INSTALLATION
In installation, please pay attention to the flow direction of the heating medium. An arrow on the pump body shows
the flow direction forced by the pump. That direction must be compliant with the circulation of the medium in the
system.
The pump should be installed in such a way that the pump shaft is horizontal.
12
ELECTRIC CONNECTION
The electric connection and protection must follow the local regulations.
The electric pump m. be connected to an earthing conductor. Power supply breaker. The minimum slit between the pins
of the breaker must be 3 mm.
!
• E-IBO series circulation pump does not require any
external motor guards.
• Check if the power supply voltage and frequency are
compliant with the parameters specified on the rating
plate.
• Use the special plug supplied with the pump to connect
the power supply cable.
• If the control signal on the control panel illuminates, the
power supply is switched on.
CONTROL PANEL
Control Panel Elements
Function description:
1
3
A knob that sets the
intensity of the flow (the
color of the diode green)
2
Gear setting indicator
Economy mode
automatically adjusts the s
peed in Depending on the
type of system (orange color)
Diode indicating operating
mode
4
USE AND CARE GUIDE E-IBO