background image

Superior performance/U in a 4-socket, 2U server

 

Please see the Legal Information section for important notices and information. 

15 

 

 

 

 

For More Information 

IBM System x Servers and Options 

 

 

       

http://

ibm.com

/systems/x

  

IBM Standalone Solutions Configuration Tool 

 

       

http://

ibm.com

/systems/x/hardware/configtools.html  

IBM Configuration and Options Guide    

 

      

 http://

ibm.com

/systems/x/hardware/configtools.html   

IBM ServerProven Program 

 

 

 

       

http://

ibm.com

/systems/info/x86servers/serverproven/compat/us

  

Technical Support 

 

 

 

       

http://

ibm.com

/server/support  

Other Technical Support Resources 

 

 

       

http://

ibm.com

/systems/support

 

Legal Information 

© IBM Corporation 2010 

IBM Systems and Technology Group 
Dept. U2SA 
3039 Cornwallis Road 
Research Triangle Park, NC 27709 

Produced in the USA 
August 2010 
All rights reserved 

For a copy of applicable product warranties, write to: Warranty 
Information, P.O. Box 12195, RTP, NC 27709, Attn: Dept. 
JDJA/B203. IBM makes no representation or warranty 
regarding third-party products or services including those 
designated as ServerProven or ClusterProven

®

. Telephone 

support may be subject to additional charges. For onsite labor, 
IBM will attempt to diagnose and resolve the problem remotely 
before sending a technician. 

IBM, the IBM logo, ibm.com, Active Energy Manager, Active 
Memory, Chipkill, ClusterProven, ServeRAID, ServerGuide, 
ServerProven, System Storage, System x, Wake on LAN, and 
X-Architecture are trademarks of IBM Corporation in the 
United States, other countries, or both. If these and other IBM 
trademarked terms are marked on their first occurrence in this 
information with a trademark symbol (

®

 or ™), these symbols 

indicate U.S. registered or common law trademarks owned by 
IBM at the time this information was published. Such 
trademarks may also be registered or common law 
trademarks in other countries. A current list of IBM trademarks 
is available on the Web at 

http://

ibm.com

/legal/copytrade.shtml

Linux is a registered trademark of Linus Torvalds. 

Microsoft, Windows, and the Windows logo are trademarks or 
registered trademarks of Microsoft Corporation. 

Other company, product and service names may be 
trademarks or service marks of others. 

IBM reserves the right to change specifications or other 
product information without notice. References in this 
publication to IBM products or services do not imply that IBM 
intends to make them available in all countries in which IBM 
operates. IBM PROVIDES THIS PUBLICATION “AS IS” 
WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS  

OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR 
PURPOSE. Some jurisdictions do not allow disclaimer of 
express or implied warranties in certain transactions; 
therefore, this statement may not apply to you. 

This publication may contain links to third party sites that are 
not under the control of or maintained by IBM. Access to any 
such third party site is at the user's own risk and IBM is not 
responsible for the accuracy or reliability of any information, 
data, opinions, advice or statements made on these sites. IBM 
provides these links merely as a convenience and the 
inclusion of such links does not imply an endorsement. 

Information in this presentation concerning non-IBM products 
was obtained from the suppliers of these products, published 
announcement material or other publicly available sources. 
IBM has not tested these products and cannot confirm the 
accuracy of performance, compatibility or any other claims 
related to non-IBM products. Questions on the capabilities of 
non-IBM products should be addressed to the suppliers of 
those products. 

MB, GB and TB = 1,000,000, 1,000,000,000 and 
1,000,000,000,000 bytes, respectively, when referring to 
storage capacity. Accessible capacity is less; up to 3GB is 
used in service partition. Actual storage capacity will vary 
based upon many factors and may be less than stated. 

Performance is in Internal Throughput Rate (ITR) ratio based 
on measurements and projections using standard IBM 
benchmarks in a controlled environment. The actual 
throughput that any user will experience will depend on 
considerations such as the amount of multiprogramming in the 
user’s job stream, the I/O configuration, the storage 
configuration and the workload processed. Therefore, no 
assurance can be given that an individual user will achieve 
throughput improvements equivalent to the performance ratios 
stated here. 

Maximum internal hard disk and memory capacities may 
require the replacement of any standard hard drives and/or 
memory and the population of all hard disk bays and memory 
slots with the largest currently supported drives available. 
When referring to variable speed CD-ROMs, CD-Rs, CD-RWs 
and DVDs, actual playback speed will vary and is often less 
than the maximum possible.

 

          XSO03119-USEN-00 

Содержание System x3755 M3 7164

Страница 1: ...adapter slots All models offer support for two or four processors and a choice of high performance hard disk drives with an internal storage capacity of up to 16TB eight 3 5 inch hot swap SATA drives or 4 8TB 2 four 3 5 inch hot swap SAS drives The integrated ServeRAID SAS Serial Attach SCSI SATA Serial attach ATA controller provides hardware based RAID 0 1 10 or RAID 0 1 10 5 50 support standard ...

Страница 2: ...aw Up to 256GB of high speed DDR3 system memory 64GB per processor Three available high performance adapter slots one PCIe x16 one x8 one x4 in all models Hardware based support for RAID 0 1 10 upgradeable to RAID 5 50 is provided standard in most models Other models provide RAID 0 1 10 5 50 standard upgradeable with RAID 6 60 and battery backup The five USB 2 0 ports are up to 40X faster 3 than o...

Страница 3: ...ut having to visit it in person saving travel time and getting the server back up and running quickly and securely It also adds new features to those provided by IPMI 1 5 including VLAN support Serial over LAN enhanced authentication and encryption algorithms RMCP and AES and a firmware firewall Temperature controlled hot swap redundant fans adjust to compensate for changing thermal characteristic...

Страница 4: ... buffered memory Now a generation later DDR3 memory is even more efficient using 10 15 less energy than DDR2 memory The x3755 M3 supports up to 32 DIMMs with 8 DIMM slots assigned to each processor four memory channels with two DIMM slots and one memory controller per channel Therefore a 2 processor system is limited to 16 DIMMs Four processors are required to use all 32 DIMM slots Memory types su...

Страница 5: ...s are available for added throughput and increased system availability Ultra Efficient Cooling Strategically located fans combined with efficient airflow paths provide highly effective system cooling for the x3755 M3 The server includes five hot swap fans standard These offer failover capability In addition each power supply contains a fan The system contains two cooling zones Zone 1 incorporating...

Страница 6: ... operating systems to access the security features of this module TCG V1 2 compliant Five USB 2 0 ports Provides flexibility to add high speed external devices The USB 2 0 specification supports up to 480Mbps transfer rates Note Not all USB 2 0 devices are capable of achieving this rate Two ports are provided on the front of the server two are on the back and 1 is internal to support an optional f...

Страница 7: ...remotely that would otherwise require a visit to each system These tasks may include such things as formatting a hard disk drive updating system firmware or deploying a Windows or Linux operating system Text and Graphical Console Redirection support allows the administrator to remotely view system text messages and graphics over serial or LAN Predictive Failure Analysis PFA is designed to allow th...

Страница 8: ...th fast 1333MHz memory access reduces memory latency and facilitates the movement of data through the processor and I O devices Note System performance depends not only on the number of processors in the server but also on the power and functionality of each processor Adding additional processors may be a cost effective way to achieve significant performance improvements Memory Memory is a signifi...

Страница 9: ...rly the IBM ServeRAID M5000 Series Advance Feature Key adds RAID 6 60 support to the M5015 x3755 M3 Images Front View Rear View PCIe Slots Video Port HS Redundant Power Supplies USB Ports Serial Port 10 100 Ethernet Port for BMC Gb Ethernet Ports Hexagonal Ventilation Holes Status LEDs USB Ports 8 Hot Swap SAS SATA Bays Pop Out Light Path Diagnostics Panel Optional Optical Drive Light Path Diagnos...

Страница 10: ...rage 22x 42x 62x 79W 65W average 6124HE via CTO Maximum power draw per core 14 4W 22x 42x 11 4W 6176SE 9 9W 6124HE 9 6W 62x HyperTransport link speed 3 2GHz coherent among processors 2 6GHz noncoherent between processors and I O of processors standard maximum 2 4 22x 42x 62x Internal L2 L3 processor cache 512B L2 per core 12MB L3 shared by all cores Chipset AMD SR5690 and SP5100 Standard memory5 1...

Страница 11: ...ndard None of optical drives standard None of diskette drives standard None optional external USB Internal tape drives supported No Disk drive technology Hot swap SAS SATA Integrated disk controller 8 port SAS RAID of disk drives supported per port 1 External disk drives supported Yes via adapter Integrated RAID controller standard ServeRAID M1015 x8 PCIe no cache RAID 0 1 10 optional RAID 5 22x 4...

Страница 12: ...Cable Management Arm provided standard Maximum altitude 7 000 ft 2 133 m Operating temperature range 50 95º F 10 35º C up to 3 000 ft 914 4 m 50 90º F 10 32º C 3 000 ft to 7 000 ft 914 4m to 2 133m Dimensions HWD weight 3 43 87mm H 17 56 446mm W 28 64 727 5mm D without front panel 29 4 747mm D with front panel 48 6 minimum 72 7 lb maximum 22 33 kg Operating systems supported Microsoft Windows Serv...

Страница 13: ...t two rear one internal for a hypervisor or tape drive Optional high performance RAID controllers Four available adapter slots One x16 x16 7 PCIe Gen 2 slot 16GBps Two x8 x8 8 PCIe Gen 2 slot 8GBps One x8 x4 9 PCIe Gen 2 slots 4GBps Optional integrated optical drive Manageability Serviceability and Availability IBM Systems Director systems management software including among others IBM Systems Dir...

Страница 14: ... Modeling Simulation 2 1 1 1 3 1 3 2 3 3 High Performance DB 2 2 1 1 1 3 2 2 3 3 Business Intelligence 2 1 1 1 2 1 2 2 1 3 Search 3 1 1 1 2 1 3 3 1 2 Content 2 2 2 2 2 1 3 3 2 2 Communities 1 2 2 2 1 1 2 3 2 2 Commerce 2 1 1 1 2 1 1 2 1 2 Collaboration 2 3 2 3 2 1 2 3 2 2 ERP SCM 1 2 1 1 1 2 1 1 1 2 CRM 2 2 2 2 2 2 2 2 1 3 Best Hosted Client 1 3 2 1 2 2 1 1 2 2 Point of Sale 3 3 3 2 1 3 1 1 1 1 Br...

Страница 15: ...s or services do not imply that IBM intends to make them available in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions therefore this...

Отзывы: