Installing a power supply cage in a 2U chassis
To install the power supply cage in a 2U chassis, complete the following steps.
2U chassis
Power supply cage
Release latch
1. Insert the power supply cage into the rear of the chassis.
2. Slide into the chassis until the release latch clicks into place.
3. Install the 2U chassis fan assembly (see “Installing the 2U chassis fan
4. Install the 2U chassis fan-assembly top cover (see “Installing the 2U chassis
fan-assembly top cover” on page 283).
5. Install the power supply (see “Installing a power supply in a 2U chassis” on
6. Install the chassis in the iDataPlex rack (see “Installing the 2U chassis in a rack”
Removing the optional dual-port network adapter
Note:
Filler panel must be installed even if you do not install a network adapter.
To remove the network adapter, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
2. Turn off the server and peripheral devices and disconnect all power cords.
3. If the system-board tray is installed in a chassis, remove it (see “Removing the
system-board tray from a 2U chassis” on page 279).
4. If an expansion enclosure is installed on the system-board tray, remove it (see
“Removing a GPGPU enclosure” on page 281); otherwise, remove the
system-board tray cover (see “Removing the system-board tray cover” on page
280).
5. Loosen the screws and the captive screws on the network adapter from the
screw holes.
Chapter 5. Removing and replacing server components
321
Содержание System x iDataPlex dx360 M4 7912
Страница 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 399: ......
Страница 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...