21
TROUBLESHOOTING
Warning:
Before any maintenance or repair activities, make sure that the power supply is cut off and cannot be
turned on by accident.
!
Overcurrent circuit breaker switched off
Start the breaker
Pump damaged
Loud system operation
I
ssue:
The pump fails to launch
Tripped installation fuse
Check the cause, replace the fuse
Possible cause:
Solution:
Replace the pump
Voltage too low
Check if the main voltage
is compliant with the supplier's
specification
Pump rotor blocked
Air in the installation
Unlock the rotor
UTILISATION
The used product is subject to disposal as wastes only in selective waste collection systems organised
by the Network of Communal Electric and Electronic Waste Collection Centres. The customer is
entitled to return the used equipment to the network of the electric equipment distributor, at least for
free and directly, if the returned device is of proper type and fulfils the same function as a newly purchased device. It is
prohibited to dispose of electric equipment together with other household waste.
Gawartowa Wola 23.01.2021
Adam Jastrzębski
Vent the installation
Flow too high
Decrease the inflow pressure at
the pump inlet
Loud pump operation
Air in the pump
Vent it
I
nflow pressure too low - cavitation
Increase the inflow pressure at the inlet to
the
pump
Pump parameters too low
If possible, increase the pump operation
mode into a more efficient one, otherwise
install stronger pump
USE AND CARE GUIDE IVO
EC DECLARATION OF CONFORMITY (Moduł A):
1.Circulating pumps IVO 25-40/180, IVO 25-60/180, IVO 25-60/130,
2.
PHU Dambat, Gawartowa Wola 38, 05-085 KAMPINOS, POLAND, e-mail:
This declaration of conformity is issued under the sole responsibility of the manufacturer.
4. Pumps form point 1.
5.
We declare with full responsibility that pumps included in the point 1. to which this declaration refers to are
consistentwith the following guidelines of the Council on legal regulations unification in member states of EC:
- Directive EMC No. 2014/30/EU
- Directive LVD No. 2014/35/EU
- Directive MD No. 2006/42/EC
- Directive ErP No. 2009/125/EC.
6. Applied standards:
EN 60204-1:2006+A1:2009+AC2010, EN 809:1998+A1:2009+AC:2010, EN 62233:2008, EN 16277-1:2012,
EN 16277-2:2012, EN 16277-3:2012,EN 60335-1:2012+A11:2014+A13:2017, EN 60335-2-41:2003+A1:2004
+A2:2010,EN 55014-1:2017, EN5014-2:2015, EN 61000-3-2:2019, EN 61000-3-3:2013+A1:2019