Note:
Allow at least 60 cm (2 ft) of clearance in front of and behind the FAStT900
Storage Server for proper ventilation.
Servicing notes
Consider the following factors when you service the storage server fan:
v
The storage server fan and the fan and communications module cooling system
failing simultaneously in the storage server is unlikely. Such a failure will cause
either one or both controllers to overheat. Under these circumstances, the amber
controller light on the front panel might be lit. If this occurs, shut down the
FAStT900 Storage Server immediately and let the unit cool to room temperature
and then replace the storage server fan.
v
You can hot swap, or replace, the storage server fan, as long as you complete
the exchange within 15 minutes. The time limit applies to the total time that the
fan is out of the chassis. The time begins when you remove the failed storage
server fan and ends when you install the new one. This does not include the time
it takes to perform the entire procedure (for example, checking the indicator
lights).
v
When a storage server fan fails, the fault light on the storage server fan is lit. For
more information about indicator lights, see “Storage server indicator lights” on
page 20.
v
If you replace the storage server fan and still experience problems, the FAStT900
Storage Server might have defective components or connections. Check the
storage-management software for indications of other component failures.
v
The storage server fan indicator light is also used to indicate a fan and
communications module failure. Be sure to check the storage server fan and fan
and communications module before you call for service.
Replacing a failed storage server fan
When instructed by the storage-management software, replace the storage server
fan.
1. Remove the FAStT900 Storage Server bezel, as shown in Figure 21 on
page 16.
Figure 39. FAStT900 Storage Server airflow
Chapter 3. Replacing the FAStT900 Storage Server components
45
Содержание TotalStorageFAStT900
Страница 2: ......
Страница 3: ...IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide GC26 7534 00 ...
Страница 7: ...IBM license agreement for Machine Code 70 Glossary 71 Index 79 Contents v ...
Страница 8: ...vi IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Страница 10: ...viii IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Страница 12: ...x IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Страница 18: ...xvi IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Страница 62: ...36 IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Страница 86: ...60 IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Страница 108: ...82 IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Страница 111: ......
Страница 112: ... Part Number 32P0341 Printed in U S A GC26 7534 00 1P P N 32P0341 ...