10. If you are instructed to return the hard disk drive backplane, follow all
packaging instructions, and use any packaging materials for shipping that are
supplied to you.
Installing the 3U chassis hard disk drive backplane
To install the 3U chassis hard disk drive backplane, complete the following steps.
1. Touch the static-protective package that contains the hard disk drive backplane
to any
unpainted
metal surface on the outside of the 3U chassis; then, remove
the hard disk drive backplane from the package.
2. Position the hard disk drive backplane in the 3U chassis and secure it with 10
screws.
3. Install the power-supply paddle card and power supply (see “Installing a power
supply in a 3U chassis” on page 176).
4. Install the system-board tray in the 3U chassis (see “Installing the system-board
tray in a 3U chassis” on page 129).
5. Install the fan assembly (see “Installing the 3U chassis fan assembly” on page
6. Install the storage-riser-card assembly and ServeRAID SAS controller (see
7. Install the top cover (see“Installing the 3U chassis top cover” on page 137 ).
8. Install the 3U chassis in the iDataPlex rack (see “Installing a 3U chassis in a
Type 7825 iDataPlex rack” on page 191).
Chapter 5. Removing and replacing server components
189
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...