9.
Take
the
other
end
of
the
signal
cable
that
is
attached
to
the
drive
backplane
section
for
drive
bays
0
through
3
(as
labeled
on
the
front
of
the
drive
cage)
and
connect
it
to
the
connector
that
is
closest
to
the
battery
on
the
ServeRAID-MR10i
SAS/SATA
controller.
If
drives
are
installed
in
drive
bays
4
through
7
(as
labeled
on
the
front
of
the
drive
cage),
take
the
other
end
of
the
signal
cable
that
is
attached
to
drive
backplane
section
for
drive
bays
4
through
7
and
connect
it
to
the
connector
that
is
farthest
from
the
battery
on
the
ServeRAID-MR10i
SAS/SATA
controller.
10.
Replace
the
hard
disk
drive
fan
assembly:
a.
Insert
the
hard
disk
drive
fan
assembly
retaining
tab
over
the
right
edge
of
the
hard
disk
drive
backplane;
then,
rotate
the
hard
disk
drive
fan
assembly
toward
the
backplane.
Do
not
fully
close
the
hard
disk
drive
fan
assembly.
b.
Route
the
signal
cables
and
power
cable
through
the
slot
on
the
edge
of
the
hard
disk
drive
fan
assembly.
Make
sure
that
the
cables
will
not
be
pinched
between
the
hard
disk
drive
fan
assembly
and
the
hard
disk
drive
backplane
when
the
assembly
is
installed.
c.
Rotate
the
hard
disk
drive
fan
assembly
toward
the
backplane
until
the
release
tabs
are
fully
engaged
and
snap
into
place.
11.
Reconnect
the
hard
disk
drive
fan
assembly
cable
to
the
system
board.
12.
Rotate
the
drive
cage
back
into
the
server
until
it
stops;
then,
press
and
hold
the
retaining
tab
on
top
of
the
drive
cage
while
you
rotate
the
drive
cage
into
the
chassis
until
it
is
in
the
closed
position.
13.
Reinstall
the
hard
disk
drives.
Note:
Before
you
continue,
check
all
internal
power
cables
to
make
sure
that
they
are
connected
to
the
system
board
and
other
optional
devices.
14.
Install
the
side
cover
(see
“Reinstalling
the
side
cover”
on
page
54).
15.
Lock
the
side
cover.
16.
Reconnect
the
external
cables
and
power
cords;
then,
turn
on
the
attached
devices
and
turn
on
the
server.
Installing
an
optional
mini-PCI-X
enablement
card
To
install
an
optional
mini-PCI-X
enablement
card,
complete
the
following
steps:
1.
Read
the
safety
information
that
begins
on
page
v
and
“Installation
guidelines”
on
page
20.
2.
Turn
off
the
server
and
all
attached
devices;
then,
disconnect
all
power
cords
and
external
cables.
3.
Unlock
and
remove
the
side
cover
(see
“Removing
the
side
cover”
on
page
24).
4.
Touch
the
static-protective
package
that
contains
the
mini-PCI-X
enablement
card
to
any
unpainted
surface
on
the
outside
of
the
server;
then,
remove
mini-PCI-X
enablement
card
from
the
package.
5.
Position
the
mini-PCI-X
enablement
card
over
the
mini-PCI
slot
connector
and
the
plastic
standoff.
Press
the
mini-PCI-X
enablement
card
firmly
into
the
mini-PCI
slot
connector
and
into
the
mini-PCI-X
enablement
card
connector,
and
then
onto
the
plastic
standoff.
46
System
x3200
M2
Types
4367
and
4368:
User’s
Guide
Содержание x3200 M2 Type 4367
Страница 1: ...System x3200 M2 Types 4367 and 4368 User s Guide...
Страница 2: ......
Страница 3: ...System x3200 M2 Types 4367 and 4368 User s Guide...
Страница 28: ...14 System x3200 M2 Types 4367 and 4368 User s Guide...
Страница 88: ...74 System x3200 M2 Types 4367 and 4368 User s Guide...
Страница 100: ...86 System x3200 M2 Types 4367 and 4368 User s Guide...
Страница 101: ......
Страница 102: ...Part Number 43W7063 Printed in USA 1P P N 43W7063...