
+===================================================================
|
[
ConnectUPS
Web/SNMP
Card
Configuration
Utility
]
+===================================================================
1.
Web/SNMP
Card
Settings
2.
Reset
Configuration
to
default
3.
Restart
Web/SNMP
Card
4.
UPS
Pass-Through
0.
Exit
Please
Enter
Your
Choice
=>1
+===================================================================
|
[
ConnectUPS
Web/SNMP
Card
Configuration
Utility
]
+===================================================================
1.
Set
the
IP
Address,
Gateway
Address
and
MIB
System
Group
2.
Set
Web/SNMP
Card
Control
Group
3.
Set
Write
Access
Managers
4.
Set
Trap
Receivers
5.
Set
IP
Addresses
of
Primary
and
Secondary
Date
Server
6.
UPS
Event
Actions
7.
Set
UPS
Information
8.
Set
Superuser
Name
and
Password
9.
Notification
10.
Set
Website
Links
11.
Card
Settings
and
Event
Log
Summary
12.
Set
External
Contact
Monitoring
0.
Back
to
Main
Menu
Please
Enter
Your
Choice
=>_
2.
Type
1
to
open
the
Set
the
IP
Address,
Gateway
Address
and
MIB
System
Group
screen.
Enter
the
applicable
settings
for
your
network
(see
Table
4).
3.
Change
any
other
options
as
needed
for
your
particular
configuration
by
typing
the
corresponding
number
in
the
menu
(2
through
10).
Each
setting
is
described
in
the
following
sections.
4.
Type
0
to
return
to
the
Main
Menu.
5.
Type
0
to
exit
the
Web/SNMP
Card
Configuration
Utility.
The
Web/SNMP
card
automatically
saves
all
settings
after
exiting
the
configuration
utility.
Notes:
1.
The
Web/SNMP
card
can
take
up
to
two
minutes
to
establish
communication
with
the
uninterruptible
power
supply.
Wait
before
attempting
communication
with
the
card
from
a
Web
browser
or
network
management
system
(NMS).
2.
For
Telnet
operation:
After
the
card
is
accessible
on
the
network,
you
can
use
a
Telnet
utility
to
modify
any
of
the
configuration
settings.
The
menus
are
identical
to
those
seen
during
serial
configuration
and
are
password-protected
for
Superuser
access
only.
Set
the
IP
address,
gateway
address,
and
MIB
system
group
To
set
the
IP
address,
the
gateway
address,
or
the
management
information
base
(MIB)
parameters
of
the
card,
select
option
1
.
The
following
table
lists
the
Web/SNMP
card
parameters.
Table
4.
Web/SNMP
card
configuration
parameters
with
examples
Menu
option
number
Function
Description
Example
1
IP
address
IP
address
of
the
Web/SNMP
card
192.72.173.188
2
Gateway
address
Default
IP
address
of
the
network
gateway
192.72.173.254
3
Network
mask
Subnet
mask
setting
255.255.255.0
Chapter
4.
Using
the
Web/SNMP
card
29
Содержание UPS3000 LV
Страница 1: ...UPS3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 2: ......
Страница 3: ...UPS3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 28: ...16 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 36: ...24 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 46: ...34 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 54: ...42 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 80: ...68 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide...
Страница 83: ......
Страница 84: ...Part Number 40K9691 Printed in USA 1P P N 40K9691...