v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
Problem
Determination
and
Service
Guide
on
the
IBM
System
x
Documentation
CD
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Lit
light
path
diagnostics
LED
with
the
system-error
or
information
LED
also
lit
Description
Action
PCI
BUS
A
PCI
adapter
has
failed.
1.
See
the
BMC
log
or
the
system-error
log
(see
the
Problem
Determination
and
Service
Guide
on
the
IBM
System
x
Documentation
CD).
2.
Reseat
the
failing
adapter.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Failing
adapter
b.
(Trained
service
technician
only)
System
board
NMI
A
hardware
error
has
been
reported
to
the
operating
system.
Note:
The
PCI
or
MEM
LED
might
also
be
lit.
1.
See
the
BMC
log
and
the
system-error
log
(see
the
Problem
Determination
and
Service
Guide
on
the
IBM
System
x
Documentation
CD).
2.
If
the
PCI
LED
is
lit,
follow
the
instructions
for
that
LED.
3.
If
the
MEM
LED
is
lit,
follow
the
instructions
for
that
LED.
4.
Restart
the
server.
94
IBM
System
x3500
Type
7977:
Installation
Guide
Содержание x3500 - System - 7977
Страница 3: ...IBM System x3500 Type 7977 Installation Guide...
Страница 14: ...xii IBM System x3500 Type 7977 Installation Guide...
Страница 48: ...34 IBM System x3500 Type 7977 Installation Guide...
Страница 76: ...62 IBM System x3500 Type 7977 Installation Guide...
Страница 118: ...104 IBM System x3500 Type 7977 Installation Guide...
Страница 122: ...108 IBM System x3500 Type 7977 Installation Guide...
Страница 123: ......
Страница 124: ...Part Number 44R5218 Printed in USA 1P P N 44R5218...