Table
4.
Web/SNMP
card
configuration
parameters
with
examples
(continued)
Menu
option
number
Function
Description
Example
4
sysContact
System
contact
string
of
MIB
(up
to
127
characters)
Powerware
5
sysName
System
name
parameter
for
MIB
(up
to
127
characters
Web/SNMP
card
6
sysLocation
System
location
parameter
for
MIB
(up
to
127
characters)
TEST
LAB
Set
Web/SNMP
card
control
group
To
use
BOOTP/DHCP,
Telnet,
or
secure
HTTP
to
configure,
control,
update,
or
manage
the
Web/SNMP
card,
you
must
enable
or
disable
certain
control
parameters.
Select
option
2
to
modify
the
parameters.
Notes:
1.
To
prevent
unauthorized
viewing
of
the
Web
pages
that
are
displayed
by
the
Web/SNMP
Card,
use
option
2
to
enable
HTTP
Security
Control.
2.
To
obtain
an
IP
address
using
BOOTP/DHCP
(instead
of
serial
configuration),
set
DIP
Switch
2
on
the
front
panel
of
the
Web/SNMP
card
to
the
On
position
(Off
is
the
default).
Set
write
access
managers
To
use
an
SNMP-compatible
NMS
to
manage
the
Web/SNMP
card,
you
must
add
the
IP
address
of
the
management
station
to
the
list
on
the
Web/SNMP
card
to
receive
read
(get)
or
write
(set)
access
rights.
Select
option
3
to
add
or
delete
the
IP
address
of
the
management
station.
Community
strings
might
be
different
for
read
or
write
access.
Set
trap
receivers
To
use
an
SNMP-compatible
NMS
to
manage
the
Web/SNMP
card,
you
must
add
the
IP
address
of
the
workstation
intended
to
be
the
trap
receiver
to
the
list
on
the
Web/SNMP
Card.
Select
option
3
to
add
or
delete
the
IP
address
of
the
trap
receivers.
You
can
modify
this
information
through
the
HTTP
interface
after
the
card
is
connected
to
the
network.
Set
IP
addresses
of
primary
and
secondary
date
server
Computer
systems
with
the
Web/SNMP
card-compatible
NetWatch
client
software
are
periodically
monitored
by
the
Web/SNMP
card
to
maintain
a
consistent
date
and
time
with
your
network.
The
IP
address
of
the
computer
must
be
listed
as
the
primary
or
secondary
date
server.
To
set
the
IP
addresses
of
the
primary
and
secondary
date
servers,
select
option
5
.
You
can
modify
this
information
through
the
HTTP
interface
after
the
card
is
connected
to
the
network.
UPS
event
actions
To
configure
actions
that
the
Web/SNMP
card
performs
during
an
ac
power
failure
and
low
battery
events,
select
option
6
.
You
can
modify
this
information
through
the
HTTP
interface
after
the
card
is
connected
to
the
network.
30
UPS
3000
LV
and
UPS3000
HV:
Installation
and
Maintenance
Guide
Содержание UPS3000 LV
Страница 1: ...UPS3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 2: ......
Страница 3: ...UPS3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 28: ...16 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 36: ...24 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 46: ...34 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 54: ...42 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 80: ...68 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 83: ......
Страница 84: ...Part Number 40K9691 Printed in USA 1P P N 40K9691...