Routing

The embedded processor maintains two routing tables, one for unicast and one for
multicast. The unicast routing tables are constructed during fabric initialization. The
multicast tables are initially empty, except for broadcast. After the tables have been
constructed, they are loaded into each ASIC.

The unicast tables change if ports or links come online or go offline, or if some
other topology changes occur. When new paths become available, the embedded
processor can change some routes in order to share the traffic load. The multicast
tables change as ports register with the alias server to create, join, or leave a
multicast group. Each time a table changes, it must be reloaded into the ASICs.

Service functions

The ASIC interrupts the embedded processor when a frame arrives that has an
error (for example, incorrect source ID), when a frame times out, or when a frame
arrives for a destination that is not in its routing tables. In the latter case, the frame
might be addressed to an illegal destination ID, or it might be addressed to one of
the service functions that the embedded processor provides, such as SNMP, name
server, or alias server.

SNMP

Simple Network Management Protocol (SNMP) allows network devices to be
monitored, controlled, and configured remotely from a network management station
running a network manager program.

SNMP agent code in the network device allows management by transferring data
that is specified by a management information base (MIB).

The 3534 Model F08 agent supports the following functions:

v

SNMPv1 manager

v

Command-line utilities to access and command the agent

v

MIB-II system group, interface group, and SNMP group

v

Fabric-element MIB

v

IBM-specific MIBs

v

Standard generic traps

v

IBM-specific traps

Diagnostics

The 3534 Model F08 supports a set of POSTs, as well as tests that you can run by
using Telnet commands. These diagnostics are used during the manufacturing
process as well as for fault isolation of the product in your installation.

For more information, see the Brocade Diagnostic and System Error Message
Reference
.

Diagnostic environment

Most diagnostics are written to run in the VxWorks environment. However, as
VxWorks does not run without a working SDRAM, a SDRAM/boot EEPROM test is
run as part of the pre-VxWorks startup code to verify that the basic
processor-connected memories are functioning properly.

Chapter 1. Introduction

11

Содержание TotalStorage 3534-F08

Страница 1: ...F08 Installation and User s Guide GC26 7559 00 Read Before Using This product contains software that is licensed under written license agreements Your use of such software is subject to the license ag...

Страница 2: ......

Страница 3: ...IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide GC26 7559 00...

Страница 4: ...es on page xi and Notices on page 55 First Edition May 2003 This edition replaces GC26 7454 01 and SY27 7631 01 Copyright International Business Machines Corporation 2002 2003 All rights reserved US G...

Страница 5: ...ated documents xvii Web sites xviii Getting help xviii Getting software updates xix How to send your comments xix Chapter 1 Introduction 1 Overview of the 3534 Model F08 1 System components 2 Front pa...

Страница 6: ...Replacing an SFP 31 Time required 31 Items required 31 Removing an SFP 31 Installing an SFP 32 Appendix A Product specifications 33 Switch components 33 Facility specifications 33 General specificati...

Страница 7: ...er cables 49 Notices 55 Trademarks 56 Electronic emission notices 56 Federal Communications Commission FCC statement 56 Industry Canada compliance statement 56 Chinese class A compliance statement 57...

Страница 8: ...vi IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Страница 9: ...rting slides into the rack rails 21 11 Front panel LEDs 26 12 Back panel LED 28 13 IBM SFP 31 14 Power cable for Australia 49 15 Power cable for Canada and the United States 50 16 Power cable for Chic...

Страница 10: ...viii IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Страница 11: ...ifications 34 8 Performance mechanical and environmental specifications for the 3534 Model F08 35 9 Physical specifications 35 10 Environmental specifications 36 11 Power supply specifications 36 12 M...

Страница 12: ...x IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Страница 13: ...voltage on metal parts of the system or the products that attach to the system It is the customer s responsibility to ensure that the outlet is correctly wired and grounded to prevent an electrical s...

Страница 14: ...find Checking the safety labels Perform the following safety label checks 1 Verify that the power supply cover caution label shown in Figure 1 is installed on the power supply of the 3534 Model F08 C...

Страница 15: ...n US Components for International Business Machines Corporation Armonk NY This machine is manufactured from new parts or new and used parts Canada ICES NMB 003 Class Classe A P N 18P4393 This device c...

Страница 16: ...ptical connector or with a dust plug Fire suppression systems A fire suppression system is the responsibility of the customer The customer s own insurance underwriter local fire marshal or a local bui...

Страница 17: ...proper handling of the product Contact your IBM representative for more information Product disposal This unit might contain batteries Remove and discard these batteries or recycle them according to...

Страница 18: ...xvi IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Страница 19: ...t help v Instructions on how to get software updates v Information about how to send your comments 3534 Model F08 library The following documents contain information related to this product v IBM Tota...

Страница 20: ...m storage fcswitch For detailed information about fibre channel standards see the fibre channel Association Web site at www fibrechannel com For a directory of worldwide contact information including...

Страница 21: ...s about this document you can submit them in one of the following ways v E mail Submit your comments electronically to starpubs us ibm com Be sure to include the name and order number of the document...

Страница 22: ...xx IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Страница 23: ...factor pluggable media SFP Universal and self configuring Capable of individually becoming a fabric enabled port F_port a fabric loop enabled port FL_port or an expansion port E_port v One serial port...

Страница 24: ...d in groups indicating which ports can be used in the same inter switch link ISL Trunking group Note ISL Trunking enables traffic to be distributed over the combined bandwidth of up to four ISLs betwe...

Страница 25: ...responsible for switch initialization configuration and management Switching functionality is provided by the ASIC The following peripherals are also supported v An Ethernet port v A serial port v Thr...

Страница 26: ...cates with the ASIC and the 10BASE T or 100BASE T Ethernet media access controller MAC through the PCI interface An external PCI bus arbiter enables the Ethernet device to be a bus master You can also...

Страница 27: ...t receives and validates a frame it stores the frame in one of its receive buffers in the central memory and forwards a routing request a Put message to the appropriate destination ports When a destin...

Страница 28: ...trace length The SFP media interfaces with external devices and enables support for shortwave laser and longwave laser Two LEDs for each port provide port status and link speed information Control Mes...

Страница 29: ...no parity no hardware flow control 1 start and 1 stop bit You use this connector to configure the internet protocol IP address and to recover the factory default settings of the switch should Flash me...

Страница 30: ...een indicates 2 Gbps If the green LED is not lit dark it indicates 1 Gbps A single color green LED is located on the front of the switch and indicates system power on status On the back of the switch...

Страница 31: ...ividual switches and ports from a standard workstation For more information see the Brocade Advanced Web Tools User s Guide Auto sensing speed negotiation The 3534 Model F08 ASIC supports link operati...

Страница 32: ...ATM wide area network WAN Note To activate these features go to the following Web site www ibm com storage key Switch initialization When you start or restart the switch the following operations are p...

Страница 33: ...or provides such as SNMP name server or alias server SNMP Simple Network Management Protocol SNMP allows network devices to be monitored controlled and configured remotely from a network management st...

Страница 34: ...device or devices that are attached to the port The 3534 Model F08 has been tested and is compliant with the current FC standards The 3534 Model F08 is compatible with most current generation switches...

Страница 35: ...e switches allows for any Fibre Channel compliant device to attach to the switches as long as it conforms to the standards for device login name service and related Fibre Channel features Regardless o...

Страница 36: ...gement interfaces compatible with the 3534 Model F08 Management interface In band Out of band Command line interface through a Telnet connection X X Web Tools X X Standard simple network management pr...

Страница 37: ...ring the unit with a line to line connection greater than 200 V ac a potential shock hazard can arise during a fault condition Therefore double pole protection is required 5 v Ensure the ambient air t...

Страница 38: ...an ac switch The 3534 Model F08 automatically runs a POST each time power is supplied to it DANGER An electrical outlet that is not correctly wired could place a hazardous voltage on metal parts of t...

Страница 39: ...ck mount installation procedure consists of the following four steps 1 Mount the moving slide and the lock mounting ears to the switch 2 Mount the fixed portion of the slide in the rack 3 Insert the s...

Страница 40: ...2b for the other rail Note For racks with flush mount doors such as the 9306 Netfinity racks you can eliminate the installation of the ears Instead use the rack mount slides by attaching the 3534 Mode...

Страница 41: ...s in the bracket align with the two threaded holes in the switch chassis b Attach the bracket using two of the 8 32 x 3 16 in zinc screws 6 Attention Using screws longer than 3 16 in can damage the sw...

Страница 42: ...9 a At the desired height install the five M5 nut clips 5 put three in the front of the rack and two in the back The middle clip in the front of the rack is for the locking ears b Attach the slides u...

Страница 43: ...o supply power to the switch connect the power cable to the 3534 Model F08 power supply and to a power outlet The power supply does not have an ac switch The 3534 Model F08 automatically runs a POST e...

Страница 44: ...RS 232 serial port is available on the workstation you can remove the adapter that is on the end of the serial cable This enables you to use the RJ 45 connector to create a serial connection 3 Verify...

Страница 45: ...t connection or through a network and to access the switch 1 Remove the shipping plug from the Ethernet port 2 Insert one end of an Ethernet cable in the Ethernet port 3 Connect the other end of the E...

Страница 46: ...akes a clicking sound Note The SFP is keyed so that it can only be correctly inserted into the port If the module does not slide in easily try turning it over Do not force the module c Connect the fib...

Страница 47: ...green orange or yellow during a POST This is normal This does not indicate that there is a problem unless the LEDs do not return to a normal pattern after the POST is complete The 3534 Model F08 has...

Страница 48: ...ht Either the switch is off the startup process is not complete or the startup has failed Verify that the switch has power and that the startup process has had time to complete If there is still no li...

Страница 49: ...low flashing orange on 1 second off 1 second The port is disabled as a result of diagnostics or a portDisable command Reset the port from a management station Fast flashing orange on 1 4 second off 1...

Страница 50: ...ly completed No action is required Steady yellow A diagnostic test is in progress or one or more ports are faulty If no diagnostic tests are running check the Port Status LEDs for fault indicators see...

Страница 51: ...rify that the flashing is not due to the switch being configured to beacon Note The switchBeacon command sets the switch beaconing mode on or off if the operand is 1 or 0 respectively When beaconing m...

Страница 52: ...of 1 Gbps and 2 Gbps As a result the transmit and receive speed of the links can be temporarily locked at one speed or the other while the diagnostic tests are running For information about the specif...

Страница 53: ...o unplug the switch to replace an SFP Figure 13 shows an IBM SFP Time required Approximately 20 seconds to remove and install an SFP Items required None Note This operation is hands only Removing an S...

Страница 54: ...appropriate port slot The latch prong locks and prevents the SFP from being removed accidentally Note The SFP is keyed so that it can only be correctly inserted into the port If the module does not s...

Страница 55: ...LED on the front panel to indicate the overall switch status Two LEDs for each of the eight ports to indicate port status and link speed Two LEDs for the Ethernet port to indicate port status and lin...

Страница 56: ...el F08 that conforms to the EMI radiation levels specified by the following regulations v FCC Rules and Regulations Part 15B Class A level v CISPR22 Class A v EN55022 Class A v VCCI Class A ITE v AS N...

Страница 57: ...ns Routing capacity A minimum aggregate routing capacity of 10 million frames per second is provided for Class 2 Class 3 and Class F frames in an 8 port switch Latency The maximum latency for Class 2...

Страница 58: ...ower consumption 50 W maximum Power supply specifications The 3534 Model F08 has a universal power supply that is capable of functioning worldwide without voltage jumpers or switches The power supply...

Страница 59: ...rds For details see Regulatory specifications on page 38 Serial port specifications The serial port is on the front panel of the switch and uses an RS 232 connector Note For dust and electrostatic dis...

Страница 60: ...22 Class A Norway Nemko IEC 60950 A1 A2 A3 A4 A11 CB Report European Union Austria Belgium Denmark Finland France Germany Greece Ireland Italy Luxembourg Netherlands Portugal Spain Sweden United Kingd...

Страница 61: ...e 14 Regulatory specifications continued Country or region Safety specification EMC specification Australia and New Zealand AS NZS 3548 1995 Class A radio interference Appendix A Product specification...

Страница 62: ...40 IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Страница 63: ...or later FC IP v SCSI Enclosure Services Rev 8a v EA TIA RS 232 Serial Port specification v Gigabit Interface Converter Definition Document Sun and so on v IEEE 802 3 for Ethernet Protocol compliance...

Страница 64: ...hm to minimize the impact of the route recalculation To minimize disruption the switch only reroutes traffic due to a new shortest path if one has been established or if new load sharing is required F...

Страница 65: ...Taiwan v C tick mark Australia v CE Mark Europe v Canada class number v GOST approval Russia v NOM mark Mexico EMI EMC Radiated Electro Magnetic Interference EMI emissions for the 3534 Model F08 power...

Страница 66: ...llowing specifications v EN 61000 4 2 Severity Level 3 for ESD v EN 61000 4 3 Severity Level 3 for RF Fields v EN 61000 4 4 Severity Level 3 for EFT Burst v EN 61000 4 5 Severity Level 3 for Surge Vol...

Страница 67: ...lation of your switches Give your system administrator copies of the completed worksheets Planning worksheet Table 15 Planning worksheet Item Description Firmware level Firmware location Server name U...

Страница 68: ...worksheet Table 16 Port configuration worksheet Port number Device name Device port Cable length Port type Notes Cable number 0 1 2 3 4 5 6 7 46 IBM TotalStorage SAN Switch 3534 Model F08 Installatio...

Страница 69: ...ksheet Table 17 Zone definition worksheet Zone member type switch port WWN Zone member Zone configuration name Comments Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Appendix D Blank pla...

Страница 70: ...e switch port WWN Zone member Zone configuration name Connects to Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port...

Страница 71: ...6952301 1 83 m 6 ft 250 V 10A China 9840 02K0546 2 74 m 9 ft 250 V 6A Denmark 9821 13F9997 2 74 m 9 ft 250 V 10A France 9820 13F9979 2 74 m 9 ft 250 V 10A Israel 9827 14F0087 2 74 m 9 ft 250 V 10A It...

Страница 72: ...Figure 15 Power cable for Canada and the United States Figure 16 Power cable for Chicago Figure 17 Power cable for China 50 IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Страница 73: ...Figure 18 Power cable for Denmark Figure 19 Power cable for France Figure 20 Power cable for Israel Appendix E Power cables 51...

Страница 74: ...Figure 21 Power cable for Italy Figure 22 Power cable for South Africa Figure 23 Power cable for Switzerland 52 IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Страница 75: ...Figure 24 Power cable for Thailand Figure 25 Power cable for United Kingdom Figure 26 Power cable for Uruguay Appendix E Power cables 53...

Страница 76: ...Figure 27 PDU cable that is shipped with the 3534 Model F08 54 IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Страница 77: ...R IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranti...

Страница 78: ...ses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in...

Страница 79: ...n a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures The standards compliance label on the 3534 Model F08 contains the CE...

Страница 80: ...elekommunikation oder des Bundesamtes fuer Post und Telekommunikation betrieben werden Die Genehmigung wird erteilt wenn keine elektromagnetischen Stoerungen zu erwarten sind Auszug aus dem EMVG Parag...

Страница 81: ...note that this device has been approved for business purposes with regard to electromagnetic interference If you find that this is not suitable for your use you may exchange it for one with a non busi...

Страница 82: ...60 IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Страница 83: ...address to an address used by a supporting metropolitan or local area network such as Ethernet or token ring alias address identifier One or more address identifiers which can be recognized by a node...

Страница 84: ...aneous transmission of the same data to all nodes connected to a network 2 The simultaneous transmission of data to more than one destination See also multicast and unicast BTU See British thermal uni...

Страница 85: ...s and zeros positive disparity indicates a majority of ones and negative disparity indicates a majority of zeros DLS See dynamic load sharing DMA See direct memory access domain_ID A unique identifier...

Страница 86: ...also fabric loop port and Fx_port Fabric Watch A feature that runs on the Fabric operating system OS and allows monitoring and configuration of fabric and switch elements FC See Fibre channel FC AL S...

Страница 87: ...ic port F_port or as an expansion port E_port The functionality of a G_port is determined during port login A G_port functions as an F_port when connected to a node port N_port and as an E_port when c...

Страница 88: ...xpansion port IU See information unit K28 5 A special 10 bit character used to indicate the beginning of a transmission word that performs Fibre channel control and signaling functions The first seven...

Страница 89: ...fabric Some implementations can function either as N_ports or as NL_ports depending on the network to which they are connected An NL_port must replicate frames and pass then on when in passive loop mo...

Страница 90: ...ublic NL_ports QuickLoop 1 A feature that makes it possible to allow private devices within loops to communicate with public and private devices across the fabric through the creation of a larger loop...

Страница 91: ...k management protocol SNMP In the Internet suite of protocols a network management protocol that is used to monitor routers and attached networks SMNP is an application layer protocol Information on d...

Страница 92: ...a specific function in the fabric U_port See universal port upper layer protocol ULP A protocol used on a Fibre Channel network at or above the FC 4 level upper layer timeout value ULP_TOV The minimum...

Страница 93: ...nging to the same zone configuration When a zone configuration is in effect all valid zones in that configuration are also in effect zoning In Fibre Channel environments the grouping of multiple ports...

Страница 94: ...72 IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Страница 95: ...how to send xix compliance protocol 41 regulatory 43 standards 41 compliance statements Chinese class A 57 European Community 57 Federal Communications Commission FCC 56 Germany 58 Industry Canada 56...

Страница 96: ...nt panel of switch description 2 LEDs 2 25 functions service 11 G general specifications of the switch 34 Germany compliance statement 58 getting help xviii software updates xix H hardware components...

Страница 97: ...ical port port information 7 specifications 37 terminators xiv out of band management method 14 outlet danger notice xiii 16 21 overview of the 3534 Model F08 1 P package switch 1 panel LEDs back 28 f...

Страница 98: ...8 speed LEDs Ethernet 25 speed LEDs continued port 25 27 speed negotiation auto sensing 9 stand alone unit installing the switch as 16 standards compliance 41 statements Chinese class A compliance 57...

Страница 99: ...ack program IBM products xiv temperature ambient air 15 terminators for optical ports xiv trademarks 56 translations of safety notices xi trunking 9 turning the switch on and off 25 U unauthorized cha...

Страница 100: ...78 IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Страница 101: ...n this book is Very Satisfied Satisfied Neutral Dissatisfied Very Dissatisfied Accurate h h h h h Complete h h h h h Easy to find h h h h h Easy to understand h h h h h Well organized h h h h h Applic...

Страница 102: ...artment Dept M86 Bldg 050 3 5600 Cottle Road San Jose CA 95193 0001 U S A _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 103: ......

Страница 104: ...Part Number 17P7301 Printed in U S A GC26 7559 00 1P P N 17P7301...

Страница 105: ...Spine information IBM TotalStorage SAN Switch 3534 Model F08 Installation and User s Guide...

Отзывы: