7.
Select
the
Recovery
Guru
toolbar
button.
Perform
the
procedure
in
the
Recovery
Guru
to
correct
the
problem.
The
Recovery
Guru
might
direct
you
to
replace
the
failed
component;
if
so,
go
to
step
otherwise
continue
with
step
8.
Check
the
LEDs
on
the
storage
subsystem
to
determine
if
a
fault
has
occurred
in
the
storage
subsystem.
For
the
definition
of
the
LED
statuses,
see
9.
Are
any
Needs
Attention
LEDs
indicating
a
fault
condition?
v
Yes
–
Go
to
step
v
No
–
You
are
finished
with
this
procedure.
If
you
are
still
experiencing
a
problem
with
this
storage
subsystem,
go
to
step
10.
Replace
the
failed
component.
For
instructions
on
replacing
the
controllers,
power
supply
and
fan
units,
interconnect-battery,
battery
pack,
and
SFP
modules,
see
11.
If
the
problem
has
not
been
fixed,
contact
your
IBM
service
representative.
a
storage
subsystem
profile,
and
save
the
storage
subsystem
support
data.
The
profile
and
support
data
are
helpful
when
troubleshooting
storage
subsystem
problems.
(For
information
about
printing
a
storage
subsystem
profile
and
saving
the
support
data,
refer
to
the
Subsystem
Management
window
online
help.)
Checking
the
LEDs
The
LEDs
display
the
status
of
the
storage
subsystem
and
components.
Green
LEDs
indicate
a
normal
operating
status;
amber
LEDs
(Needs
Attention)
indicate
a
possible
failure;
a
blue
LED
indicates
that
is
safe
to
remove
a
component.
It
is
important
to
check
all
the
LEDs
on
the
front
and
back
of
the
storage
subsystem
when
you
turn
on
the
power.
In
addition
to
checking
for
faults,
you
can
use
the
LEDs
on
the
front
of
the
storage
expansion
enclosures
to
determine
if
the
drives
are
responding
to
I/O
transmissions
from
the
host.
Front
bezel
LEDs
You
must
remove
the
front
bezel
in
order
to
see
all
of
the
interconnect-battery
unit
LEDs.
With
the
bezel
in
place,
only
the
following
LEDs
are
visible:
v
Power
v
Overall
DS4800
Configuration
Needs
Attention
v
Locate/Identify
Important:
The
displayed
order
of
the
Overall
DS4800
Configuration
Needs
Attention
and
Locate/Identify
LEDs
on
the
interconnect-battery
unit
are
reversed
when
the
bezel
is
removed.
See
118
IBM
System
Storage
DS4800
Storage
Subsystem:
Installation,
User’s,
and
Maintenance
Guide
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 01...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 168: ...140 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 216: ...188 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 220: ...192 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 240: ...212 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 246: ...218 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 249: ......
Страница 250: ...Part Number 22R6614 Printed in USA GC26 7845 01 1P P N 22R6614...