Power-on LED:
See “Operator information panel” on page 12 for the various states
of the power-on LED.
System-error LED:
When this LED is lit, it indicates that a system error has
occurred. An LED on the light path diagnostics panel is also lit to help isolate the
error.
Locator LED:
Use this LED to visually locate the server among other servers. You
an use IBM Systems Director to light this LED remotely.
Server power features
When the server is connected to an ac power source but is not turned on, the
operating system does not run, and all core logic except for the integrated
management module (IMM) is shut down; however, the server can respond to
requests from the IMM, such as a remote request to turn on the server. The
power-on LED flashes to indicate that the server is connected to ac power but not
turned on.
Turning on the server
Approximately 3 minutes after the server is connected to ac power, the
power-control button becomes active, and one or more fans might start running to
provide cooling while the server is connected to power. You can turn on the server
and start the operating system by pressing the power-control button.
The server can also be turned on in any of the following ways:
v
If a power failure occurs while the server is turned on, the server will restart
automatically when power is restored.
v
The systems-management software can turn on the server remotely.
v
If your operating system supports the Wake on LAN feature, the Wake on LAN
feature can turn on the server.
Note:
Some memory is reserved for various system resources and is unavailable
to the operating system. The amount of memory that is reserved for system
resources depends on the operating system, the configuration of the server, and the
configured PCI options.
Turning off the server
When you turn off the server and leave it connected to ac power, the server can
respond to requests from the IMM, such as a remote request to turn on the server.
While the server remains connected to ac power, one or more fans might continue
to run. To remove all power from the server, you must disconnect it from the power
source.
Important:
To view the error LEDs on the system board, leave the server
connected to a power source.
Some operating systems require an orderly shutdown before you turn off the server.
See your operating-system documentation for information about shutting down the
operating system.
16
IBM System x3850 X5 and x3950 X5 Types 7145 and 7146: Installation and User’s Guide
Содержание x3850 X5 7145
Страница 1: ...IBM System x3850 X5 and x3950 X5 Types 7145 and 7146 Installation and User s Guide...
Страница 2: ......
Страница 3: ...IBM System x3850 X5 and x3950 X5 Types 7145 and 7146 Installation and User s Guide...
Страница 32: ...18 IBM System x3850 X5 and x3950 X5 Types 7145 and 7146 Installation and User s Guide...
Страница 101: ......
Страница 102: ...Part Number 59Y7205 Printed in USA 1P P N 59Y7205...