background image

Drive

 

interface

 

ports

 

DS4500

 

Storage

 

Subsystems

 

use

 

only

 

redundant

 

drive-loop

 

configurations.

 

Each

 

drive

 

mini

 

hub

 

connects

 

to

 

Controller

 

A

 

and

 

Controller

 

B

 

and

 

represents

 

a

 

single

 

drive

 

loop.

 

The

 

drive

 

loops

 

must

 

be

 

set

 

up

 

in

 

pairs

 

to

 

support

 

redundant

 

drive

 

loop

 

configurations

 

(two

 

data

 

paths

 

per

 

storage

 

expansion

 

enclosure).

 

See

 

Figure

 

4

 

for

 

an

 

illustration

 

of

 

the

 

drive-side

 

mini-hub

 

interface

 

ports.

 

The

 

maximum

 

number

 

of

 

storage

 

expansion

 

enclosures

 

that

 

can

 

be

 

connected

 

per

 

pair

 

of

 

redundant

 

drive

 

loops

 

depends

 

on

 

the

 

IBM

 

DS4000

 

storage

 

expansion

 

enclosure

 

models

 

used.

 

The

 

following

 

DS4000

 

storage

 

expansion

 

enclosure

 

types

 

are

 

supported

 

by

 

the

 

DS4500

 

Storage

 

Subsystem:

 

v

   

FAStT

 

EXP500

 

v

   

DS4000

 

EXP700

 

v

   

DS4000

 

EXP710

 

v

   

DS4000

 

EXP100

 

v

   

DS4000

 

EXP810

 

If

 

the

 

drives

 

are

 

configured

 

using

 

only

 

DS4000

 

EXP700,

 

EXP710,

 

EXP810,

 

or

 

EXP100

 

storage

 

expansion

 

enclosures,

 

the

 

DS4500

 

Storage

 

Subsystem

 

supports

 

a

 

maximum

 

of

 

224

 

hard

 

drives.

 

If

 

the

 

drives

 

are

 

configured

 

using

 

only

 

FAStT

 

EXP500

 

storage

 

expansion

 

enclosures,

 

the

 

DS4500

 

Storage

 

Subsystem

 

supports

 

a

 

maximum

 

of

 

220

 

hard

 

drives.

 

Important

:

 

Ensure

 

that

 

the

 

single

 

digit

 

(x1)

 

of

 

the

 

enclosure

 

ID

 

for

 

every

 

enclosure

 

in

 

a

 

redundant

 

drive

 

loop

 

pair

 

is

 

unique.

 

Refer

 

to

 

the

 

IBM

 

TotalStorage

 

DS4500

 

Installation,

 

User's,

 

and

 

Maintenance

 

Guide

 

for

 

more

 

information

 

on

 

the

 

storage

 

expansion

 

enclosure

 

IDs

 

settings.

 

To

 

cable

 

two

 

DS4000

 

10-

 

or

 

14-

 

drive

 

storage

 

expansion

 

enclosures

 

(EXP500,

 

EXP700,

 

EXP710,

 

or

 

EXP100)

 

to

 

the

 

DS4500,

 

see

 

“Connecting

 

to

 

EXP500/EXP100/EXP700/EXP710

 

storage

 

expansion

 

enclosures”

 

on

 

page

 

7.

 

To

 

cable

 

two

 

DS4000

 

16-drive

 

storage

 

expansion

 

enclosures

 

(EXP810)

 

to

 

the

 

DS4500,

 

see

 

“Connecting

 

to

 

EXP810

 

storage

 

expansion

 

enclosures”

 

on

 

page

 

8.

 

OUT

IN

!

2 Gb/s
1 Gb/s

OUT

IN

!

2 Gb/s
1 Gb/s

OUT

IN

!

2 Gb/s
1 Gb/s

OUT

IN

!

2 Gb/s
1 Gb/s

OUT

IN

!

2 Gb/s
1 Gb/s

OUT

IN

!

2 Gb/s
1 Gb/s

OUT

IN

!

2 Gb/s
1 Gb/s

OUT

IN

!

2 Gb/s
1 Gb/s

Drive
mini-hub
ports

Drive loop C and D for
redundant drive loop pair 2

Drive loop A and B for
redundant drive loop pair 1

4

Use one port on each
mini hub to connect
a drive loop cable

Leave one port unoccupied
for future upgrades

GS000043

3

2

1

  

Figure

 

4.

 

Drive

 

mini-hub

 

ports

 

6

Содержание TotalStorage DS4500

Страница 1: ...ad All drives in the connected storage expansion enclosure s must contain no prior configuration data Table 1 Installation Tasks Task Detailed Description 1 Review the DS4500 installation recommendati...

Страница 2: ...t FC HBAs Chapter 3 Connecting hosts to the DS4500 11 Connect the power cables for the DS4500 and the storage expansion enclosures if needed Chapter 3 Cabling the power supply 12 Power on the attached...

Страница 3: ...Attention Remove SFP modules from any unused mini hub ports both host side and drive side on the DS4500 Storage Subsystem To avoid damage to your fibre optic cables v Do not route the cable along a f...

Страница 4: ...closures in the rack cabinet before cabling the configuration OUT IN 2 Gb s 1 Gb s OUT IN 2 Gb s 1 Gb s OUT IN 2 Gb s 1 Gb s OUT IN 2 Gb s 1 Gb s OUT IN 2 Gb s 1 Gb s OUT IN 2 Gb s 1 Gb s OUT IN 2 Gb...

Страница 5: ...cabling refer to the IBM TotalStorage DS4500 Fibre Channel Storage Subsystem Installation User s and Maintenance Guide Drive side fibre channel cabling The DS4500 Storage Subsystem supports up to two...

Страница 6: ...y FAStT EXP500 storage expansion enclosures the DS4500 Storage Subsystem supports a maximum of 220 hard drives Important Ensure that the single digit x1 of the enclosure ID for every enclosure in a re...

Страница 7: ...left ESM board of the second enclosure Connect the In port on the right ESM board of the first enclosure to the Out port on the right ESM board of the second enclosure If you want to connect addition...

Страница 8: ...ng with the second storage expansion enclosure connect each additional storage expansion enclosure into drive loops A and B in the same manner Leave port 1A on the ESM B board on the last storage expa...

Страница 9: ...cupied The EXP810 enclosure IDs will automatically set to give each enclosure in the drive loop a unique enclosure ID EXP810 ESM B ESM A EXP810 ESM B ESM A EXP810 ESM B ESM A EXP810 ESM B ESM A Port 1...

Страница 10: ...This page left intentionally blank 10...

Страница 11: ...This page left intentionally blank 11...

Страница 12: ...torage Other company product or service names may be trademarks or service marks of others Second edition October 2006 Copyright International Business Machines Corporation 2006 All rights reserved US...

Отзывы: