![IBM TotalStorage 3590 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/ibm/totalstorage-3590/totalstorage-3590_operators-manual_4099770047.webp)
Table 5. Operator Messages (continued)
Message
Operator Response
NO MAGAZINE
Operator action required:
The tape subsystem does not detect a magazine in the ACF. If a
magazine is installed in the ACF, clear the condition by removing and
then replacing the magazine in the ACF. Try another or a different
magazine. If the condition persists or a FID message is displayed,
report any FID codes to your service representative.
The operator can use the tape subsystem by loading cartridges into the
priority cell in all modes except in Random mode. Random mode
requires a magazine to be installed and locked.
PICKER
OVERCURRENT
Service representative intervention required.
Report any FID codes to your service representative.
PINCH 1 ERROR
Service representative intervention may be required.
This failure may be caused by a dirty cartridge. Look for any
contamination on the sides of the cartridge that could cause the pinch
rollers to slip. Clean or replace the cartridge.
Note:
Do not ship magazines with cartridges loaded. The cartridges
will vibrate in the magazine slots resulting in contamination on the
sides of the cartridges that may cause this failure.
PINCH 2 ERROR
Service representative intervention may be required.
This failure may be caused by a dirty cartridge. Look for any
contamination on the sides of the cartridge that could cause the pinch
rollers to slip. Clean or replace the cartridge.
Note:
Do not ship magazines with cartridges loaded. The cartridges
will vibrate in the magazine slots resulting in contamination on the
sides of the cartridges that may cause this failure.
PINCH
OVERCURRENT
Service representative intervention required.
Report any FID codes to your service representative.
PRIORITY EXPORT ER
Operator action required:
When the tape subsystem placed a cartridge in the priority cell, the
cartridge was placed either beyond or in front of the Export position.
When the cartridge is not in the Export position, it is possible that a
cartridge placed in front of the Export position may unexpectedly be
reused. When a cartridge is placed beyond the Export position, it is
possible that the cartridge will not be detected in the priority cell.
Correct either of these conditions by removing the cartridge from the
priority cell.
TEMP AC PWR DIP
Operator intervention or possible service representative corrective
action required.
Select Unload on the operator panel and press Enter. If the device fails
to unload the cartridge, note any FID messages and call your service
representative.
Chapter 3. Drive Operator Panel and Controls
27
Содержание TotalStorage 3590
Страница 1: ...IBM TotalStorage Enterprise Tape System 3590 Operator Guide GA32 0330 13 ...
Страница 2: ......
Страница 3: ...IBM TotalStorage Enterprise Tape System 3590 Operator Guide GA32 0330 13 ...
Страница 8: ...vi 3590 Operator Guide ...
Страница 10: ...viii 3590 Operator Guide ...
Страница 20: ...xviii 3590 Operator Guide ...
Страница 92: ...72 3590 Operator Guide ...
Страница 104: ...84 3590 Operator Guide ...
Страница 114: ...94 3590 Operator Guide ...
Страница 118: ...98 3590 Operator Guide ...
Страница 134: ...114 3590 Operator Guide ...
Страница 152: ...132 3590 Operator Guide ...
Страница 165: ......
Страница 167: ...Spine information IBM TotalStorage Enterprise Tape System 3590 3590 Operator Guide ...