The  Pump  cannot  operate  “dry”  without  water.  “Dry” 
operation  can  lead  to  device  damage.  In  such  a case, 
only paid repair is available. 

In  order  to  avoid  potential  dry  operation,  the  pump  must  be 
installed at such a depth so that the lowest, dynamic mirror level 
(the mirror level set at the time of constant pumping with slow 
inflow) was at least 2 m above the discharge port. 

If the well efficiency disables such installation (the well is not efficient enough in relation to pump 
efficiency), then you can choose one of the following solutions: 

 install a valve on the pumping pipeline that will constantly limit the flow, 

install a security device protecting against dry operation, monitoring the water mirror 
level  which  in  case  of  dry  operation  hazard  will  switch  off  power  supply  to  the 
aggregate. 

The use of the pump in a well with wider diameter than 
shown in the table can result in motor overheating and its 
failure.  If  the  well  in  which  the  pump  is  to  operate  has 
wider diameter than specified in the table, the pump must 
be installed in a special jacket forcing the proper cooling. 
In pic. the idea of such a jacket is presented. 
The pump must be installed in the well section above the 
filter.  The  minimal  distance  between  the  upper  edge  of 
the top part of the well filter and the bottom edge of the 
motor  cannot  be  smaller  than  30  cm.  The  use  of  the 
pump  installed  nearer  to  the  bottom  can  result  in  sand 
suction which, in turn, can lead to faster wear and tear of 
pumping elements. If the pump is placed in sludge, it can 
result in motor overheating. 

When lowering the pump into the well, attention must be paid that the supply cable of 
the pump is fixed to the supply pipe with plastic bands in spans not exceeding 2 m. 

In case of significant depth of pump installation, the cable which is not attached to the 
delivery pipeline can, due to its weight, be broken. 

 

It  is  also  recommended  that  the  pump  is  suspended  on  a  steel  line  so  that  if  the 
delivery pipeline gets unscrewed, the aggregate does not sink in the well. 

The  check  valve  protecting  the  device  against  impacts  of  returning  water  must  be 
installed directly above the pump. 

The pump motor is filled with ecological oil. In case of motor failure, the oil can leak into 
the well. 

 

 

 

 

 

Содержание 3SDm

Страница 1: ...ended for use by persons including children with reduced motor sensory or mental capacities or persons without experience or not familiarised with the equipment unless it is performed under supervisio...

Страница 2: ...in two elements One element is a hydraulic part of the pump the other is a motor Prior to connection of two elements the clamping screws must be unscrewed from the strip protecting the cable Next the...

Страница 3: ...p is to operate has wider diameter than specified in the table the pump must be installed in a special jacket forcing the proper cooling In pic the idea of such a jacket is presented The pump must be...

Страница 4: ...with rated making current In not exceeding 30 mA The manufacturer and guarantor are not liable for any damage to people or property resulting from supplying the pump with power without a proper switch...

Страница 5: ...assign such installation to a well fitter or they can do it in the shop of the well purchase Unprofessional connection and insulation of the cables can lead to automatic trigger of the residual curren...

Страница 6: ...R 4SD 4SDm 3 5 SCM 3 5 SCR 90MSC 4SKt 3SQIBO DWP STING SPm SP 3 SCR 4ISP 6ISP 4ISPM FL OLA STm to which this declaration refers to are consistent with the following guidelines of the Council on legal...

Страница 7: ...d the level onto which the water is pumped the length of the pumping pipeline hose and its diameter are factors which influence the height of lifting that must be performed by the pump If the resistan...

Страница 8: ......

Отзывы: