LED
Description
Action
PS
2
The
power
supply
in
bay
2
has
failed.
Attention:
In
a
dc
power
environment,
only
trained
service
personnel
other
than
IBM
service
technicians
are
authorized
to
connect
or
disconnect
power
to
the
dc
power
supply
and
to
remove
and
install
a
dc
power
supply.
See
the
documentation
that
comes
with
each
dc
power
supply.
1.
Make
sure
that
the
power
supply
is
correctly
seated.
2.
Replace
the
failed
power
supply.
CPU
A
microprocessor
has
failed.
1.
Make
sure
that
the
failing
microprocessor,
which
is
indicated
by
a
lit
LED
on
the
system
board,
is
installed
correctly.
See
the
User’s
Guide
on
the
IBM
System
x
Documentation
CD
for
information
about
installing
a
microprocessor.
2.
Call
for
service.
VRM
An
error
occurred
on
the
microprocessor
voltage
regulator
module
(VRM).
1.
Replace
the
VRM.
2.
Call
for
service.
CNFG
A
hardware
configuration
error
has
occurred.
1.
Check
the
microprocessors
that
were
just
installed
to
make
sure
that
they
are
compatible
with
each
other
and
with
the
VRM
(see
“Installing
an
additional
microprocessor”
on
page
20
for
compatiblity
requirements).
2.
(Trained
service
technician
only)
Replace
an
incompatible
microprocessor.
3.
Check
the
system
error
logs
for
information
about
the
error.
Replace
any
components
that
are
indicated.
(Use
the
Configuration/Setup
Utility
program
to
view
the
error
logs.)
MEM
A
memory
error
has
occurred.
Replace
the
failing
DIMM,
which
is
indicated
by
the
lit
LED
on
the
system
board.
NMI
A
machine
check
error
has
occurred.
Check
the
system-error
log
for
information
about
the
error.
(Use
the
Configuration/Setup
Utility
program
to
view
the
error
logs.)
S
ERR
Reserved.
SP
The
service
processor
has
failed.
Attention:
In
a
dc
power
environment,
only
trained
service
personnel
other
than
IBM
service
technicians
are
authorized
to
connect
or
disconnect
power
to
the
dc
power
supply.
See
the
documentation
that
comes
with
each
dc
power
supply.
1.
Remove
power
from
the
server;
then,
reconnect
the
server
to
power
and
restart
the
server.
2.
Update
the
firmware
on
the
BMC.
3.
If
a
Remote
Supervisor
Adapter
II
SlimLine
is
installed,
update
the
firmware;
if
the
problem
remains,
replace
the
adapter.
4.
Call
for
service
DASD
A
hard
disk
drive
error
has
occurred.
1.
Check
the
LEDs
on
the
hard
disk
drives
and
replace
the
indicated
drive.
2.
Call
for
service.
76
IBM
System
x3650
Type
7979:
Installation
Guide
Содержание x3650 - System M2 - 7947
Страница 3: ...IBM System x3650 Type 7979 Installation Guide...
Страница 22: ...8 IBM System x3650 Type 7979 Installation Guide...
Страница 72: ...58 IBM System x3650 Type 7979 Installation Guide...
Страница 92: ...78 IBM System x3650 Type 7979 Installation Guide...
Страница 102: ...88 IBM System x3650 Type 7979 Installation Guide...
Страница 106: ...92 IBM System x3650 Type 7979 Installation Guide...
Страница 107: ......
Страница 108: ...Part Number 44R5190 Printed in USA 1P P N 44R5190...