Superior performance/U in a 4-socket, 2U server

 

Please see the Legal Information section for important notices and information. 

  Hot-swap, redundant 

power supplies

 (optional)—Energy Star-compliant (80+Gold); up to 

92%

 efficient 

  Hot-swap, redundant 

cooling fans

 

 

Light Path Diagnostics 

Light path diagnostics enables a technician to quickly identify and locate a failed or failing system 
component, such as a specific fan or memory DIMM. This enables quick replacement of the 
component, which helps increase server uptime and lower operating costs.  

The front of the server has an LED indicator light to show possible component failures. If the front 
LED indicates an error condition, by pressing a button on the front of the server an LED panel will 
pop out and drop down for easy viewing without the need to open the server cover or remove the 
server from the rack. The light path diagnostics panel tells the servicer which component requires 
attention. In addition, many components have their own identifying LEDs. For example, each of 
the memory modules has an LED next to the DIMM slot, as do all processors, all adapter slots, all 
fans, the power supply, the voltage regulator modules and the service processor. This allows the 
servicer to easily identify exactly which component needs servicing. By following the “light path,” 
the component can be replaced quickly, and without guesswork. (

Note:

 In the event of a failed 

DIMM or processor, the system will restart and mark the component as bad while offline, thus 
allowing the system to continue running, with reduced capacity, until serviced.)

 

 

Other Features 

 

Trusted Platform Module standard 

— This module provides a highly secure start-up process 

from power-on through hand-off to the operating system boot loader. ACPI support is provided 
to allow ACPI-enabled operating systems to access the security features of this module. (TCG 
V1.2-compliant.) 

 

Five USB 2.0 ports

 — Provides flexibility to add high-speed external devices. The USB 2.0 

specification supports up to 480Mbps transfer rates. (Note: Not all USB 2.0 devices are 
capable of achieving this rate.) 

Two

 ports are provided on the front of the server, 

two

 are on 

the back, and 

1

 is internal to support an optional flash memory key

 

with

 

embedded hypervisor. 

 

Toolless slides

 — Allows quick rack installation and quicker upgrade and servicing of the 

server. 

 

Toolless chassis 

— The cover can be opened without tools, and many components can be 

added or replaced without tools, including processors, DIMMs, hot-swap HDDs, PCIe 
adapters, an optional optical drive, and the integrated or optional ServeRAID controller. This 
can save a servicer significant time.  

 

Advanced Systems Management Capabilities 

The x3755 M3 has a high level of systems management capabilities that are well-suited to 
remote locations as well as to stand-alone environments. Features include the UEFI, an 
integrated Baseboard Management Controller (iBMC) with remote presence, IBM ToolsCenter, IBM 
Systems Director Active Energy Manager, Automatic Server Restart, Wake on LAN support, PXE 
support, text console redirect, Predictive Failure Analysis, and IBM Systems Director. 

The iBMC provides industry-standard 

Intelligent Platform Management Interface

 (

IPMI

2.0

-

compliant systems management. It provides a number of important system functions, including: 

  Monitoring of system and battery voltage, system temperature, fans, power supplies, 

processor and DIMM status 

  Fan speed control 

  Product ID and Family ID detection 

  Highly secure remote power on/off 

  System reset control 

  NMI/SMI detection and generation 

  System diagnostic LED control (power, HDD, activity, alerts, heartbeat) 

  IPMI over LAN 

  Serial Over LAN 

  Proxy server support 

  LAN messaging and alerting 

  Text console redirection over LAN 

  Predictive Failure Analysis for system fans 

  Web-based out-of-band control 

Содержание System x3755 M3 7164

Страница 1: ...adapter slots All models offer support for two or four processors and a choice of high performance hard disk drives with an internal storage capacity of up to 16TB eight 3 5 inch hot swap SATA drives or 4 8TB 2 four 3 5 inch hot swap SAS drives The integrated ServeRAID SAS Serial Attach SCSI SATA Serial attach ATA controller provides hardware based RAID 0 1 10 or RAID 0 1 10 5 50 support standard ...

Страница 2: ...aw Up to 256GB of high speed DDR3 system memory 64GB per processor Three available high performance adapter slots one PCIe x16 one x8 one x4 in all models Hardware based support for RAID 0 1 10 upgradeable to RAID 5 50 is provided standard in most models Other models provide RAID 0 1 10 5 50 standard upgradeable with RAID 6 60 and battery backup The five USB 2 0 ports are up to 40X faster 3 than o...

Страница 3: ...ut having to visit it in person saving travel time and getting the server back up and running quickly and securely It also adds new features to those provided by IPMI 1 5 including VLAN support Serial over LAN enhanced authentication and encryption algorithms RMCP and AES and a firmware firewall Temperature controlled hot swap redundant fans adjust to compensate for changing thermal characteristic...

Страница 4: ... buffered memory Now a generation later DDR3 memory is even more efficient using 10 15 less energy than DDR2 memory The x3755 M3 supports up to 32 DIMMs with 8 DIMM slots assigned to each processor four memory channels with two DIMM slots and one memory controller per channel Therefore a 2 processor system is limited to 16 DIMMs Four processors are required to use all 32 DIMM slots Memory types su...

Страница 5: ...s are available for added throughput and increased system availability Ultra Efficient Cooling Strategically located fans combined with efficient airflow paths provide highly effective system cooling for the x3755 M3 The server includes five hot swap fans standard These offer failover capability In addition each power supply contains a fan The system contains two cooling zones Zone 1 incorporating...

Страница 6: ... operating systems to access the security features of this module TCG V1 2 compliant Five USB 2 0 ports Provides flexibility to add high speed external devices The USB 2 0 specification supports up to 480Mbps transfer rates Note Not all USB 2 0 devices are capable of achieving this rate Two ports are provided on the front of the server two are on the back and 1 is internal to support an optional f...

Страница 7: ...remotely that would otherwise require a visit to each system These tasks may include such things as formatting a hard disk drive updating system firmware or deploying a Windows or Linux operating system Text and Graphical Console Redirection support allows the administrator to remotely view system text messages and graphics over serial or LAN Predictive Failure Analysis PFA is designed to allow th...

Страница 8: ...th fast 1333MHz memory access reduces memory latency and facilitates the movement of data through the processor and I O devices Note System performance depends not only on the number of processors in the server but also on the power and functionality of each processor Adding additional processors may be a cost effective way to achieve significant performance improvements Memory Memory is a signifi...

Страница 9: ...rly the IBM ServeRAID M5000 Series Advance Feature Key adds RAID 6 60 support to the M5015 x3755 M3 Images Front View Rear View PCIe Slots Video Port HS Redundant Power Supplies USB Ports Serial Port 10 100 Ethernet Port for BMC Gb Ethernet Ports Hexagonal Ventilation Holes Status LEDs USB Ports 8 Hot Swap SAS SATA Bays Pop Out Light Path Diagnostics Panel Optional Optical Drive Light Path Diagnos...

Страница 10: ...rage 22x 42x 62x 79W 65W average 6124HE via CTO Maximum power draw per core 14 4W 22x 42x 11 4W 6176SE 9 9W 6124HE 9 6W 62x HyperTransport link speed 3 2GHz coherent among processors 2 6GHz noncoherent between processors and I O of processors standard maximum 2 4 22x 42x 62x Internal L2 L3 processor cache 512B L2 per core 12MB L3 shared by all cores Chipset AMD SR5690 and SP5100 Standard memory5 1...

Страница 11: ...ndard None of optical drives standard None of diskette drives standard None optional external USB Internal tape drives supported No Disk drive technology Hot swap SAS SATA Integrated disk controller 8 port SAS RAID of disk drives supported per port 1 External disk drives supported Yes via adapter Integrated RAID controller standard ServeRAID M1015 x8 PCIe no cache RAID 0 1 10 optional RAID 5 22x 4...

Страница 12: ...Cable Management Arm provided standard Maximum altitude 7 000 ft 2 133 m Operating temperature range 50 95º F 10 35º C up to 3 000 ft 914 4 m 50 90º F 10 32º C 3 000 ft to 7 000 ft 914 4m to 2 133m Dimensions HWD weight 3 43 87mm H 17 56 446mm W 28 64 727 5mm D without front panel 29 4 747mm D with front panel 48 6 minimum 72 7 lb maximum 22 33 kg Operating systems supported Microsoft Windows Serv...

Страница 13: ...t two rear one internal for a hypervisor or tape drive Optional high performance RAID controllers Four available adapter slots One x16 x16 7 PCIe Gen 2 slot 16GBps Two x8 x8 8 PCIe Gen 2 slot 8GBps One x8 x4 9 PCIe Gen 2 slots 4GBps Optional integrated optical drive Manageability Serviceability and Availability IBM Systems Director systems management software including among others IBM Systems Dir...

Страница 14: ... Modeling Simulation 2 1 1 1 3 1 3 2 3 3 High Performance DB 2 2 1 1 1 3 2 2 3 3 Business Intelligence 2 1 1 1 2 1 2 2 1 3 Search 3 1 1 1 2 1 3 3 1 2 Content 2 2 2 2 2 1 3 3 2 2 Communities 1 2 2 2 1 1 2 3 2 2 Commerce 2 1 1 1 2 1 1 2 1 2 Collaboration 2 3 2 3 2 1 2 3 2 2 ERP SCM 1 2 1 1 1 2 1 1 1 2 CRM 2 2 2 2 2 2 2 2 1 3 Best Hosted Client 1 3 2 1 2 2 1 1 2 2 Point of Sale 3 3 3 2 1 3 1 1 1 1 Br...

Страница 15: ...s or services do not imply that IBM intends to make them available in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions therefore this...

Отзывы: