v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See the
Problem Determination and Service Guide
on the IBM
Documentation
CD to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Lit light path
diagnostics LED with
the system-error or
information LED also
lit
Description
Action
Power supply
A power supply has failed or has
been removed.
1. Check the individual power-supply LEDs.
2. Reseat the following components:
a. Power supply
b. (Trained service technician only) Power-supply
cage cables
3. Replace the following components one at a time,
in the order shown, restarting the server each time:
a. Power supply
b. (Trained service technician only) Power-supply
cage
Hard disk drive /RAID
A hard disk drive, SAS controller, or
RAID adapter error has occurred.
Notes:
1. This LED is lit also when a hard
disk drive is removed from the
server.
2. The error LED on the failing
hard disk drive is also lit.
3. Check the system-event log for
a RAID error.
1. Reinstall the removed drive.
2. Reseat the following components:
a. Failing hard disk drive
b. SAS hard disk drive backplanes
c. SAS signal and power cables
d. System board
e. ServeRAID-BR10i SAS/SATA Controller
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server each
time.
NMI
A hardware error has been reported
to the operating system.
1. See the system-error log (see the
Problem
Determination and Service Guide
on the IBM
Documentation
CD).
2. If the PCI LED is lit, follow the instructions for that
LED.
3. If the MEM LED is lit, follow the instructions for
that LED.
4. Restart the server.
Chapter 2. Installing optional devices
31
Содержание System x3500 M2 Type 7839
Страница 1: ...IBM System x3500 M2 Type 7839 Installation and User s Guide ...
Страница 2: ......
Страница 3: ...IBM System x3500 M2 Type 7839 Installation and User s Guide ...
Страница 34: ...20 IBM System x3500 M2 Type 7839 Installation and User s Guide ...
Страница 90: ...76 IBM System x3500 M2 Type 7839 Installation and User s Guide ...
Страница 108: ...94 IBM System x3500 M2 Type 7839 Installation and User s Guide ...
Страница 117: ...Korean Class A warning statement Appendix B Notices 103 ...
Страница 118: ...104 IBM System x3500 M2 Type 7839 Installation and User s Guide ...
Страница 124: ...110 IBM System x3500 M2 Type 7839 Installation and User s Guide ...
Страница 125: ......
Страница 126: ... Part Number 69Y4168 Printed in USA 1P P N 69Y4168 ...