code
Description
Action
166-060-000
System
Management:
Failed.
Unable
to
communicate
with
ASM.
It
may
be
busy.
Run
the
test
again.
1.
Update
the
firmware
(BIOS,
service
processor,
and
diagnostics;
see
2.
Run
the
diagnostic
test
again.
3.
Correct
other
error
conditions
(including
failed
systems-management
tests
and
items
that
are
logged
in
the
Remote
Supervisor
Adapter
II
SlimLine
system-error
log)
and
retry.
4.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
5.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine.
6.
Replace
the
Remote
Supervisor
Adapter
II
SlimLine.
166-070-000
System
Management:
Failed.
Unable
to
communicate
with
ASM.
It
may
be
busy.
Run
the
test
again.
1.
Update
the
firmware
(BIOS,
service
processor,
and
diagnostics;
see
2.
Run
the
diagnostic
test
again.
3.
Correct
other
error
conditions
(including
failed
systems-management
tests
and
items
that
are
logged
in
the
Remote
Supervisor
Adapter
II
SlimLine
system-error
log)
and
retry.
4.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
5.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine.
6.
Replace
the
Remote
Supervisor
Adapter
II
SlimLine.
166-198-000
BIOS
cannot
detect
ASM.
Reseat
ASM
adapter
in
correct
slot;
ASM
restart
failure.
Unplug
and
cold
boot
server
to
reset
ASM.
1.
Run
the
diagnostic
test
again.
2.
Correct
other
error
conditions
(including
other
failed
systems-management
tests
and
items
that
are
logged
in
the
Remote
Supervisor
Adapter
II
SlimLine
system-error
log)
and
retry.
3.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
4.
Reseat
the
following
components:
a.
Remote
Supervisor
Adapter
II
SlimLine
b.
I/O
board
5.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
70
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide
Содержание System x3950
Страница 1: ...IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 124: ...108 IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 132: ...116 IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 176: ...160 IBM System x3950 Type 8878 and System x3950 E Type 8879 Problem Determination and Service Guide...
Страница 189: ......
Страница 190: ...Part Number 31R1886 Printed in USA 1P P N 31R1886...