![IBM x3500 - System - 7977 Скачать руководство пользователя страница 80](http://html2.mh-extra.com/html/ibm/x3500-system-7977/x3500-system-7977_installation-manual_4733447080.webp)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
Problem
Determination
and
Service
Guide
on
the
IBM
System
x
Documentation
CD
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
175
Service
processor
flash
code
damaged
or
not
installed.
Note:
In
this
case,
the
service
processor
is
the
optional
Remote
Supervisor
Adapter
II
SlimLine.
1.
Update
the
Remote
Supervisor
Adapter
II
firmware
(see
the
Problem
Determination
and
Service
Guide
on
the
IBM
System
x
Documentation
CD).
2.
Replace
the
Remote
Supervisor
Adapter
II
SlimLine.
184
Power-on
password
damaged.
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
and
save
the
settings.
2.
Clear
CMOS
memory.
See
the
Problem
Determination
and
Service
Guide
on
the
IBM
System
x
Documentation
CD
for
information
about
how
to
clear
CMOS
memory.
3.
Reseat
the
battery.
4.
Replace
the
following
components,
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
187
VPD
serial
number
not
set.
1.
Set
the
serial
number
by
updating
the
BIOS
code
level
(see
the
Problem
Determination
and
Service
Guide
on
the
IBM
System
x
Documentation
CD).
2.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine.
3.
Replace
the
following
components,
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Remote
Supervisor
Adapter
II
SlimLine
b.
(Trained
service
technician
only)
System
board
188
Remote
Supervisor
Adapter
II
SlimLine
EEPROM
error
Replace
the
Remote
Supervisor
Adapter
II
SlimLine.
189
An
attempt
was
made
to
access
the
server
with
an
incorrect
password.
Restart
the
server
and
enter
the
administrator
password;
then,
run
the
Configuration/Setup
Utility
program
and
change
the
power-on
password.
Note:
If
you
forgot
the
power-on
password
or
administrator
password,
you
can
change
the
position
of
the
jumper
on
pin
2
on
SW4
to
the
ON
position
to
bypass
the
password
check.
This
enables
you
to
reset
the
passwords.
196
Microprocessors
do
not
have
the
same
L2
or
L3
cache
size.
Install
microprocessors
with
the
same
L2
or
L3
cache
size.
Note:
Do
not
mix
dual-core
and
quad-core
processors
in
the
same
system.
66
IBM
System
x3500
Type
7977:
Installation
Guide
Содержание x3500 - System - 7977
Страница 3: ...IBM System x3500 Type 7977 Installation Guide...
Страница 14: ...xii IBM System x3500 Type 7977 Installation Guide...
Страница 48: ...34 IBM System x3500 Type 7977 Installation Guide...
Страница 76: ...62 IBM System x3500 Type 7977 Installation Guide...
Страница 118: ...104 IBM System x3500 Type 7977 Installation Guide...
Страница 122: ...108 IBM System x3500 Type 7977 Installation Guide...
Страница 123: ......
Страница 124: ...Part Number 44R5218 Printed in USA 1P P N 44R5218...