation of the device and subsequent combustion of the
motor. In addition, leaks may cause flooding of the device's engine or its
failure.
Despite the non-return valve installed in the pump, the user should
absolutely purchase and install an additional non-return valve on the
system, which will protect the device against possible switching on.
There must be no siphons along the discharge pipe and a minimum fall
of 1%.
The height of the shell exit should be about 175mm. The discharge
pipe should be rigid so that the output from the pump is not damaged. In
the case of a shower tray, the outflow should be at a height of 130mm
TECHNICAL DATA:
Capacity max: 300l / m
Max. distance of: 90m
Max. lifting height: 9 m
Power: 600W
Capacitor: 16
μ
F / 230V
Net weight: 8,5 kg