Table 7. General specifications (continued)
Specification
Description
Immunity
v
IEC 61000-4-2 Severity Level 3 for
Electrostatic Discharge
v
IEC 61000-4-3 Severity Level 3 for
Radiated Fields
v
IEC 61000-4-4 Severity Level 3 for Fast
Transients
v
IEC 61000-4-5 Severity Level 3 for Surge
Voltage
v
IEC 61000-4-6 Conducted Emissions
v
IEC 61000-4-11 Voltage Variations
Performance specifications
Table 8 lists the performance specifications for the 3534 Model F08.
Table 8. Performance, mechanical, and environmental specifications for the 3534 Model F08
Performance specifications
Routing capacity
A minimum aggregate routing capacity of 10
million frames per second is provided for
Class 2, Class 3 and Class F frames in an
8-port switch.
Latency
The maximum latency for Class 2, Class 3
and Class F frames from input F_port to
output F_port within a single switch is less
than 2 microseconds when the destination
port is free.
Cut-through routing: transmission can begin
as the frame arrives.
Same latency as the 3534 and the 2109
series of switches.
Physical specifications
Table 9 lists the physical specifications for the 3534 Model F08.
Table 9. Physical specifications
Dimension
Value
Enclosure
1U, 48.26 cm (19 in.), EIA
compliant
Height
4.2 cm (1.69 in.)
Depth
26.4 cm (10.4 in.)
Width
42.8 cm (16.9 in.)
Weight
3.9 kg (8.5 lbs)
Appendix A. Product specifications
35
Содержание TotalStorage 3534-F08
Страница 2: ......
Страница 3: ...IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide GC26 7559 00...
Страница 8: ...vi IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...
Страница 10: ...viii IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...
Страница 12: ...x IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...
Страница 18: ...xvi IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...
Страница 22: ...xx IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...
Страница 62: ...40 IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...
Страница 82: ...60 IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...
Страница 94: ...72 IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...
Страница 100: ...78 IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...
Страница 103: ......
Страница 104: ...Part Number 17P7301 Printed in U S A GC26 7559 00 1P P N 17P7301...
Страница 105: ...Spine information IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...