background image

Help and service

In the US or Canada, you can call 1 (800) IBM SERV for help and service. You
must choose the software or hardware option when you call for assistance. Before
you call for support, be sure to have your Software Customer Number available.

Choose the software option if you are uncertain whether the problem involves the
TS7620 Appliance Express

®

hardware. Choose the hardware option only if you are

certain the problem solely involves the TS7620 Appliance Express hardware.

When you call IBM for service for the TS7620 Appliance Express follow these
guidelines for the software and hardware options:

Software option

Identify the TS7620 Appliance Express as your product and supply your
customer number as proof of purchase. The customer number is a
seven-digit numeric code (0000000 - 9999999) assigned by IBM when the
PID is purchased. It is on your customer information worksheet or on the
invoice from the software purchase.

Note:

If asked for an operating system, say "Storage".

CAUTION:
If you supply an incorrect customer number, you might be denied
support for your software. Keep track this important information at the
time of purchase.

Hardware option

Provide the four-digit machine type and the product serial number for the
hardware component that is exhibiting a problem. For example: 3959 78
00001.

Getting help online

Be sure to visit the support page for the IBM System Storage TS7600 with
ProtecTIER. The page contains FAQs, parts information, technical hints and tips,
technical publications, and downloadable files (if applicable). The URL for the page
is:

http://www.ibm.com/servers/storage/support/tape.

For more websites, see “Websites” on page 3.

Before you call for service

Some problems can be solved by referring to the electronic or printed
documentation that comes with the TS7620 Appliance Express, or visiting the
support web page. Be sure to also read the information in any readme files and
release notes that come with the product.

Getting help by telephone

With the original purchase of the TS7620 Appliance Express, ProtecTIER V3.3.2,
you have access to extensive support coverage. During the product warranty
period, you can call the IBM Support Center (1-800-426-7378 in the US) for product
assistance that is covered under the terms of the hardware IBM warranty or the
software maintenance contract that comes with product purchase.

2

Increasing Capacity on the 3959 SM2 (Feature Code 9317)

Содержание System Storage ProtecTIER TS7620

Страница 1: ...IBM System Storage TS7620 ProtecTIER Deduplication Appliance Express V3 3 2 Increasing Capacity on the 3959 SM2 from 6 TB to 12 TB Feature Code 9317 GA32 2222 03 ...

Страница 2: ...uplication Appliance Express V3 3 2 and to all subsequent releases and modifications until otherwise indicated in new editions Copyright IBM Corporation 2012 2013 US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp ...

Страница 3: ...ProtecTIER V3 3 Service menu 23 Prepare the 3959 SM2 server 23 Upgrade the server capacity 23 Configure the increased capacity 25 Accessibility for publications and ProtecTIER Manager 29 About the Windows based accessibility features 29 About the Java based tools 30 Installing the Java Runtime Environment 30 Installing the Java Access Bridge 31 Using a screen reader to install ProtecTIER Manager 3...

Страница 4: ...iv Increasing Capacity on the 3959 SM2 Feature Code 9317 ...

Страница 5: ...ion about IBM products and services and find the latest technical information For more information see Table 1 Table 1 IBM websites for help services and information Description World Wide Web address URL IBM home page http www ibm com Directory of worldwide contacts http www ibm com planetwide Support for IBM System Storage and TotalStorage products http www ibm com storage support The IBM Suppor...

Страница 6: ...rtant information at the time of purchase Hardware option Provide the four digit machine type and the product serial number for the hardware component that is exhibiting a problem For example 3959 78 00001 Getting help online Be sure to visit the support page for the IBM System Storage TS7600 with ProtecTIER The page contains FAQs parts information technical hints and tips technical publications a...

Страница 7: ...p to date information about your product including documentation and the most recent downloads can be found at the following websites v The translated publications for this product are included with the product These documents and product specification sheets are also available from the following website http www 947 ibm com systems support supportsite wss brandmain brandind 5345868 v http www ibm...

Страница 8: ...or accessibility information go to the following website http www 03 ibm com able product_accessibility index html v For the latest information about product recycling programs go to the following website www ibm com ibm environment products prp shtml Estimated time for increasing the capacity of the TS7620 Appliance Express ProtecTIER V3 3 2 The estimated time for this procedure is 30 minutes 4 I...

Страница 9: ...rver is at the correct code level and size to increase the storage capacity About this task This task must be completed before you increase the storage capacity of the 3959 SM2 server Procedure To verify that theProtecTIER level is at the correct code level on the server and that the system is the correct size for increasing the capacity perform the following steps 1 Log in to the system with user...

Страница 10: ...acity on the 3959 SM2 from 6TB to 12TB Feature Code 9317 This document is found on the IBM Publications Center website http www ibm com e business linkweb publications servlet pbi wss If you want to upgrade the server to ProtecTIER v3 3 before you increase the storage capacity see the instructions in the IBM System Storage TS7610 and TS7620 ProtecTIER Deduplication Appliance Express Software Upgra...

Страница 11: ... back of the 3959 SM2 server Upgrade the server capacity Before you begin The following procedures assume that the server is running ProtecTIER V3 3 2 or higher For more information see Chapter 2 Prerequisites for the TS7620 Appliance Express ProtecTIER V3 3 2 on page 5 Complete the Prepare the 3959 SM2 server procedure before you upgrade the server capacity Ensure you install from DVD or download...

Страница 12: ...tray and press Enter b After the disk mounts the code package is extracted Mounting done Extracting the code package c After the system extracts the new code package the following output displays Copying files Copied 100 Done d If a previous code package exists the following message displays There are 1 older packages on the system Would you like to clear them y n Type y and press Enter When the m...

Страница 13: ...ade package Done Checking prerequisites conditions for package Done Going to upgrade to package mnt cdrom PT_MD5_TS7620_23TB_V3 3 90 0 full x86_64 tar build 7133 086 version 3 release 3 minor 86 fix 0 Upgrade method SEQUENTIAL Do you want to continue yes no yes Calling Upgrade Process Done Upgrade called successfully 5 When the restart is complete the increased capacity is installed Important Foll...

Страница 14: ...TIER services only including GFS 5 Stop VTFD service only 6 Poweroff This Node 7 Reboot This Node B Back E Exit Your choice 3 If all services are running the output displays Begin Processing Procedure Service Status cman UP clvmd UP gfs UP vtfd UP ptrasd UP End Processing Procedure Successfully Press ENTER to continue If all the services are UP continue to step 4 to configure the increased capacit...

Страница 15: ...ss Enter when the Would you like to stop the VTFD service yes no message displays 10 When the configuration starts these messages display Stopping services please wait Stopping Cluster Services Done Services stopped Checking installed applications Done Checking conditions Checking BOM Done Disable MegaRAID Bios Done Disable MegaRAID PD Fail History Done Checking for existing nodes Done Checking NI...

Страница 16: ...rease is complete the following message displays upgrade ended successfully End Processing Procedure Successfully Your 3959 SM2 server now has 12 TB of storage capacity 12 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...

Страница 17: ...ontact your IBM Sales Representative to order the v IBM System Storage ProtecTIER Appliance Edition V3 3 DVD or v IBM System Storage ProtecTIER Enterprise Edition V3 3 DVD or v see Downloading ProtecTIER version 3 3 2 on page 14 for instructions about how to download ProtecTIER software and fixes Upgrade ProtecTIER 3 1 8 or higher to version 3 3 2 using ProtecTIER Manager version 3 3 2 Upgrading t...

Страница 18: ...e ProtecTIER version Verify that the fix update you are applying is a later version than the currently installed version 6 Continue on to Downloading ProtecTIER version 3 3 2 Downloading ProtecTIER version 3 3 2 Use these procedures to download ProtecTIER version 3 3 2 from the IBM website if you did not obtain the IBM System Storage ProtecTIER Appliance Edition V3 3 DVD or the IBM System Storage ...

Страница 19: ... Edition downloads You might need to hover the mouse over the link to get the full text of the link to appear The Select fixes page opens 8 From the Results list click the most recent entry such as v3 3 x for the product you specified where v3 3 x is the most current version of ProtecTIER version 3 3 2 available for download The Download options page is displayed 9 In the Download Options box clic...

Страница 20: ... display any systems This is normal The systems will display after you log in and the column headings in the All systems view will change after you log in You will be instructed when to log in later in this procedure Note For a more detailed explanation of the All systems view see the IBM System Storage TS7600 with ProtecTIER User s Guide for VTL Systems IBM System Storage TS7600 with ProtecTIER V...

Страница 21: ...rt one of the following DVD ROMs into the CD DVD ROM drive on which you are using the ProtecTIER Manager IBM System Storage ProtecTIER Entry Edition Capacity 1 3959 SM2 6 TB DVD IBM System Storage ProtecTIER Entry Edition Capacity 2 3959 SM2 12 TB DVD IBM System Storage ProtecTIER Entry Edition Capacity 3 3959 SM2 23 TB DVD Chapter 3 Upgrading the ProtecTIER software to version 3 3 from version 3 ...

Страница 22: ... ProtecTIER server b Ensure that you copy the file to the install new directory to either v The ProtecTIER server you are upgrading or v The directory on your computer Note In a clustered system the code upgrade package is copied on the first node then is copied to the second node automatically c If you are prompted for a password for root access type admin scp ProtecTIER package tar root ProtecTI...

Страница 23: ...grade display v Yes Select the name of the code upgrade package and click OK then go to the next step Otherwise go to the No branch v No Click Browse then navigate to the directory to where you placed the code upgrade package then click OK Figure 1 Selecting the upgrade package from the DVD Chapter 3 Upgrading the ProtecTIER software to version 3 3 from version 3 2 x or higher using ProtecTIER Man...

Страница 24: ...0 minutes for the code upgrade package to install a Monitor the progress bar periodically To view the progress ensure that you have selected the tab for Upgrading systems b Note that during the code upgrade that services will stop and that the system will reboot automatically ts761422 Figure 2 Browsing to the code upgrade package on your hard drive 20 Increasing Capacity on the 3959 SM2 Feature Co...

Страница 25: ...plete 16 To confirm that you upgraded the ProtecTIER to the correct version click the name of the system for which you performed the upgrade then locate the words and link for Version Chapter 3 Upgrading the ProtecTIER software to version 3 3 from version 3 2 x or higher using ProtecTIER Manager 21 ...

Страница 26: ...elease version of the code theProtecTIER model Linux RPM version DTC Emulex RPM version ProtecTIER Replication Manager Version machine type model and machine serial number click the link for Version 22 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...

Страница 27: ...nfig and password ptconfig The ProtecTIER Service menu opens 4 If the DVD drive that came with the server is not attached attach it to the USB port at the back of the 3959 SM2 server Upgrade the server capacity Before you begin The following procedures assume that the server is running ProtecTIER V3 3 2 or higher For more information see Chapter 2 Prerequisites for the TS7620 Appliance Express Pro...

Страница 28: ...ays put the ProtecTIER code disk in the DVD tray close the tray and press Enter b After the disk mounts the code package is extracted Mounting done Extracting the code package c After the system extracts the new code package the following output displays Copying files Copied 100 Done d If a previous code package exists the following message displays There are 1 older packages on the system Would y...

Страница 29: ...package Done Checking prerequisites conditions for package Done Going to upgrade to package mnt cdrom PT_MD5_TS7620_23TB_V3 3 90 0 full x86_64 tar build 7133 086 version 3 release 3 minor 86 fix 0 Upgrade method SEQUENTIAL Do you want to continue yes no yes Calling Upgrade Process Done Upgrade called successfully 5 When the restart is complete the increased capacity is installed Important Followin...

Страница 30: ...y including GFS 5 Stop VTFD service only 6 Poweroff This Node 7 Reboot This Node B Back E Exit Your choice 3 If all services are running the output displays Begin Processing Procedure Service Status cman UP clvmd UP gfs UP vtfd UP ptrasd UP End Processing Procedure Successfully Press ENTER to continue If all the services are UP continue to step 4 on page 10 to configure the increased capacity If s...

Страница 31: ...Enter when the Would you like to stop the VTFD service yes no message displays 10 When the configuration starts these messages display Stopping services please wait Stopping Cluster Services Done Services stopped Checking installed applications Done Checking conditions Checking BOM Done Disable MegaRAID Bios Done Disable MegaRAID PD Fail History Done Checking for existing nodes Done Checking NICs ...

Страница 32: ...rease is complete the following message displays upgrade ended successfully End Processing Procedure Successfully Your 3959 SM2 server now has 12 TB of storage capacity 28 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...

Страница 33: ... with limited vision use the ProtecTIER Manager installation wizard and software After preparing the ProtecTIER Manager workstation for accessibility you can use Windows based screen reader software and a digital voice synthesizer to hear what is displayed on the screen The installation configuration and instructional screens in the Windows versions of the ProtecTIER Manager installation wizard an...

Страница 34: ...r your computer to run Java based applications Procedure 1 Go to http www java com The Java website opens The java com website auto detects the operating system and Internet browser of the computer you use when you access the site 2 Click Free Java Download and proceed as appropriate v If the Download Java for Windows page opens go on to step 3 v If the Download Java for page title contains the na...

Страница 35: ...ibility page of the Oracle website opens 2 Read the information provided then click Access Bridge 3 Scroll down to the Java Access Bridge for Microsoft Windows Operating System x x x where x x x is the most recent version listed section Click the Download Java Access Bridge x x x link The Software License Agreement page opens 4 Read the license agreement and then select the I agree to the Software...

Страница 36: ... spaces or quotation marks Any deviation in the procedure can cause the installation to start in the non accessible mode or fail completely Procedure 1 If your workstation is configured to automatically open DVDs temporarily disable the Windows AutoPlay feature for the CD DVD device Use the Windows Help or other Windows documentation for instructions and then go on to step 2 2 Insert the IBM Syste...

Страница 37: ... color palette resume your regular use of ProtecTIER Manager v To change the contrast mode for ProtecTIER Manager go to Enabling the Windows High Contrast option To customize the color palette go to Customizing the color palette on page 37 Enabling the Windows High Contrast option About this task To make it possible for ProtecTIER Manager display in high contrast you must first enable the Use High...

Страница 38: ...4 Click Settings The Settings for High Contrast dialog box displays as shown in Figure 4 on page 35 Figure 3 Display tab 34 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...

Страница 39: ...f available color schemes b Select the high contrast scheme that you want to use c Click Ok to close the Settings for High Contrast dialog box d Click Ok to close the Accessibility Options dialog box After a few moments the display changes to the new color scheme e Go on to Using the Windows high contrast scheme with ProtecTIER Manager Using the Windows high contrast scheme with ProtecTIER Manager...

Страница 40: ...r window opens as shown in Figure 5 2 On the toolbar click Tools Preferences The Preferences dialog box opens with the Appearance tab selected as shown in Figure 6 Figure 5 ProtecTIER Manager window ts760879 Figure 6 Preferences dialog box 36 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...

Страница 41: ...to Customizing the color palette v If you do not want to customize the color palette resume your regular use of ProtecTIER Manager Customizing the color palette About this task Use this procedure to customize the color palette for ProtecTIER Manager to improve visibility in the display or to suit your personal preferences Procedure 1 If necessary start ProtecTIER Manager as described in step 1 on ...

Страница 42: ...earance tab 6 To change another color repeat steps 3 on page 37 through 5 7 When you are finished making changes in the Appearance tab click Ok You are returned to the ProtecTIER Manager window 8 Exit and restart ProtecTIER Manager as described in step 4 on page 37 so the color palette changes take effect After you log in to ProtecTIER Manager and add a node the display reflects your custom color ...

Страница 43: ...e Return to the task from which you were sent to these instructions or resume your regular use of ProtecTIER Manager ts760882 Figure 9 Default color versus custom color Accessibility for publications and ProtecTIER Manager 39 ...

Страница 44: ...40 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...

Страница 45: ...THER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to th...

Страница 46: ...tions To illustrate them as completely as possible the examples include the names of individuals companies brands and products All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental Trademarks The following terms are trademarks of the International Business Machines Corporation in the United States other countr...

Страница 47: ... others Electronic emission notices This section contains the electronic emission notices or statements for the United States and other regions Federal Communications Commission statement This explains the Federal Communications Commission s FCC statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limit...

Страница 48: ...t cause radio interference in which case the user might be required to take adequate measures Responsible Manufacturer International Business Machines Corp New Orchard Road Armonk New York 10504 914 499 1900 European community contact IBM Deutschland GmbH Technical Regulations Department M372 IBM Allee 1 71139 Ehningen Germany Tele 49 7032 15 2941 e mail lugi de ibm com Australia and New Zealand C...

Страница 49: ...e elektromagnetische Verträglichkeit von Geräten EMVG Dies ist die Umsetzung der EU Richtlinie 2004 108 EG in der Bundesrepublik Deutschland Zulassungsbescheinigung laut dem Deutschen Gesetz über die elektromagnetische Verträglichkeit von Geräten EMVG bzw der EMC EG Richtlinie 2004 108 EG für Geräte der Klasse A Dieses Gerät ist berechtigt in übereinstimmung mit dem Deutschen EMVG das EG Konformit...

Страница 50: ...tion This topic contains the product service contact information for Taiwan IBM Taiwan Product Service Contact Information IBM Taiwan Corporation 3F No 7 Song Ren Rd Taipei Taiwan Tel 0800 016 888 Japan Voluntary Control Council for Interference VCCI Class A Statement 46 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...

Страница 51: ...tion Technology Industries Association JEITA Statement less than or equal to 20 A per phase Korean Communications Commission KCC Class A Statement Russia Electromagnetic Interference EMI Class A Statement jjieta1 rusemi Notices 47 ...

Страница 52: ...48 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...

Страница 53: ...tion wizard enabling screen reader compatibility 29 preparing for accessibility 29 ProtecTIER v3 1 8 x downloading from IBM web site 14 ProtecTIER v3 1 x x applying fixes 14 ProtecTIER v3 3 downloading from IBM web site 16 upgrade 16 upgrading 16 purpose 1 R RAM required 5 requirements 5 resources websites 3 S service 1 software level 5 system administrators 1 system level 5 T Trademarks 42 U upda...

Страница 54: ...50 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...

Страница 55: ... For technical questions and information about products and prices please contact your IBM branch office your IBM business partner or your authorized remarketer When you send comments to IBM you grant IBM a nonexclusive right to use or distribute your comments in any way it believes appropriate without incurring any obligation to you IBM or any other organizations will only use the personal inform...

Страница 56: ... Storage Information Development IBM Corporation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 57: ......

Страница 58: ... Part Number 39U3474 Printed in USA GA32 2222 03 1P P N 39U3474 ...

Отзывы: