1.
Turn
off
the
power
switches
to
allow
the
DS4400
Storage
Server
to
cool.
2.
When
the
room
temperature
is
below
the
upper
operating
temperature
of
35°
C
(95°
F),
turn
on
the
power
switches.
3.
Check
the
DS4400
Storage
Server
for
faults
or
damage.
Use
the
storage-management
software
to
check
the
overall
status
of
the
DS4400
Storage
Server
and
its
components.
Correct
any
problems
indicated.
Turning
on
the
power
after
an
emergency
shutdown
Use
this
procedure
to
regain
normal
system
operation
after
a
power
failure
or
emergency
shutdown.
1.
Check
all
components
and
cables
for
damage.
If
there
is
no
visible
damage,
continue
with
Step
2;
otherwise,
service
the
system.
2.
Make
sure
the
power
cords
are
plugged
in.
3.
Make
sure
that
the
circuit
breaker,
storage
expansion
enclosures,
and
storage
server
power
switches
are
in
the
off
position.
4.
Turn
on
the
circuit
breakers
in
the
rack
cabinet,
and
turn
on
the
power
switches
on
all
storage
expansion
enclosures
attached
to
the
DS4400
Storage
Server.
Important:
You
must
turn
on
the
storage
expansion
enclosures
before
the
DS4400
Storage
Server.
The
controllers
might
not
recognize
the
correct
configuration
if
the
attached
drives
are
powered
up
after
the
DS4400
Storage
Server.
For
instructions
on
powering
up
the
storage
expansion
enclosures,
refer
to
the
storage
expansion
enclosure
documentation.
5.
Turn
on
both
power
switches
on
the
back
of
the
DS4400
Storage
Server.
For
the
location
of
the
power
switches,
see
Figure
23
on
page
25.
6.
Check
the
status
of
the
DS4400
Storage
Server
and
other
devices.
Make
sure
all
fault
indicator
lights
are
off
on
the
front
and
back
of
the
DS4400
Storage
Server.
For
more
information,
see
“Checking
the
indicator
lights”
on
page
27.
7.
When
all
the
devices
are
powered
up,
check
the
overall
system
status
using
the
storage-management
software.
Checking
the
battery
service
date
Note:
Replace
the
battery
whenever
it
fails
to
hold
a
charge
or
every
three
years.
Operating
the
DS4400
Storage
Server
in
a
hot
environment
(above
35°
C
or
95°
F)
lowers
the
battery
life
expectancy.
To
check
the
battery
service
date,
do
the
following:
1.
Remove
the
DS4400
Storage
Server
bezel,
as
shown
in
Figure
21
on
page
23.
2.
Check
the
Battery
Support
Information
label,
as
shown
in
Figure
32
on
page
38.
Chapter
2.
Operating
the
DS4400
Storage
Server
37
Содержание TotalStorage DS4400
Страница 1: ...IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide GC26 7730 00...
Страница 2: ......
Страница 3: ...IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide GC26 7730 00...
Страница 7: ...Glossary 75 75 Index 85 Contents v...
Страница 8: ...vi IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Страница 10: ...viii IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Страница 12: ...x IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Страница 18: ...xvi IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Страница 32: ...xxx IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Страница 52: ...20 IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Страница 98: ...66 IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Страница 106: ...74 IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Страница 116: ...84 IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Страница 120: ...88 IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Страница 123: ......
Страница 124: ...Printed in USA GC26 7730 00...