A cost-optimized storage-rich alternative to traditional enterprise 2U dual-socket servers

 

Please see the Legal Information section for important notices and information. 

 

High-Performance Adapter Slots 

The x3620 M3 provides 

three

 

PCIe

 (PCI Express) 

Gen 2

 I/O slots for long-term investment 

protection. 

PCI Express

 Gen 2 is the next-generation of high-performance, low-latency, serial I/O 

bus. Each slot is capable of supporting Gen 1 or Gen 2 adapters.

 

 

  One 

x16/x8 

(x16 physical/x8 electrical)

 full-

height,

 half-

length (

8Gbps

  One 

x8/x8 

(x8 physical/x8 electrical)

 full-

height,

 half-

length (

8Gbps

  One 

x16/x4 

(x16 physical/x4 electrical)

 low profile

 (

4Gbps

) — for ServeRAID cards, only 

 

Dual-Port Gigabit Ethernet Controller 

The x3620 M3 includes 

one dual-port

 integrated 

Intel 82575 

Gigabit Ethernet controller 

standard, for up to 10X higher maximum throughput than a 10/100 Ethernet controller and 
failover support. 

The controller also supports 

IPMI

 

2.0

, plus 

Wake on LAN

®

 and 

PXE

 (Preboot Execution 

Environment) flash interface. Optional PCI adapters offering failover and load balancing between 
adapters are available for added throughput and increased system availability. 

 

10 Gigabit Ethernet Integrated Virtual Fabric Adapter for IBM 

The Emulex Virtual Fabric Adapter (part number 49Y4200 with special riser card, supported by 
CTO) is an industry-leading performance and scalability per watt, dual-port network adapter for 
10Gbps Ethernet (10GbE) networks. It offers the benefits and flexibility of I/O convergence in a 
single end-to-end solution. Protocol offload for stateless TCP/IP and TCP Chimney provide 
maximum bandwidth with minimum use of CPU resources. It achieves line rate 10Gbps 
performance with support for TCP/IP stateless offloads and TCP Offload Engine (TOE) support. 
TOE reduces system processor utilization, providing increased system performance and reducing 
overall system power requirements. 

The adapter is based on the Emulex OneConnect Universal Converged Network Adapter (UCNA) 
platform that also includes the capability for future upgrades to Fibre Channel over Ethernet 
(FCoE) and iSCSI protocol offloads. By using a common infrastructure for Ethernet and storage 
networks, data centers can reduce capital expense (CapEx) for adapters, switches and cables, 
and operational expense (OpEx) for power, cooling and IT administration.

 

End-to-end data protection with hardware parity, CRC, ECC and other advanced error checking 
and correcting ensure that data is safe from corruption. 

Integrated dual 10Gbps Ethernet ports: 

  IPv4/IPv6 TCP, UDP checksum offload; Large Send Offload (LSO); Large Receive Offload; 

Receive Side Scaling (RSS); IPV4 TCP Chimney Offload 

  VLAN insertion and extraction 

  Jumbo frames up to 9000 Bytes 

  Preboot eXecutive Environment (PXE) 2.0 network boot support 

  Interrupt coalescing 

  Load balancing and failover support including adapter fault tolerance (AFT), switch fault 

tolerance (SFT), adaptive load balancing (ALB), teaming support and IEEE 802.3ad 

Note

: You must have either one SFP+ transceiver or one SFP+ direct-attached cable for 

each

 of 

the two 10Gb ports on the adapter.

 

 

 

Ultra-Efficient Cooling 

Strategically located fans, combined with efficient airflow paths, provide highly effective system 
cooling for the x3620 M3. The base server with one power supply includes 

four

 fan modules, for 

redundant cooling. Each module includes 

2

 back-to-back fans with counter-rotating blades. In 

addition, each power supply also contains a fan. 

The system contains 

two cooling zones

Zone 1

 (incorporating one fan module) cools the PCIe 

slots, 

Zone 2

 (three fan modules) cools both processors and all the DIMMs. 

The fans automatically adjust speeds in response to changing thermal requirements depending 
on the zone and internal temperatures. When the temperature inside the server increases, the 
fans speed up to maintain the proper ambient temperature. When the temperature returns to a 
normal operating level, the fans return to their default speed.

 

Why not simply run the fans at 100% capacity all the time? For several good reasons: to reduce 
the ambient noise, reduce the wear-and-tear on the fans and reduce the server power draw. The 
reduction in ambient noise and power draw may be relatively minor for a single server, but put 
dozens or hundreds in a data center and it can make a big difference. 

In addition, the server uses 

hexagonal ventilation holes

 in the chassis. Hexagonal holes can be 

Содержание System x3620 M3 7376

Страница 1: ...ading Technology and integrated power gates and automated power management The x3620 M3 supports up to 12 DIMMs 96GB of RDIMM 1333MHz DDR3 memory and provides Chipkill ECC Error Checking and Correctin...

Страница 2: ...controller or the 6Gbps ServeRAID M1015 ServeRAID M5014 or ServeRAID M5015 controller provide high performance RAID support for SAS SATA drives Up to 8 3 5 inch hot swap SAS SATA hard disk drives offe...

Страница 3: ...l using data encryption IBM Systems Director 6 1x is included for proactive systems management IBM Systems Director comes with a portfolio of tools including IBM Systems Director Active Energy Manager...

Страница 4: ...and Intel Turbo Boost and Hyper Threading technology CTO only 40W 4 core Xeon 5600 low voltage model L5630 running at 2 13GHz with extremely low power draw and amazing performance watt only 10W per co...

Страница 5: ...able for use but also doubles the number of memory controllers thus doubling the system memory bandwidth If you add a second processor but no additional memory for the second processor the second proc...

Страница 6: ...BM Active Memory protection memory mirroring Memory mirroring works much like disk mirroring The total memory is divided into three channels a primary channel a backup channel and an unused channel Da...

Страница 7: ...tery backup included and supports RAID 0 1 10 5 50 for up to 16 drives limited by available bays to 8 The IBM ServeRAID M5000 Series Advance Feature Key adds RAID 6 60 with SED support to the ServeRAI...

Страница 8: ...SI protocol offloads By using a common infrastructure for Ethernet and storage networks data centers can reduce capital expense CapEx for adapters switches and cables and operational expense OpEx for...

Страница 9: ...upport Manager Product Customization Services and extensive technical support offerings The IBM ServerProven program provides the confidence that specific options and operating systems have been teste...

Страница 10: ...MM IBM ToolsCenter IBM Systems Director Active Energy Manager Automatic Server Restart Wake on LAN support PXE support text console redirect Predictive Failure Analysis and IBM Systems Director The In...

Страница 11: ...te Deployment Manager to take control of a system before the BIOS operating system or applications are loaded using Wake on LAN PXE and lets an administrator perform many low level tasks remotely that...

Страница 12: ...s to be treated as one logical drive ServeRAID technology also allows data to be stored redundantly across multiple hard disk drives enhancing both the integrity and the availability of the data SAS a...

Страница 13: ...nd information 13 IBM System x3620 M3 Images Front View Inside View Hot Swap 3 5 HDDs Status LEDs Optical Drive Hexagonal Ventilation Holes Power Button USB 2 0 Ports Simple Swap 3 5 HDDs Hot Swap Pow...

Страница 14: ...ard maximum 1 2 Hyper Threading Technology supported Yes 2 threads per core 42x 52x 62x plus E5640 L5630 L5640 X5670 via CTO No 22x 32x Turbo Boost Technology supported Yes 42x 52x 62x plus E5640 L563...

Страница 15: ...TB with internal tape drive 3 5 inch HS SAS 4 8TB 8 x 600GB plus internal backup drive Drive capacities supported 3 5 inch HS SATA II 250GB 500GB 1TB 2TB 7 2K 3 5 inch SS SATA II 250GB 500GB 1TB 2TB 7...

Страница 16: ...roller Yes IMM Optional systems management adapter Virtual Media Key optional Light path diagnostics support No Predictive Failure Analysis PFA support Memory HDDs and the onboard battery Power supply...

Страница 17: ...age 4 8TB of internal hot swap SAS storage High performance external expansion Five 480Mbps USB 2 0 ports two front two rear one internal for an optional tape drive IBM RDX Removable Disk Backup Syste...

Страница 18: ...Workloads Scalability Floating Point Performance Memory Throughput Integer Performance I O and Storage Density High Availability Systems Management Security Distributed Deployment x3250 M3 x3550 M3 x3...

Страница 19: ...names may be trademarks or service marks of others IBM reserves the right to change specifications or other product information without notice References in this publication to IBM products or servic...

Отзывы: